  • Page 1 Mira Decor 8.5kW, 9.5kW and 10.8kW Electric Shower For SPARES, ADVICE or REPAIRS please call us free on 0800 001 4040 (UK only) Installation and User Guide These instructions must be left with the user 1365393-W2-A...
  • Page 2 Important Safety Information WARNING - This shower can deliver scalding temperatures, cause fire, electric shock or other personal injury if not operated, or maintained in accordance with the instructions, warnings and cautions contained in this guide and on the appliance. Please read the important safety information and the operation section of this guide before using the shower.
  • Page 3 9. Installation of the shower must be carried out in accordance with these instructions by qualified, competent personnel. Read all instructions before installing the shower. 10. DO NOT switch the shower on if water starts leaking from the shower case. Isolate the electrical supply to the shower immediately. 11.
  • Page 4 22. DO NOT connect the outlet of the shower to any tap, control valve, trigger operated handset or showerhead other than those specified for use with this shower as the outlet acts as a vent for the tank body. Only Kohler Mira recommended accessories should be used. 23. DO NOT perform any unspecified modifications, or drill or cut holes in the product other than instructed by this guide. When servicing only use genuine Kohler Mira replacement parts.
  • Page 5 Pack Contents Electric Shower 3 x Screws 3 x Wall Plugs 1 x Electric Shower 1365393-W2-A...
  • Page 6 Shower Fitting 1 x Cap 2 x Slide Bar Support 2 x Mounting Pack 1 x Showerhead Multimode 1 x Clamp Bracket 1 x Slide Bar 1 x Shower Hose 2 x Hose Seal 1 x Soap Dish 1365393-W2-A...
  • Page 7 Dual Shower Fitting 2 x O-rings (2 as spare) 2 x Grubscrew (1 as spare) 1 x Riser Arm 1 x Wall Fixing 1 x Overhead 1 x Middle Bar 1 x Clamp Bracket 1 x Hose Retaining Ring 1 x Showerhead Single Mode 1 x Lower Bar 1 x Diverter Assembly 1 x Shower Hose 2 x Hose Seal...
  • Page 8 Products manufactured by Kohler Mira Ltd are designed to be safe, provided that they are installed, used and maintained in good working order, in accordance with our instructions and recommendations.
  • Page 9 Specifications Dimensions Height 332 mm Width 220 mm Depth 73.5 mm (97.4 mm including Dials) Variant Plumbing 8.5 kW 9.5 kW 10.8 kW Minimum Dynamic Pressure 70 kPa (0.7 bar) 100 kPa (1.0 bar) Maximum Dynamic Pressure 500 kPa (5.0 bar) Maximum Static Pressure 1000 kPa (10.0 bar) Minimum Static Pressure...
  • Page 10 Eco-Design/Energy Labelling Product Information Indicative annual electricity consumption (kWh), based upon 2100 Wh daily water energy demand. Actual electricity consumption will depend on kW rating and the duration and frequency of use. Mira Decor 8.5 kW 9.5 kW 10.8 kW Load Profile...
  • Page 11 Installation Requirements Plumbing 1. The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice specified by the local water supply company. 2. DO NOT install the product in a position in which service access is limited. 3.
  • Page 12 17. DO NOT perform the electrical installation until the plumbing has been completed and checked for leaks. 18. T he position of the shower and shower fittings must provide a minimum gap of 25 mm between the showerhead and the spill over level of any bath, shower tray or basin and a minimum gap of 30 mm between the showerhead and the spill over level of any toilet, bidet or other appliance with a Fluid Category 5 backflow risk.
  • Page 13 Electrical 1. The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company. 2. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
  • Page 14 Install the Shower Warning! Isolate the electrical and water supplies before installing the shower. Ceiling 100 mm 300 mm 700 mm 1894.017 1894.018 Diverter Hose Diverter Hose (0.6 m) (1.0 m) If the diverter is positioned outside of the light grey area as shown in the diagram a longer link hose is available up to 1.0 m max in length.
  • Page 15 Remove the three screws that hold the cover Screws on and remove the cover. Remove the bungs. Use the installation template provided, level and mark the positions of the three fixing holes. Drill three holes to suit the fixing screws and Bung wall plugs. Caution! DO NOT drill into cables or pipes in the wall. Bung Cover Note: Ensure that there are sufficient Screw lengths of supply pipe and electrical...
