Before programming the thermostat press the + & – AND ∧ ∧ ∧ ∧ ∧ and ∨ ∨ ∨ ∨ ∨ buttons
simultaneously to reset the unit (Fig.1)
Setting the Clock and Day
Press PROG (Fig.2) to begin programming
Use + or – buttons (Fig.3) to adjust the TIME (Fig.4)
Press PROG again (Fig.2)
Use + or – buttons (Fig.3) until correct DAY is shown (Fig.5)
(1 = Monday, 2 = Tuesday, etc)
Accepting the Factory Pre-settings
The TP5000 has pre-set times already programmed in, which often suit most
people (see Table below).
To accept these settings close the front cover and after 2 minutes the pre-
settings will automatically be accepted.
Mon-Fri
Event
Time
Temp°C
1
06.30
2
08.30
3
11.30
4
13.30
5
16.30
6
22.30
To adjust the factory pre-settings & set your own time and
temperature programmes
For Days 1-5 (weekdays)
a) Press PROG (Fig.2) 3 times to show the 1
(Event 1 Days 1,2,3,4,5) (Fig.6)
b) Use + or – buttons (Fig.3) to adjust the TIME (press and hold to change in
10 min increments)
c) Use ∧ ∧ ∧ ∧ ∧ or ∨ ∨ ∨ ∨ ∨ buttons (Fig.7) to adjust the TEMPERATURE
d) Press PROG (Fig.2) to move to next preset time & temp (Event 2) (Fig.8)
e) Repeat steps b, c & d for programming Events 3, 4 5 & 6
For Days 6-7 (weekends)
Press PROG (Fig.2) to show 1
G
Days 6-7) (Fig.9)
Repeat steps b, c and d above to programme time and temperature events
G
for the weekend
Returning to RUN mode
Press PROG (Fig.2) – the colon in the LCD display will start to flash (Fig.10)
TP5000
User Instructions
Sat-Sun
Event
20
1
15
2
20
3
15
4
21
5
15
6
st
pre-set time and temperature
st
pre-set time and temperature (Event 1
Time
Temp°C
07.00
20
16.00
21
23.00
15
00.00
15
01.00
15
01.59
15
Fig.1
Fig.2
Fig.3
i2 00
Fig.4
Fig.5
1
1
6 30
Fig.6
1 2 3 4 5
Fig.7
2
8 30
Fig.8
1 2 3 4 5
Fig.9
1
7 00
Fig.10
i2 24
1
20
15
20
6 7
20

Advertisement

loading
Need help?

Need help?

Do you have a question about the TP5000 and is the answer not in the manual?

Questions and answers

joe considine
March 14, 2025

the tp5000 thermostat control is blank I have changed the batteries and pressed the reset nothing seems to work can you advise

1 comments:
Mr. Anderson
March 14, 2025

The Danfoss TP5000 thermostat control may remain blank after changing the batteries and resetting due to the following reasons:

1. Poor Battery Contact: The metallic strips in the battery chamber may have been pushed back too far, preventing proper contact with the batteries. Slightly adjusting these strips with a non-metallic object like a cocktail stick can help ensure a snug fit.

2. Battery Replacement Delay: If new batteries are not inserted within one minute of removing the old ones, the unit may lose its programming and require resetting.

3. Reset Required: After installing new batteries, pressing and releasing the reset button is necessary to start the unit.

If these steps do not resolve the issue, further troubleshooting may be needed.

This answer is automatically generated

Summary of Contents for Danfoss TP5000

  • Page 1 (1 = Monday, 2 = Tuesday, etc) Fig.2 Accepting the Factory Pre-settings The TP5000 has pre-set times already programmed in, which often suit most people (see Table below). Fig.3 To accept these settings close the front cover and after 2 minutes the pre- settings will automatically be accepted.
  • Page 2 Selection of time Fig.11 Temporary User Overrides or actual room temperature The TP5000 has several useful overrides which can be selected without in main LCD affecting the thermostat programming • Selection of time or actual room temperature in main LCD display –...