Guide rail with integrated closing sequence control and free-swing door closer on the moving leaf (25 pages)
Summary of Contents for GEZE TSA 160 NT
Page 1
TSA 160 NT EN Installation and service instructions TSA 160 NT F TSA 160 NT-IS TSA 160 NT F-IS TSA 160 NT Z TSA 160 NT Invers TSA 160 NT Z Invers 133043-06...
General installation information ................................14 Fitting dimensions ......................................16 Installing the drive ......................................24 Extension TSA 160 NT F and TSA 160 NT F -IS ............................. 26 Extension of the integrated closing sequence control TSA 160 NT -IS, TSA 160 NT F -IS, TSA 160 NT Z -IS, TSA 160 NT IS/TS ......................................26 Installing TSA 160 NT Invers ..................................
TSA 160 NT and variants Symbols and illustrations Warning notices In these instructions, warnings are used to warn against material damage and injuries. Always read and observe these warnings. Observe all measures marked with the warning symbol and warning word.
Safety notices 1. 1 Intended use The TSA 160 NT swing door drives are designed for the automatic opening and closing of single action swing doors. The above mentioned door drive is suitable: à solely for use in dry rooms à...
TSA 160 NT and variants Tools and aids Safety-conscious working à Secure workplace against unauthorised entry. à Watch the swivelling range of long system parts. à Never carry out work with a high safety risk (e.g. installing the drive, cover or door leaf) while alone.
Transportation and storage à The TSA 160 NT door drive is not built for hard knocks or for falling from a height. Do not throw, do not drop. à Storage temperatures under -30 °C and above +60 °C can result in damage to the device.
4 sec. min. 4 sec. Maximum door opening angle: 115° see section 6.2.5 * Guideline values - the TSA 160 NT is an electro-hydraulic door drive. The maximum opening or closing times set longer by powerful closing of the valves.
Page 8
Product description TSA 160 NT and variants Maximum range of use TSA 160 NT EN3–6 1000 1100 1200 1300 1400 Türbreite/Door width [mm] Link arm Roller guide rail Mechanical data à Dimensions (H x D x L): 100 mm × 120 mm × 690 mm à...
TSA 160 NT and variants Product description Basic structure 5.2. 1 Drive TSA 160 NT EN 3–6 Side plate Opening speed (ÖD) Base plate (for Invers drives: closing speed (SG)) Control unit Driveshaft Hydraulic cylinder Identification plate Closing torque adjustment Latching (SE)
Page 10
Product description TSA 160 NT and variants 5.2.2 Link arm Standard link arm: for reveal depth LT *: à 0-100 mm à 100-200 mm à 200-300 mm à 300-400 mm permissible reveal in combination with fire protection doors max. 300 mm...
Page 11
Reset switch Accessories for TSA 160 NT F “Ü” symbol The TSA 160 NT F is designated for use on fire and smoke protection doors. Permit- ted type of installation: DIN 18263-4 à Transom installation opposite hinge side with link arm (1-leaf / 2-leaf) in the...
TSA 160 NT and variants Types of installation 5.3. 1 Single leaf The TSA 160 NT allows the following types of installation, each for DIN left and DIN right doors: Hinge side Opposite hinge side Roller guide rail Link arm TSA 160 NT Z / TSA 160 NT Invers...
Page 13
TSA 160 NT and variants Product description 5.3.3 TSA 160 NT Invers types of installation TSA 160 NT Invers Factory setting DIN right door Conversion to DIN left door necessary DIN right door pulling DIN left door pulling Hinge side...
Installation TSA 160 NT and variants Installation 6. 1 General installation information After completing installation, check the settings and functionality of the drive. Observe all the instructions. Incorrect installation can lead to serious injuries and damage to the drive. Observe the specified ambient temperature range at the installation location of the drive (see section 5.1).
Page 15
TSA 160 NT and variants Installation TSA 160 NT / TSA 160 NT Z Invers DIN right door DIN left 3 4 5 Procedure Unscrew the limit switch (2), unscrew the limit switch bar (4). Dismantle the blue (5) and yellow (6) cam plates. Bend the black cover plate (1) slightly to one side to do so.
Opening angle depending on the type of installation A stop buffer is imperative if a TSA 160 NT Invers / TSA 160 NT Z Invers is used. A stop buffer is recommended if a TSA 160 NT / TSA 160 NT Z is used.
Page 17
TSA 160 NT and variants Installation Attachment with mounting plate 487.5 162.5 Dimensional reference = middle of hinge GEZE logo facing the hinge side Ø 20, concealed cable routing Fixing hole Ø 8 Fixing hole Ø 6 Fixing hole Ø 5...
Page 18
Installation TSA 160 NT and variants 6.2.2 Transom installation hinge side with roller guide rail single leaf Direct attachment Dimensional reference = middle of hinge Ø 20, concealed cable routing Attachment with mounting plate 487.5 162.5 Dimensional reference = middle of hinge GEZE logo facing the hinge side Ø...
Page 19
TSA 160 NT and variants Installation With 24 mm spindle extension Without spindle extension 6.2.3 Transom installation opposite hinge side with link arm double leaf Direct attachment Dimensional reference = middle of hinge Active leaf Ø 20, concealed cable routing...
Page 20
Installation TSA 160 NT and variants Fixing with mounting plates 487.5 487.5 162.5 162.5 Dimensional reference = middle of hinge Passive leaf Ø 20, concealed cable routing Active leaf GEZE logo facing the hinge side Intermediate mounting plate Fixing with continuous mounting plate B /2 487.5...
