Sensalign Laser Ali 4.910 - PRÜFTECHNIK ROTALIGN Ultra iS Operating Handbook

Shaft alignment
Table of Contents

Advertisement

ROTALIGN Ultra iS Shaft handbook
2.3 sensALIGN laser
The semiconductor laser diode emits a ray of red light (wavelength 635 nm) which
is visible where it strikes a surface. The Class 2 laser beam is emitted with a diameter
of approx. 5 mm (3/16").
sensALIGN laser is turned on by pressing and holding the on/off switch briefly. The
"beam active" LED lights red.
With sensALIGN laser on, DO NOT stare into the laser beam!
With sensALIGN laser on, DO NOT stare into the laser beam!
The beam is adjusted during set-up by changing its vertical and horizontal angles
using the position thumbwheels, so that the beam strikes the sensALIGN sensor lens
perpendicular to the lens surface.
sensALIGN laser is water and dust resistant (IP 65). The internal optics and electronics
are internally sealed, preventing possible contamination.
Information regarding the battery status, the rotational angle, the temperature and
the serial number of the sensALIGN laser are transmitted through the laser beam into
sensALIGN sensor. This information is further relayed to ROTALIGN Ultra iS computer.
sensALIGN laser ALI 4.910 is powered using sensALIGN rechargeable battery
ALI 4.960 a 3.7 V 1.6 Ah Lithium Polymer rechargeable battery. The rechargeable
battery is attached to the laser and is to be charged only using the sensALIGN charger/
adapter ALI 4.651-I, and is possible only when the battery is attached to the laser.
Vertical beam position
thumbwheel (yellow)
20
Battery status LED
Sliding dust cap
(yellow)
Laser aperture
ALI 4.910
Beam active LED
WARNING
Clamping lever (depicted
here in the 'open' position)
On/Off push button switch
Horizontal beam position
thumbwheel (yellow)
Charger/adapter
socket (shown covered)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROTALIGN Ultra iS and is the answer not in the manual?

Questions and answers

Monika Takkel
February 2, 2025

Hi, I have the charger plugged in to the Rotalign Ultra iS and the red dots are together as mentioned in the manual but its not charing the unit. The light is not flashing and the batter is not getting charged. I dont know what to do with it .

1 comments:
Mr. Anderson
February 10, 2025

The PRÜFTECHNIK ROTALIGN Ultra iS may not be charging despite the charger being plugged in and the red dots being aligned due to one of the following reasons:

1. Defective Battery – If the battery is faulty, it may not accept a charge. The manual advises against shipping defective batteries and suggests contacting a representative for further assistance.

2. Incorrect Charger – The battery should only be charged using the ALI 12.651-I charger. Using a different charger might prevent proper charging.

3. Battery Not Properly Connected – Ensure the battery is securely installed inside the computer.

4. Extended Period of Disuse – If the unit has not been used for a long time (a month or more), the battery may need to be removed and reinserted to reset the charging process.

5. Damaged Charging Port or Cable – Check if the charging port or cable is damaged, preventing proper connection.

If the issue persists, further troubleshooting or battery replacement may be needed.