Water Inlet Assy; Water Temperature Sensors - Bosch T5600S 12 D 23 Training And Service Information

Low nox instantaneous gas water heater / room sealed pressurized gas water heater for indoor installation
Hide thumbs Also See for T5600S 12 D 23:
Table of Contents

Advertisement

4.7 Water Inlet Assy

The inlet water valve contains the water connection of ¾" that integrates also the filter and
the flow restrictor according country characteristics.
Flow rate valve / Filter
The inlet water valve contains the filter and is acessible removing screw nº1 and pulling out the
valve with know nº2.

4.8 Water temperature sensors

The outlet and inlet water temperature is measured by a 8.5 kΩ NTC (outlet) and 50 kΩ
NTC (inlet). Both NTC measures temperature and are connected to different cable colors
and connectors in the control unit.
Page 17 from
43
Pict.21 – Thermal Fuse detail
Pict.22 – Inlet flow restrictor with filter
Pict.23 – Cold / Hot Temperature sensor
6 720 887 547 "SM FP_ErP MPP Europe 2018/08 en"