In case of gear units with addon oilsupply
system, before starting the unit up the
pressure
connected so as to be ready for operation.
Depending on the order specification and application, the
flanged pump may be replaced with a motor pump.
When operating and servicing the components of the oilsupply system, observe the operating
instructions of the components.
For technical data, refer to the data sheet and/or the list of equipment.
5.6
Shaft bearings
All shafts are mounted in rolling bearings.
5.7
Shaft seals
Depending on requirements, radial shaftsealing rings or Taconite seals are fitted at the shaft exits to
prevent oil from leaking from the housing and dirt from entering it.
5.7.1
Radial shaftsealing rings
Radial shaftsealing rings are the standard type of seal. They are fitted with an additional dust lip to protect
the actual sealing lip from external contamination.
For special mounting positions the radial shaftsealing ring is used with a grease filling
in combination with a ring.
Where large quantities of dust occur as specified by the requirements in
Directive 94/9/EC, use is provided only in combination with the Taconite seal
(see item 5.7.2).
Fig. 16: Radial shaftsealing ring
monitor
must
always
BA 5033 EN 03/2011
28 / 96
0.5 bar
be
To be
connected as
opener or
closer, as
required.