Section 7
Technical data
7.3
7.4
38
Environmental conditions and tests
Table 7:
Environmental conditions
Description
Service temperature range
Transport and storage temperature range
Table 8:
Environmental tests
Description
Dry heat test
Dry cold test
Electromagnetic compatibility tests
Table 9:
Power Supply module
Description
1 MHz burst disturbance test, class IV
•
Common mode
•
Differential mode
Fast transient disturbance tests, class IV
Surge immunity test
Electromagnetic emission tests
•
Conducted, RF-emission (Mains term.)
•
Radiated RF-emission
Value
-10...+55 °C / 14...131 °F (continuous)
-20...+70 °C / -10...158 °F according to IEC
60068-2-48
Value
According to IEC 60068-2-2
Test values:
•
96 h at +65 °C
•
Start-up at +55 °C
According to IEC 60068-2-1
Test values:
•
96 h at -40 °C
•
Start-up at -40 °C
Value
According to IEC 61000-4-4
4 kV
2 kV
According to IEC 61000-4-4
4 kV
According to IEC 61000-4-5
4 kV, line-to-earth
2 kV, line-to-line
According to EN 55011
EN 55011 (0.15...30 MHz)
IEC 61000-4-3 (80 MHz...1 GHz, 10 V/m)
Installation and commissioning manual
1MRS755551 B
WGA631