installation and external connection

EXTERNAL CONNECTION

Wiring Diagram
Buzzer Control In
LED Control In
CONTROLLER
Wiegand Data 0 Out
Wiegand Data 1 Out
Item
Power Supply Unit
Wiegand Connection
LED Control
Buzzer Control
10_
Installation and External Connection
SSA-R1001/SSA-R1101
Blue
Yellow
Green
White
Red
DC +12V
POWER
Connect the DC+12V to the red line.
Connect GND to the black line.
Connect the green line of the product to the Wiegand D0 input port of the controller.
Connect the white line of the product to the Wiegand D1 input port of the controller.
To control the LED indicators, connect the yellow line to the output port (relay) of the controller.
To control the built-in buzzer, connect the blue line to the output port (relay) of the controller.
PC
Black
GND
Cable Color