Configure Speed Monitor; Password Protection - Pilz PNOZ s30 Operating Manual

Safety relays
Hide thumbs Also See for PNOZ s30:
Table of Contents

Advertisement

Commissioning
6.2.3

Configure Speed Monitor

The settings are made via the rotary knob, as follows:
Press the knob
}
Confirm selection/setting
}
Switch to menu
Rotate knob
}
Select menu level
}
Set the parameter/numeric value
The speed with which you turn the knob affects the sequence of the menu and numeric val-
ues:
}
Slowly: Units
}
Quickly: Tens
}
Very quickly:
6.2.4

Password protection

The configuration is protected through passwords. There is a master password and a cus-
tomer password.
Factory setting for both passwords: 0000
The password levels contain different authorisations:
}
Master password
Display: All settings
Edit: All settings
Operating Manual PNOZ s30
1001715-EN-13
Setting the numeric value: Hundreds
When switching the menu level: Jump to ESCAPE
CAUTION!
Please note that all parameters are set to their default values on delivery.
Please check all the safety-related parameters at least, and enter the values
that correspond to your application.
Information
If no value is set or amended within 30 s of a menu action, the display re-
verts to the default display. The current setting remains unchanged.
If the master password has been entered, this time increases to 5 minutes.
40

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PNOZ s30 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF