Page 2
U-SYS IAD208E(M) Integrated Access Device User Manual Issue Date 2007-7-28 Part Number 31016569 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters. Huawei Technologies Co., Ltd.
Page 4
Chapter 4 Configuring Data presents how to configure various data needed for providing various services. Chapter 5 Advanced Configuration introduces various advanced configurations related to IAD208E(M) when cooperating with other devices. Huawei Technologies Proprietary...
The manual uses the following conventions: I. General conventions Convention Description Arial Normal paragraphs are in Arial. Warnings, Cautions, Notes and Tips are in Arial Narrow Arial Narrow. Boldface Headings are in Boldface. Terminal Display is in Courier New. Courier New Huawei Technologies Proprietary...
< > example, click the <OK> button. Window names, menu items, data table and field names are inside square brackets. For example, pop up the [New User] window. Multi-level menus are separated by forward slashes. For example, [File/Create/Folder]. Huawei Technologies Proprietary...
Page 7
Press and hold the left button and drag it to Drag a certain position. VI. Symbols Eye-catching symbols are also used in this manual to highlight the points worthy of special attention during the operation. They are defined as follows: Huawei Technologies Proprietary...
Page 8
Note, Comment, Tip, Knowhow, Thought: Means a complementary description. Environmental Protection This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed. Huawei Technologies Proprietary...
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents Table of Contents Chapter 1 System Overview ............1-1 1.1 Introduction to Product ............1-1 1.2 Service Functions...............1-3 1.3 System Structure..............1-3 1.3.1 Hardware Structure ..........1-3 1.3.2 Software Structure...........1-5 Chapter 2 Installing Hardware............2-1 2.1 Installation Requirements ..........2-1...
Page 10
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents 3.1.2 Setting up the Environment for Loading through Telnet ..................3-8 3.2 Configuring (T)FTP Server..........3-11 3.2.1 Configuring TFTP Server ........3-11 3.2.2 Configuring FTP Server.........3-14 3.3 Loading Software .............3-19 3.3.1 BIOS Mode ............3-20 3.3.2 Command Line Loading Mode ......3-30...
Page 11
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents 4.4.2 Collecting Data ............4-48 4.4.3 Configuring Basic Information of IAD208E(M) ..4-49 4.4.4 Configuring MG Attribute Data ......4-51 4.4.5 Configuring Voice User Data.........4-53 4.4.6 Saving Configuration Data ........4-56 Chapter 5 Advanced Configuration ..........5-1 5.1 Configuring Common Attributes of Access User ....5-1...
Page 12
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents 6.2.1 Starting/Terminating Access Service ....6-13 6.2.2 Resetting Access User Port ........6-15 6.2.3 Showing Port Status ..........6-15 6.2.4 Showing Access User Data........6-16 6.2.5 Sending On-hook Signals to Console ....6-17 6.3 Operator Management .............6-18 6.3.1 Adding/Deleting Operator ........6-19...
Page 13
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents 6.5.1 Setting the Level of Call Logs........6-47 6.5.2 Querying All the Call Logs ........6-48 6.5.3 Querying the Level of Call Logs ......6-48 6.5.4 Querying the Quantity of Call Logs .......6-49 6.5.5 Querying the Call Logs of a Specific Period..6-49...
Page 14
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents 7.2 FAQs ..................7-9 7.2.1 IAD Port ID Error Leads to Call Failure....7-9 7.2.2 Echo Occurs in PSTN Calls........7-12 7.2.3 Call Fails After Telephone Ringing......7-13 7.2.4 Monolog..............7-14 7.2.5 Voice Quality Deterioration........7-16 7.2.6 IAD Echo ...............7-17...
Page 15
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents Table of Contents Chapter 1 System Overview ............1-1 1.1 Introduction to Product ............1-1 1.2 Service Functions...............1-4 1.3 System Structure..............1-4 1.3.1 Hardware Structure ..........1-4 1.3.2 Software Structure...........1-6 Huawei Technologies Proprietary...
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 1 System Overview Chapter 1 System Overview This chapter introduces the function and structure of IAD208E(M) Integrated Access Device (hereinafter referred to as IAD208E(M)). 1.1 Introduction to Product Huawei’s IAD208E(M) is an access media gateway (AMG) based on the technologies of voice over IP (VoIP) and fax over IP (FoIP).
Page 17
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 1 System Overview Figure 1-1 Appearance of the IAD208E(M) The IAD208E(M) is located in the user access level of NGN, as shown in Figure 1-2. Huawei Technologies Proprietary...
Page 18
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 1 System Overview 3rd party server iOSS SoftSwitch SoftSwitch 多 媒 体 终 端 IP Network Ephone PSTN IAD208 phone phone iOSS: integrated operation support system AAA: authentication, authorization and accounting SCP: service control point...
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 1 System Overview 1.2 Service Functions The IAD208E(M) can provide abundant services: Access POTS users to IP network. Access Ethernet users into IP packet network. Support IP semi-permanent connection (SPC) and internal SPC.
Page 20
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 1 System Overview Table 1-1 Table of IAD208E(M) indicators Indicator Color Name Meaning When local power supply is connected, it is on. If there is Power no power supply, it is off.
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 1 System Overview (1) Local power supply interface (2) Upstream interface (3)–(10) 8 channels of unified (11) Local maintenance serial interfaces for data and voice services port Figure 1-3 External interface of the IAD208E(M) 1.3.2 Software Structure...
Page 22
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 1 System Overview Bottom layer drive module The relations among the modules are shown in Figure 1-4. Management, maintenance and operation module SPC processing module TDM/DSP Service access module VoIP service processing module TDM/DSP...
Page 23
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 1 System Overview Module Function It implements the selection, summary and Service access report of analog user and digital user module information, and transmits the messages issued by the service module. It establishes and maintains the SPCs...
Page 24
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents Table of Contents Chapter 2 Installing Hardware............2-1 2.1 Installation Requirements...........2-1 2.1.1 Attentions in Installation ..........2-1 2.1.2 Requirements for Installation Environment .....2-2 2.1.3 Requirements for Electromagnetic Environment..2-2 2.1.4 Tools and Meters.............2-3 2.2 Installing Hardware ............2-4...
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 2 Installing Hardware Chapter 2 Installing Hardware IAD208E(M) consists of the hardware system and the software system. Before running the equipment, you need to install the hardware and load the software. 2.1 Installation Requirements 2.1.1 Attentions in Installation...
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 2 Installing Hardware Item Description Never open the shell when the device is working. Do not open the shell, even if it is powered off, unless absolutely necessary. Before cleaning IAD208E(M), pull out the power plug of the device.
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 2 Installing Hardware Table 2-2 Measures for preventing electromagnetic interference Item Description AC power receptacles should be monophase three-wire receptacles with protection grounding (PE). So that the filtration circuit on the equipment can effectively filter the interference from electricity power supply.
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 2 Installing Hardware Table 2-4 Steps for installing hardware Steps Operation Fixing IAD208E(M) box onto the specified location Connecting serial port cable (optional) Connecting upstream cable Connecting user side cable Connecting power cable 2.2.1 Putting IAD208E(M) on Desktop...
Page 30
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 2 Installing Hardware Figure 2-1 Serial port of IAD208E(M) The serial port is on the right part of the device’s rear panel. It is labeled as CONSOLE. Features of serial port are: transmission rate of 9600 bit/s, without parity check, 8 data bits, one stop bit, without traffic control.
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 2 Installing Hardware The steps for connecting the serial port cable are as follows: Connect female end of the serial port cable to the DB-9 male connector on the PC or terminal that will configure IAD208E(M).
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 2 Installing Hardware strip to the gap on the interface and insert the RJ-45 connector. If a “click” is heard, the connector is well plugged. Insert the other end of the network cable into the interface on the network adapter of the PC.
Page 33
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 2 Installing Hardware Insert the output end of AC-DC power cable into the power socket on the back panel of IAD208E(M), and the other end into the external AC power socket. Check whether the power indicator (PWR) on the front panel is normal.
User Manual U-SYS IAD208E(M) Integrated Access Device Table of Contents Table of Contents Chapter 3 Updating Software ............3-1 3.1 Setting Up Configuration Environment for Loading ...3-1 3.1.1 Setting up Configuration Environment for Loading through Local Serial Port ..........3-1 3.1.2 Setting up the Environment for Loading through Telnet ..................3-8...
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 3 Updating Software Chapter 3 Updating Software For IAD208E(M), loading software means to write the programs and data files that are needed by the normal running of equipment into Flash memory, so as to ensure the system can be upgraded and run normally.
Page 36
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 3 Updating Software already be connected when you are installing hardware. Refer to Chapter 2. Console port of IAD Serial port cable Maintenance terminal Serial port of PC Figure 3-1 Connection for configuring through local serial port...
Page 37
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 3 Updating Software Figure 3-2 Set up a HyperTerminal connection In the “Connect using” text box, select the actually used serial port number, like “Com1”, as shown in Figure 3-3. Then click <OK>.
Page 38
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 3 Updating Software Figure 3-3 Select the serial port number Set the parameters of serial port: baud rate as 9600 bit/s (it must be consistent with that configured on IAD208E(M) serial port, and the default value is 9600 bit/s), data bit as 8, 1 stop bit, without parity check and flow control.
Page 39
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 3 Updating Software Figure 3-4 Set the properties for COM 1 Select the [File/Properties/Settings] menu in the HyperTerminal window, and set the Telnet terminal and emulation types as "ANSI" and "Auto Detect". Refer to Figure 3-5.
Page 40
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 3 Updating Software Figure 3-5 Set the properties of IAD208E(M) Click the <ASCII Setup> button, set the "Line delay" and "Character delay" of the "ASCII sending" as 50ms, as shown in Figure 3-6.
Page 41
User Manual U-SYS IAD208E(M) Integrated Access Device Chapter 3 Updating Software Figure 3-6 Set ASCII Huawei Technologies Proprietary...