Via Benini, 1 - 40069 Zola Predosa BOLOGNA - ITALY Declares that: Operator mod. 412 is built to be integrated into a machine or to be assembled with other machinery to create a machine under the provisions of Directive 98/37/EC;...
Page 3
INSTALLATION DIMENSIONS These instructions apply to the following models: Operators 412 and 412-24V The FAAC 412 AUTOMATION SYSTEM for swing gates comprises two electromechanical operators which drive the gate leaves by means of a worm screw. The system locks mechanically; therefore no electric lock is required.
Page 4
(fig. 6). 9) Fix the front bracket temporarily to the leaf by two welds. Operators 412 N.B.: If the gate frame does not allow for secure fixing of Photocells the bracket, add a support plate.
(see relative paragraph). Safety devices installed on the plant must be checked every six months. 9. REPAIRS For repairs, refer to authorised FAAC service centres. Fig. 9...
Page 6
A few simple rules should be followed to prevent accidental The 412 automation system is also equipped with an anti- problems. crushing safety device (fitted as standard) that limits the - Do not pass between the leaves when they are still moving: torque transmitted to the leaves.
Page 8
Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. FAAC se réserve le droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant les caractéristiques essentielles, sans devoir pour autant mettre à...