D12 Firmware Update - d&b audiotechnik D12 Software Manual

Firmware v2.x.x
Hide thumbs Also See for D12:
Table of Contents

Advertisement

Fig. 9: SERVICE connector (D-SUB 9)
Fig. 10: 1:1 RS232 connection between
D12 and PC
D12 Software manual (Firmware V2.x.x)

3. D12 Firmware update

A firmware update will erase all user settings of the device. The device
Note:
name and the log files will be kept.
The operating software – firmware – can be updated in two different
ways.
1.
Firmware update of a single amplifier via serial interface using the
dbUpdate software program.
2.
Firmware update of multiple amplifiers via the d&b Remote network
(CAN-Bus) using the R10 Service software.
In addition, the d&b Firmware Installer is required.
All required software packages can be downloaded from the d&b
website at: www.dbaudio.com.
3.1
Firmware Installer
The Firmware Installer is a software program used to archive the
firmware files for the d&b amplifiers to a desired directory on your
computer. During the update procedure these firmware files will be
accessed either by D6-D12-dbUpdate or R10.
3.2
D12 Firmware update via D6-D12-dbUpdate
D6-D12-dbUpdate is a control software for loading new firmware
and/or loudspeaker setups into the D12 amplifier.
To execute a firmware update the computer must be fitted with an
RS 232 interface (serial port) and a RS 232 extension cable must be
used (D-SUB 9 f/m cable with one to one connections between pins 2, 3
and 5).
Pin
2
3
5
Tab. 5: D-SUB 9 pin assignment on d&b devices
Please consult the computer manual for the pin configuration of an
RS 232 port that uses a D-SUB 25 connector.
3.3
D12 Firmware update via CAN-Bus and R10
Using the d&b Remote network and the R10 Service software a
firmware update can be carried out via CAN-Bus. R10 allows to update
the firmware of multiple devices connected to the network at one time.
Notes:
For further information on R10 and the firmware update via CAN-Bus
please refer to the R10 manual.
A detailed description of remote control via CAN-Bus is given in the
technical information TI 312 (d&b code D5312.E.).
(5.2EN)
Signal
Remark
RxD
TxD
GND
Signal ground
Page 33 of 36