Burner
Burner
segment 1
segment 2
SV1
SV2
MV1
SV
Pict.16 – Gas valve / burner scheme for MPP
Pict.17 – Schematic view of 3 power levels

4.6 Heat Exchanger

The copper heat exchanger has a special configuration to ensures sealed combustion and
optimized heat transfer from the flame heat to the water that flows through the copper
pipes.
Page 15 from
43
6 720 887 547 "SM FP_ErP MPP Europe 2018/08 en"