  • Page 16 Check the inlet filter is in position before connecting inlet supply. Connect the inlet supply pipe to the inlet connector using a push fit elbow or an elbow with compression nuts and olives. Important! DO NOT use push fit elbows that require specialist tools for removal. Access to the inlet filter Inlet Filter is required periodically and so any connector needs to easily removed for...
  • Page 17 The cover has thinned sections that can be removed to allow entry of the supply pipe and electrical cables. Remove the top thinned section of the case for a falling supply, or remove the bottom thinned section for a rising supply. If the electrical cables enter from above or below, remove an additional thinned section for the electrical cable.
  • Page 18 Install the Shower Fittings Mira Decor Single Outlet Ø  8   m m Ø  8   m m We recommend that the slide bar is installed with the ends flush. Mark the wall fixing positions and drill two holes to suit the wall fixings. Caution! Do not drill into cables or pipes in the wall.
  • Page 19 Insert the wall plugs and fix the mounting brackets and secure with the wall screws. Note: Check for vertical alignment before tightening. The mounting brackets are slotted to aid this alignment. Then fully tighten. Install the clamp bracket and the slide bar supports to the slide bar. Make sure that the wall screws are flush with the inside edge of the mounting brackets.
  • Page 20 Install the slide bar assembly onto the mounting brackets. Tighten the 2 x M4 screws with the supplied 3 mm hexagonal key. Caution! DO NOT force assembly on to the mounting brackets, re-align a slide bar support if required. Install the end cap at top and the soap dish at bottom.
  • Page 21 Mira Decor Dual Outlet 8 mm Refer to Install the Shower on page 15 for positioning of the shower fitting and diverter. Important! DO NOT allow the overhead or handset spray water directly on to the electric shower. The overhead and handset must be positioned so this does not occur.
  • Page 22 Slide the diverter partially over the wall plate ensuring the notches in the diverter Notch lines up with the notches on the wall plate and fix temporarily in place. Notch Notch Notch Fit the clamp bracket and hose retaining ring onto the middle bar, then screw into the lower bar. Loosely fit the wall bracket into the middle bar arm with the grubscrew hole at the top.
  • Page 23 Drill the holes for the wall fixing bracket. Insert the wall plugs and fix the bracket to the wall using the screws supplied. 8 mm Loosely fit the concealing cover onto the middle bar. Ensure the lower bar is fitted correctly. Fit the middle bar onto the wall fixing bracket and tighten the grubscrew with a 2.5 mm hex key. Fit the concealing cover over the bracket. Slide the diverter over the wall plate ensuring the notches in the diverter lines up with the notches on the wall plate and fix in place using the screw supplied.
  • Page 24 Angle the riser arm to the centre of the showering area and secure in place using the grubscrew. Note: A spare grubscrew is supplied if damaged during installation. Rotate the middle port of diverter to suit position of the shower unit. Connect the diverter link hose to the diverter and the shower unit.
  • Page 25 POWER Commissioning POWER HIGH TEMPERATURE POWER Turn temperature control to the cold Turn power control to Low. position. TEMPERATURE POWER Switch on the electrical supply. Push START/STOP button. TEMPERATURE COLD 0 - 15 secs TEMPERATURE Slowly turn the temperature control Water flows freely within a few seconds, POWER to the hot position.
  • Page 26 HIGH 5 - 10 secs COLD POWER 0 - 15 secs Temperature will rise slightly. Turn power control to Eco. HIGH 5 - 10 secs POWER COLD POWER 0 - 15 secs TEMPERATURE Turn power control to High. Temperature will rise further. POWER TEMPERATURE TEMPERATURE...
  • Page 27 Note: A slight hissing sound may be heard from the shower during operation. High mains water pressure and high shower temperatures will affect the tone. This is quite normal in use. POWER User Operation Mira Decor Read the section “Important Safety Information” first. TEMPERATURE Switch on the electrical supply. Push START/STOP button.
  • Page 28 POWER HIGH POWER TEMPERATURE Turn power control to the desired Adjust temperature as required. position. COLD TEMPERATURE POWER Allow 10 - 15 secs for any temperature Check water temperature before adjustments to stabilise and reach the entering shower. showerhead. TEMPERATURE Push START/STOP button. Shower Switch off the electrical supply.
  • Page 29 A small amount of water may continue to drain/drip from the overhead shower or handset shower until the head is empty. ALWAYS switch the shower off at the electrical isolating switch when not in use. This is recommended with all electrical appliances. Warning! Turning the shower off and back on during showering may result in unstable temperatures at the showerhead.
  • Page 30 Diverter - Mira Decor Dual Outlet The diverter lever operates as shown above: Control Lever Position 1 - Water comes out of the showerhead. Control Lever Position 2 - At this point water will come out of both the overhead and the showerhead. However this is not recommended as there will be insufficient water flow.
  • Page 31 User Trouble Shooting If the malfunction has not been detailed in the fault finding table or it was not possible to correct the malfunction, professional assistance may be required. Symptom Possible Cause Possible Remedy Switch on the electrical supply via the Isolator switch in the off position pull cord or wall mounted switch Shower fails to operate Fuse blown or MCB/RCD tripped, Renew the fuse or reset the MCB/RCD.
  • Page 32 Symptom Possible Cause Possible Remedy Showerhead blocked. Remove and descale Showerhead. Hose kinked or blocked. Check hose and replace if necessary. Other outlets (e.g. Toilet, garden hose, washing machine, etc.) Turn off other appliances whilst shower drawing water while the shower is is in use. being used The incoming water supply stop Low or no flow Open the stop/isolating valve valves, or the appliance isolating...
  • Page 33 Cleaning Cleaning the Showerhead Many household and commercial cleaners, including hand and surface cleaning wipes contain abrasives and chemical substances that can damage plastics, plating and printing and should not be used. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth. Important! Keeping the showerhead clean and free from limescale will ensure that your shower and showerhead continue to perform to their maximum.
  • Page 34 Servicing Warning! There are no user serviceable parts inside the shower. Servicing of the shower must only be carried out by qualified, competent personnel following the instructions provided in this guide and those provided with any spare part. Cleaning the Inlet Filter Screws Warning! Isolate the electrical and water supplies before removing the...
  • Page 35 Remove the filter and rinse under a running tap to remove any lodged particles. Refit the inlet filter. Refer to the Installation Section for pipework reconnection or refitting the shower to the wall. Connect the shower hose. Note: Ensure the hose washer is fitted inside the hose. Follow the steps detailed in section: ‘COMMISSIONING’ to prepare the shower for use.
  • Page 36 Spare Parts 1788.429 On / Off Switching Assembly 1746.436 Thermal Switch 1788.426 (8.5kW) 1788.427 (9.5kW) 1788.428 (10.8kW) Heater Tank Assembly 1788.435 Inlet Filter 1788.433 1788.430 1788.434 Valve Clamp Terminal Block Solenoid Coil Assembly 1788.431 Outlet Connector 1789.085 Latching Switch 1894.020 Cover - Warm Silver 1894.021 Cover - White...
  • Page 37 1703.196 1740.595 Slide Bar Support (x2) 1703.194 Mounting Pack 1740.369 1703.203 Showerhead Clamp Bracket Multimode 632.73 Hose Seal (x2) 1746.599 Slide Bar (660 mm) 1844.022 Shower Hose (1.25 m) 1703.197 Soap Dish 1365393-W2-A...
  • Page 38 1894.011 Riser Arm (Riser Bar Module) 1894.033 Overhead 1894.016 Overhead 1736.733 Seal Wall Fixing 1894.011 Middle Bar (Riser Bar Module) 1703.351 Showerhead Single Mode 1703.199 1703.203 Hose Retaining Clamp Bracket Ring 1894.034 Short Lower Bar 1894.017 Diverter Hose (0.6 m) 632.73 1894.018 Hose Seal (x2) Diverter Hose (1.0 m) 632.73 1894.011 Hose Seal (x2)
  • Page 39 Notes 1365393-W2-A...
  • Page 40 ed by persons not authorised by TMV3 healthcare schemes E-mail: ● Accidental or wilful damage. CustomerServiceEire@mirashowers.com ● Products purchased ex-showroom display. Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifi cations without notice. 14648 1365393-W2-A © Kohler Mira Limited, January 2019...