Download Print this page

Panasonic SF4D-*-01 Series Quick Instruction Manual page 5

Safety light curtain type 4
Hide thumbs Also See for SF4D-*-01 Series:

Advertisement

● Basic wiring
(Pink) Test input
Gray cable
(Brown) +V
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
Gray cable (with black line)
*S1
Switch S1
• Test input
Vs to Vs ‒ 2.5V (sink current 5mA or less): Emission halt, Open: Emission (Note)
Note: Vs is the supply voltage.
<Reference>
K1, K2: Safety relay unit, etc.
<Using NPN output>
● I/O circuit diagrams
Emitter
(Brown) +V
(Pale blue) Output polarity setting / Lockout release input
6.8kΩ
470Ω
0.1µF
(Pink) Test input
6.8kΩ
(Blue) 0V
Internal circuit
Users' circuit
Receiver
(Brown) +V
(Pale blue) Output polarity setting / Lockout release input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Blue) 0V
Internal circuit
Users' circuit
● Basic wiring
(Pink) Test input
Gray cable
(Brown) +V
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
Gray cable (with black line)
*S1
Switch S1
• Test input
0 to +2.5V (source current 5mA or less): Emission halt, Open: Emission
<Reference>
K1, K2: Safety relay unit, etc.
Using line synchronization setting and 8-core cable
<Using PNP output>
● I/O circuit diagrams
+
Emitter
K1
+
K2
Receiver
+
*S1
<Reference>
K1, K2: External device (forcible guide relay or magnetic contactor)
K1
K2
● Basic wiring
+
+
-
K1
+
K2
-
Interlock function
External device monitor function
Auxiliary output
<Reference>
K1, K2: Safety relay unit, etc.
*S1
Switch S1
• Test / Reset input
Manual reset ...Vs to Vs ‒2.5V (sink current 5mA or less): Emission halt (Note), Open: Emission
Auto reset ...Vs to Vs ‒2.5V (sink current 5mA or less): Emission (Note), Open: Emission halt
• Interlock setting input, External device monitor input
Vs to Vs ‒2.5V (sink current 5mA or less): Valid (Note), Open: Invalid
Note: Vs is the supply voltage.
(Brown) +V
6.8kΩ
470Ω
(Pale purple) Interlock setting input
0.1µF
6.8kΩ
470Ω
6.8kΩ
(Pink) Test / Reset input
0.1µF
6.8kΩ
(Red) Auxiliary output
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
Internal circuit
Users' circuit
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Brown) +V
6.8kΩ
470Ω
(Pale purple) External device monitor input
0.1µF
6.8kΩ
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
Internal circuit
Users' circuit
(Pale purple) Interlock setting input
(Brown) +V
(Pink) Test / Reset input
Gray cable
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Red) Auxiliary output
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Pale purple) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
Gray cable
(with black line)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
Invalid (auto reset)
Invalid
Cannot be used
*S1
*S1
+
Load
K1 K2
K1
K2
+
-
K1
K2

Advertisement

loading

This manual is also suitable for:

Sf4d-f*-01 seriesSf4d seriesSf4d-a*-01 seriesSf4d-h*-01 series