Download Print this page

Sealey RS103.V3 Instructions page 2

Roadstart units

Advertisement

DO NOT operate in vicinity of flammable liquids or gases.
8
DO NOT recharge the unit with plugs or attachments that are damaged. Replace such items immediately.
8
DO NOT use this product to perform a task for which it is not designed.
8
DO NOT store the unit in damp or wet locations or where the temperature may exceed 50°C.
8
DO NOT submerge the unit in water.
8
DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.
8
DO NOT leave the unit in a totally discharged state for an extended period of time as this may result in permanent damage.
8
DO NOT cross-connect the power leads from the RoadStart to the battery. Ensure that positive is to positive and negative is to negative.
8
Ensure that the unit is fully charged before storage.
9
1.3.
ELECTRICAL SAFETY (with respect to mains chargers)
WARNING! It is the user's responsibility to check the following:
You must check the AC adaptor to ensure that it is safe before using. You must inspect the power supply lead, plugs and all electrical
connections for wear and damage.
You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices. An RCCB (Residual Current
Circuit Breaker) should be incorporated in the main distribution board. We recommend that an RCD (Residual Current Device) is used
with all electrical products.
It is particularly important to use an RCD with portable products that plug into an electrical supply not protected by an RCCB. If in doubt
consult a qualified electrician. You can obtain a Residual Current Device through your Sealey stockist.
You must read and understand instructions concerning electrical safety.
1.3.1.
The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
person, using a Portable Appliance Tester (PAT), at least once a year.
1.3.2.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance and
the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.
1.3.3.
DO ensure that the insulation on all cables and the product itself is safe before connecting to the mains power supply.
DO ensure that cables are always protected against short circuit and overload.
1.3.4.
1.3.5.
DO regularly inspect power supply, leads, plugs for wear and damage and power connections to ensure that none is loose.
1.3.6.
DO check product voltage is the same as power supply to be used and check that all fused plugs are fitted with the correct capacity
fuses.
2. INTRODUCTION
RS1.V5 & RS102.V4
Composite case with integral battery clip storage and carry handle. LED battery condition and charge indicators. Test cycle button gives the true
battery indication. 230V Charger with automatic power cut-off prevents damage to battery whilst charging from the mains. Fitted with 12V power
socket that will accept any 12V device with a vehicle accessory socket plug. Supplied with mains charger.
RS103.V3
Composite case with integral clip storage and carry handle. Two batteries connected in parallel give high peak and cranking currents. LED
battery condition indicators. Fitted with 12V power socket that will accept any 12V device with a vehicle accessory socket plug. Supplied with
mains charger.
3. SPECIFICATION
Models: ................................. RS1.V5 ...................... RS102.V4 .................. RS103.V3
Cold Cranking Amps: ............. 300A ........................... 600A ........................... 1000A
Peak Amps: ........................... 1000A ......................... 1600A ......................... 3200A
Voltage:.................................. 12V ............................ 12V ............................ 12V
Auxiliary Output: .................... 12V ............................ 12V ............................ 12V
Cable & Clamp Length: ......... 0.5mtr ......................... 1.0mtr ......................... 1.8mtr
Weight: .................................. 7.68kg ........................ 9kg ............................. 17.08kg
Starting Capacity Petrol: ........ Up to 2ltr .................... Up to 3.5ltr (6cyl) ....... Up to 5ltr (8cyl)
Starting Capacity Diesel: ....... 2ltr (4 cylinder) ........... 3ltr (4 cylinder) ........... 3.5ltr (6 cyl)
fig.1
© Jack Sealey Limited
RS1.V5
RS102.V4
Original Language Version
(Key to figs.1 & 2)
1) Positive Battery Clamp
2) Flexible Heavy Duty Copper Cable
3) Charging Point
4) 12Vdc Output Socket
5) Test Button
6) Amber Led Charging Indicator
7) Red Power Level Led Indicators
8) Green Fully Charged Led Indicator
9) Flexible Heavy Duty Copper Cable
10) Negative Battery Clamp
11) Safety Storage Holster
12) Heavy Duty Plastic Case
13) Safety Storage Holster
RS1.V5 RS102.V4 RS103.V3 Issue 7 (3,4) 29/4/19
fig.2
RS103.V3

Advertisement

loading

This manual is also suitable for:

Rs102.v4Rs1.v5