Trouble shooting
6.7 Fault code

Overview

Fault code
Function group
1000 - 1999
Travel system
2000 - 2499
Steering
2500 - 2999
Remote controls
5000 - 5499
Diesel engine
7000 - 7499
Input codes for machine parameterization
7500 - 7999
Operating hour meter, load spectrum (input codes)
8000 - 8999
Severe software error
9000 - 9998
External IO nodes, joysticks, data collectors (CAN communication and hardware de-
fects )
9999
Unknown fault, displayed value higher than +/- 10000, automatic output by the BMFSA

Fault codes of travel functions

Code
Fault reaction
1030
Output is switched
off, function
no longer possible
1031
Output is switched
off, function no long-
er possible
1032
Output is switched
off, function no long-
er possible
106
Description of fault
Output valve travel-
ling forward, Y 16
Too high current flow
out of this output Out-
put was switched off!
Output valve travel-
ling forward, Y 16
Short-circuit current
flow out of this output
Output was switched
off!
Output valve travel-
ling forward, Y 16
No or too low current
flow out of this output
BOMAG
Possible cause
Excessive current
flow in current path,
probably because of
a defective coil or a
short circuit to
ground
Short circuit to
ground in the current
path
Lines rubbed through
Valve defective
Wire breakage in cur-
rent path
Current path con-
nected to +12V
Terminal
Input
on BLM
code for
diag-
nose
X3:22
-
X3:22
-
X3:22
1030
1031
1032
BMP 8500