7-3-3

System functions

System functions
The inverter system, repair and maintenance functions as well as function blocks for operation setting of the control panel are described
as follows.
Copy function
F1601
The inverter system, repair and maintenance functions as well as function blocks for operation setting of the control panel are described
as follows.
Code No.
Function Name
F1601
Copy function
● Transfer the current function code data to the operation panel, and then to the host of copying side. When copying, "
flashing "
" will be displayed on 7-segment monitor.
● To transfer data to the host of copying side, turn the power OFF before transmission in order to re-close the inverter to reset.
● When the motor parameters are set by F5001 - F5016, the copy function can not be used. Because during replication, if the motor
parameters conflicts with the set value of other function code(s), the motor parameters or the conflicted function code(s) will be
initialized. When motor parameters are set by F5009 - F5014, set F1601 = 3 to transfer data to the host.
● When the motor parameters are set by F5001 - F5016, the copy function can not be used. Because during replication, if the motor
parameters conflicts with the set value of other function code(s), the motor parameters or the conflicted function code(s) will be
initialized. When motor parameters are set by F5009 - F5014, set F1601 = 3 to transfer data to the host.
(Sequence) Sequence for copying to other inverter(s).
1 Transfer the current function code data to the operation panel with F1601=1. Refer to the sequence of 5-5-1.
2 During transmission of data, the flashing "
3 Turn the power OFF, remove the operation panel and install it to other host. Please also turn OFF the power of other hosts before
work.
4 Turn ON the power of other hosts.
5 Transfer data from the operation panel to other hosts with F1601 = 2.
6 During transmission of data, the flashing "
7 After the transmission of data to the copy side and before operation, turn the power OFF to reset inverter.
● As an exception, the active codes and data of F1320, F1601, F1602, F1604, all of F18XX blocks, all of F33XX blocks, F5001 -
F5008, F5015, F5016, F6010 - F6016, F6117, F6118, as well as optional functions can not be copied. And, in case of copy between
different inverter capacities and rated voltages, the data may not be copied depending on its contents. (e.g.: F1005)
● The copy function can not be used during operation of the inverter. Please stop the inverter before copying.
Note 1: Since copy function is subject to software version, data may not be copied due to compatibility of the software version.
* For upgrade, please contact the sales shops.
Note 2: In the event of an error during data transmission to operation panel, please do not transfer data to the same or any other
inverter.
Note 3: During action of copy function, the monitor's display flashes. When the monitor's display is flashing, do not pull out or
insert the operation panel nor turn off the power.
Note 4: During action of copy function, no part of the operation panel can be operated.
Note 5: This code can not be written using communication function. The undefined response shall be returned.
Note 6: When the inverter host capacity of the copying side is different and F1601 = 3, conflict and interference errors may occur if
the data is transferred from the panel to the host. When using F1601 = 3 for a copy of motor parameters, check if the
inverter capacities of the copying source and copying side are the same.
Data Content
0:No function
Transfer the current code data to the operation
1:
panel
2:
Transfer the contents stored by operation panel
to the inverter
(Excluding motor parameters
measured )
3:
Transfer the contents stored by operation panel
to the inverter
(Including motor parameters
measured )
" is displayed. Please wait for the display of
" is displayed. Please wait for the display of
- 100 -
Setting Resolution
Factory Presets
1
0
until it disappears.
until it disappears.
"or a