NXR-700
Item
Condition
23. QT
2) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide 4k
3) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
24. DQT
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide 5k
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 3kHz
De-emp: OFF
Detector: Peak hold
2) Channel: 3 (Center)
Wide/Narrow: Analog Wide 4k
3) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
25. CW ID
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide 5k
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: +peak, –peak
2) Channel: 3 (Center)
Wide/Narrow: Analog Wide 4k
3) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
26. Test Tone
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide 5k
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Wide 4k
3) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
88
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Adjustment
Unit
Parts
Method
PC
±0.6kHz
ADJ
±0.35kHz
PC
±0.75kHz
ADJ
±0.6kHz
±0.35kHz
PC
±2.00kHz
ADJ
±1.6kHz
±1.00kHz
PC
±3.00kHz
ADJ
±2.4kHz
±1.50kHz
Specifi cations / Remarks
±0.05kHz
±0.05kHz
±0.05kHz
Connect the deviation me-
ter to the TX ANT end via
the ATT.
±0.05kHz
±0.05kHz
±0.05kHz
Connect the deviation me-
ter to the TX ANT end via
the ATT.
±0.05kHz
±0.05kHz
±0.05kHz
Connect the deviation me-
ter to the TX ANT end via
the ATT.
±0.05kHz
±0.05kHz