Item
Condition
27. DTMF
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide 5k
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Wide 4k
3) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
28. Courtesy
1) Channel: 3 (Center)
Tone
Wide/Narrow: Analog Wide 5k
Deviation
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Wide 4k
3) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
29. TD
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide 5k
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 3kHz
De-emp: OFF
Detector: +peak, –peak
AG setting
: 0.1kHz/0.5Vp-p (177mVrms)
2) Channel: 3 (Center)
Wide/Narrow: Analog Wide 4k
3) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
30. Transmit
1) Channel: 3 (Center)
Audio Input
Wide/Narrow: Analog Wide 5k
(TA)
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: +peak, –peak
AG setting
: 1kHz/280mVrms
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
CONTROL
AG
I/O jack TD
DVM
(pin 8)
Deviation
Rear
TX ANT
meter
CONTROL
AG
I/O jack TA
DVM
(pin 9)
NXR-700
Adjustment
Unit
Parts
Method
PC
±2.85kHz
ADJ
±2.4kHz
±1.50kHz
PC
±1.00kHz
ADJ
±0.8kHz
±0.50kHz
PC
±0.75kHz
ADJ
±0.75kHz
±0.75kHz
PC
±3.00kHz
ADJ
Specifi cations / Remarks
±0.05kHz
Connect the deviation me-
ter to the TX ANT end via
the ATT.
±0.05kHz
±0.05kHz
±0.05kHz
Connect the deviation me-
ter to the TX ANT end via
the ATT.
±0.05kHz
±0.05kHz
±0.02kHz
Connect the deviation me-
ter to the TX ANT end via
the ATT.
±0.02kHz
±0.02kHz
±0.03kHz
Connect the deviation me-
ter to the TX ANT end via
the ATT.
89