Thank you very much for purchasing Panasonic products. Read this Instruction Man-
ual carefully and thoroughly for the correct and optimum use of this product. Kindly
keep this manual in a convenient place for quick reference.
● Never use this product as a device for personnel protection.
● When using devices for personnel protection, use products that meet the laws
and standards for personnel protection that apply in each region or country, such
as OSHA, ANSI and IEC.
This document provides a brief summary of mounting and other related information.
For detailed information, refer "our web site (http://panasonic.net/id/pidsx/global)".
1
STANDARDS AND REGULATIONS
● This product conforms to the standards and regulations below.
<European Directives>
EMC Directive
● Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
2
CONTENTS OF PACKAGE
Sensor head
Mounting nut
Sensor head fastening wrench
Rubber bellows (HG-S□R only)
Instruction Manual (English / Japanese, Chinese / Korean)
3

DESCRIPTION OF PARTS

Sensor head connection cable connector
Operation indicator (Orenge / Green)
Mounting nut
Rubber bellows
Probe
INSTRUCTION MANUAL
HG-S□
MJE-HGS1010 No.0052-70V
WARNING
4
MOUNTING
● When tightening the mounting nut, take care not to damage the rubber bellows.
● If the rubber bellows is deformed, a load will occur when the spindle operates
and damage may result.
1. Open a hole in the housing in which the sen-
sor head will be mounted.
2. Insert the sensor head into the hole you
opened in the housing, and fasten lightly
with the provided mounting nut.
3. Fasten the sensor head.
When fastening the sensor head, tighten the
mounting nut with a wrench while holding the
sensor head in place with the sensor head
fastening wrench as shown at right.
Tighten to a torque of 12.5N·m or less.
1 pc.
1 pc.
1 pc.
1 pc.
4. Make sure that the rubber bellows has not
2 pcs.
become deformed as shown at right.
If the rubber bellows is deformed, restore the
normal shape by rotating the bellows or oth-
erwise.
Connecting the sensor head connection cable
When disconnecting, always make sure that the fastening ring has been complete-
ly loosened before pulling out the cable.
Risk of damage if you pull the cable with excessive force (15N or more) with the
fastening ring tightened.
How to connect
1. Insert the sensor head connection
cable into the connector for the
sensor head connection cable on
the sensor head.
2. Turn the fastening ring on the sen-
sor head connector in the direction
shown to fasten the ring.
How to remove
1. Turn the fastening ring on the sen-
sor head connector in the direction
shown to loosen the ring.
2. Grasp the connector and pull up to
remove the cable.
Mounting hole
6.5 to 12.5mm
ø8H7
+0.015
0
Mounting nut
(Accessory)
Sensor head
fastening wrench
(Accessory)
Wrench
1. Insert
2. Tighten
1. Loosen
mm
2. Pull out

Advertisement

loading

Summary of Contents for Panasonic HG-S Series

  • Page 1: Description Of Parts

    1. Open a hole in the housing in which the sen- MJE-HGS1010 No.0052-70V sor head will be mounted. Thank you very much for purchasing Panasonic products. Read this Instruction Man- ual carefully and thoroughly for the correct and optimum use of this product. Kindly Mounting hole 6.5 to 12.5mm...
  • Page 2: Specifications

    Phone: +81-568-33-7861 FAX: +81-568-33-8591 Turn For sales network, please visit our website. 3. After attaching the probe, wipe the spindle with absolute alcohol to remove any dirt. PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2015...

This manual is also suitable for:

Hg-s1010Hg-s1110Hg-s1010rHg-s1110r