Page 21
TSA 160 NT and variants Installation With 24 mm spindle extension Without spindle extension 6.2.4 Transom installation hinge side with roller guide rail double leaf Direct attachment Dimensional reference = middle of hinge Passive leaf Ø 20, concealed cable routing...
Page 22
Installation TSA 160 NT and variants Fixing with mounting plates 487.5 487.5 162.5 162.5 Dimensional reference = middle of hinge Passive leaf Ø 20, concealed cable routing Active leaf GEZE logo facing the hinge side Fixing with continuous mounting plate 487.5...
Page 23
TSA 160 NT and variants Installation With 24 mm spindle extension Without spindle extension 6.2.5 Installation of the guide rail with reveal depths Reveal depth L (from-to) Dimension X for guide rail with Door width (min.) Opening angle TSA 160 NT Z >0–25 mm...
Installation TSA 160 NT and variants Fasteners (optional) Steel/aluminium doors Wooden doors Attachment of the extension kit 4 cylinder head screws M5 and riveting nuts 6 wood screws with button without mounting plate (direct head Ø5 attachment) Attachment of the extension kit with mounting plate à...
Page 25
Tighten the 2 screws (6). 15° 6.3.2 Install the drive on the hinge side (pulling; roller guide rail) TSA 160 NT / TSA 160 NT Z Invers Press the spacer bush (2) into the lever bush. Slide the roller lever (4) onto the drive shaft (1) at an angle of 15°...
Extension TSA 160 NT F and TSA 160 NT F -IS The TSA 160 NT F and TSA 160 NT F-IS automatic systems are automatic swing door drives with an integrated hold-open device for fire protection doors, smoke protection doors and doors that should be self-closing (fire barriers).
Page 27
TSA 160 NT and variants Installation Insert the wire rope (1) in the IS block (active leaf) and fasten it with the clamping screw (3). Installation on the passive leaf drive Push the cam plate (6) onto the lever (4) of the fixed leaf drive and pre-assemble using the clamping screws (5) as shown in the drawing.
Page 28
Installation TSA 160 NT and variants Pull the wire rope (1) tight and clamp tight with the clamping screw (10). The trip rocker (8) must continue to lie against the cam plate (6). Installation on the active leaf drive Adjust the adjusting nut (15) so that the marking arrow (11) exactly covers the marking notch (13) at the IS valve (12).
TSA 160 NT and variants Installation Installing TSA 160 NT Invers 6.6. 1 Transom installation opposite hinge side with link arm Drill threaded holes on the door frame or mounting plate. Fix the door drive to the door frame or moun- ting plate.
Page 30
TSA 160 NT and variants 6.6.2 Transom installation hinge side with roller guide rail WARNING! Risk of injury when the door is let go (TSA 160 NT Invers). Fix the door in place if necessary. Drill threaded holes on the door frame or mounting plate.
TSA 160 NT and variants Electrical installation and device settings Electrical installation and device settings For electrical installation and device setting: See wiring diagram 7. 1 Mains connection DANGER! Risk of fatal injury due to electric shock! The electrical system (230 V) may only be connected by a qualified electrician.
Page 32
Electrical installation and device settings TSA 160 NT and variants 7.2.2 TSA 160 NT Invers limit stop Factory setting: 0° door opening angle. Hold the door in the closed position. Set the blue cam plate (1) so that the limit switch is operated in the closed position of the door.
Page 33
TSA 160 NT and variants Electrical installation and device settings 7.2.4 Closing torque for TSA 160 NT F and standard values for other drives The door closer power size (closing force of the closer) depends on the door width. The door leaf widths and door closer power sizes specified in EN 1154 are binding for the TSA 160NT F.
Page 34
Electrical installation and device settings TSA 160 NT and variants 7.2.5 Speed adjustment For 2-leaf systems the integrated closing sequence control ensures that the active leaf begins its closing process approx. 1.5 s after the passive leaf. The speeds have to be set so that the passive leaf is closed first.
à Within electrical commissioning, the door closing torque of the power storage device must be set in accordance with intended use of the door system as a (fire protection/personal protection door), see chapter 7.2.4. Enter the correct marking on the identification plate. Position of the plates on the TSA 160 NT "Ü" symbol Identification plate...
Electrical installation and device settings TSA 160 NT and variants Special requirements made on the drive/functions/installations (sixth character) Three out of five application classes are relevant for the swing door drive: No special requirements On escape routes without turn-tilt fittings For self-closing fire protection doors without turn-tilt fittings Note: Only one class may be specified.
TSA 160 NT and variants Final check Final check The mandatory installation, maintenance and repair work must be performed by properly trained personnel authorised by GEZE. Written proof of the test is required. Safety analysis (risk analysis) In accordance with Machinery Directive 2006/42/EC and DIN 18650, before commissioning the door, a safety ana- lysis (risk assessment) must be performed and the door system must be labelled in accordance with CE Marking Directive 98/68/EEC.
Let the motor cool down. Maintenance work on the TSA 160 NT The TSA 160 NT is maintenance-free to a great extent and no extensive work has to be carried out with the ex- ception of that specified below: Check the roller lever or the link arm for damage, replace if necessary.
TSA 160 NT and variants Service and maintenance Electrical faults Fault messages are stored and can be retrieved using the display programme switch, the service terminal ST220 or GEZEconnects. If a fault is currently active, it is shown every 10 seconds on the display programme switch or the service terminal ST220.
Need help?
Do you have a question about the TSA 160 NT and is the answer not in the manual?
Questions and answers