ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com GT-1000 SERIES MULTIFUNCTIONAL GAS AND DUST DETECTOR USER MANUAL 深 圳 市 科 尔 诺 进 出 口 贸 易 有 限 公 司 ShenZhen Korno Import&Export Co.,Ltd...
Page 2
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com WARNING Read and understand this instruction manual before operating instrument. Improper use of the gas monitor could result in bodily harm or death. Periodic calibration and maintenance of the gas monitor is essential for proper operation and correct readings.Please calibrate and maintain this instrument...
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com Notice Button description ① There are seven buttons beneath the display screen: Up,Down,Back,Ok,run/stop, Power,Print Three operation interfaces:Detector interface,menu,parameter setting. The following form is description for the seven buttons. The table below illustrates the function of seven buttons.
Page 5
1. All operations are operate by a short press of the button unless it is special noticed 2. GT-1000 series multifunctional gas and dust detector could be work normally only in condition of the pump was switched on Gas Detector Processing Operation under Out-range Status ②...
Page 6
Also the calibration need to be operate under the guidance of the professional. All GT-1000 series products we provide 12-Mounths warranty for the detector and 3-Mounth warranty for the accessories. Beside , we have free calibration once a year during the entire products service life.
1.Product Brief Introduction GT-1000 series multifunctional gas detector are portable gas and dust detector which can be configure flexibly up to 5 gas sensors or 3 gas sensors plus 1 dust sensor.With import gas sensor and most advance nanometer semiconductor technology GT-1000 series multifunctional gas detector can detect corresponding gas and dust concentration at the same time rapidly and precisely,we maintain a leading position in domestic level and our products are famous of high stability and repeatability .User can custom setting...
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 2.Key Features With the most advance nanometer semiconductor technology ,ultra low power 32bit microprocessor,24bit ADC data acquisition chip,outstanding accuracy. 3.5 inches IPS technical grade display with a pixel up to 320*480,display technical indicators and gas concentration value perfectly.
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 3.Technical Parameters Product type: Multifunctional gas detector(Customize according to user need) Detection Range: Please refer to sensor list at end of this manual Display: Please refer to sensor list at end of this manual Scalable gas...
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 5.Operation Instruction 5.1Button Description There are seven buttons beneath the display screen: Up,Down,Back,Ok,Run/stop,Power,Print Three operation interface:Detector interface、Menu、Parameter setting. The following form is description of the seven buttons. Detector interface Menu parameter setting Save instant data(press and hold for 5 seconds)
Print Print instant gas concentration data Invalid Invalid CAUTION: GT-1000 series multifunctional gas detector will perform normally Only in condition of the pump was switched on 5.2Power On Long press power button for five seconds until you hear a beep the “DI”...
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 5.3Power Off In normal detection mode long press power button for five seconds until the “DI” sound ,display shows shutting down as it show in figure 5,device will be shut off within 1 minute .
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com concentration figure. 6.2 Function Menu Instruction Long press”OK” button for 5 seconds to enter function menu as shown in figure 10. Nine sub-menus are including in function menu:Basic setting、History Log、RealTime Curve、 Zero calibration、Target calibration、Alarm setting、Measure Mode、Storage setting、...
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 4. Humi Correction:In this menu user were allow to modify the humidity parameter manually as shown in figure 15. 5. Gravity Calibrate: In this The gravity sensor can be re-calibrated as shown in figure 16.
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 3.History Log Export:Press “OK” and follow the procedure as it shown in figure 26 to export the history data. 4.Clear CH History Log:Press “OK” to enter this sub-menu,in this menu users can view all the sensors and corresponding data quantity,press “OK”...
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 6.2.4 Zero Calibration If zero drift of the sensor is over range, user can proceed zero calibration ,the gas concentration are defaulted set to zero after zero calibration as shown in figures 30. Special Note: 1.Zero calibration must be proceed in fresh air or high-purity inert gas(for example 99.999%VOL N2 etc) 2.Do not operate zero calibration for those gases which already exist in the air,such as oxygen,carbodioxide,nitrogen.
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com operate under conditions of certain standard concentration gas, Pressure reduction valve ,Flow meter, Calibration cover and make sure all instruments are well connected, otherwise this function is forbidden. Procedures: Connect all instruments as shown in figure 33,enter target gas calibration interface,release standard gas slowly and control gas flow within 600ml/min,observe the real-time concentration value(concentration value should be increasing),wait until real-time concentration value rise to the peak reading and stay still, user can chose a un-calibrate option to operate(√...
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 6.2.7 Measure Mode User can choose two measure mode:real time measure and fixed time measure as shown in figure 36.When detector is preset as “real-time measure”mode, it provides continuous monitoring and will shows real-time concentration of each channel in the display.And you can select the duration of each fixed time detection, the detect cycle times and the interval between the two fixed time measure as shown in figure 37.
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 6.2.10 Time Setting Time setting menu allow user to set date and time,this time is related to the time of the concentration values are being recorded as it shown in figure 42. 6.2.11 Factory Setting If user proceeded an wrong operation by accidentally or need to reset all parameters to factory setting,you can reset all parameter to factory setting as it shown in figure 43.
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 7. Common Faults and Exclusions Problem Concentration value is not stably when detector place in air, reading is unstable Possible reasons: Electrochemical sensor might interfered with unrelated colorless and odorless gas Solutions: Place detector at pure gas environment to see whether the concentration value decreasing or not, if it is that the...
Page 23
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com Problem: Concentration value is unstable when start detecting. Possible reasons: Normally dude to gas oxygen content is too low or changing of gas concentration value. Solutions: Increase gas oxygen content value and make sure the gas flow speed is stable.
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com 8.Concentration Datalog Output Instruction GT -1000 series gas detector allow user output history datalog via the charge port,there are several steps to output datalog. 1) Install concentration datalog output software in host computer 2) Boot up the detector and wait for 30s to preheat the instrument and connect to the computer...
Page 25
ShenZhen Korno Import&Export Co.,Ltd http://szkorno.en.made-in-china.com Notice Please read User Manual carefully before use the detector. It is strictly forbidden user to disassemble the detector or replacement parts. Installation, adjustment, calibration and parameters setting must be progress by professionals.