Beko BCT9031G User Manual page 10

Table of Contents

Advertisement

without a transformer. The Manufacturer shall not be
liable for any damages that will arise due to using the
product without a grounding installation in accordance
with the local regulations.
m~~eN;~~~ct
must be connected to the
mains supply only by an authorised and
qualified person. The product's warranty
period starts from date of sale or date of
delivery. Manufacturer shall not be held
responsible for damages arising from
procedures carried out by unauthorised
persons.
he power cable must not be clamped, bent or
I--~1rapped or come into contact with hot parts of
the product.
A damaged power cable must be replaced by
a qualified electrician. Otherwise, there is risk
of electric shock, short circuit or fire!
Connection must comply with national
regulations.
The mains supply data must correspond to the
data specified on the type label of the product.
Type label is at the rear housing of the product.
Power cable of your product must comply with
the values in "Technical specifications" table.
ANGER:
efore starting any work on the electrical
nstallation, disconnect the product from the
mains supply.
There is the risk of electric shock!
Connecting the power cable
Dl
hile performing the wiring, you must comply
th the national/local electrical regulations
nd must use the appropriate socket
outleVline and plug for oven. In case the
product's power limits are out of current
carrying capability of plug and socket
outleVline, the product must be connected
through fixed electrical installation directly
without using plug and socket outleVline.
1. If it is not possible to disconnect all poles in the
supply power, a disconnection unit with at least 3
mm contact clearance (fuses, line safety switches,
contactors) must be connected and all the poles
of this disconnection unit must be adjacent to (not
above) the product in accordance with IEE
directives. Failure to obey this instruction may
10/EN
cause operational problems and invalidate the
product warranty.
Additional protection by a residual current circuit
breaker is recommended.
If a ca,ble is supplied ""'ith the product:
1 N AC 220-240V
NI
2.
For single-phase connection,
connect the wires
» or
as identified below:
Brown/Black cable
=
L (Phase)
Blue/Grey cable
=
N (Neutral)
Green/yellow cable
=
(E)
@
(Ground)
Grey/Black cable
=
L (Phase)
Blue/Brown cable
=
N (Neutral)
Green/yellow cable
=
(E)
@
(Ground)
Installing the product
If the oven is below:
A
min.15 mm
B
min.2 mm
C
20 mm
If the board is below:
It is required to leave a ventilation opening of minimum
180 cm
2
at the rear section of the cabinetry as
illustrated in the following figure.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents