8.8 Disassembly of core unit, Drange
8.8.1 General disassembly
The core unit has to be removed from the platform at first (see according chapter "plat
form disassembly"). It is possible to perform a general disassembly of the core unit with
intact hose and wire connections to the platform (for repair, leakage check etc.).
Remove outlet
1. Open closing handle.
2. Press outlet (5) sidewards by hand carefully.
3. Insert disassembly tool into gap between outlet and right side panel (4).
R E P A I R S
Citiz service manual
After general disas
sembly of the core
unit a repairing/serv
ice holder device is helpful
for further repair work.
The disassembly tool
is necessary for
removing outlet and
side panels undamaged.