Advent XT2 
Assisted Living Call Management System 
_________________________________________________________________________________________________ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Tynetec, a business unit of Legrand Electric Ltd 
Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF.  
 
T: +44 (0) 1670 352 371   www.tynetec.co.uk  
 
_______________________________________________________________________________________________________________________ 
 
 
Trusted Technology  
 
Caring for People 
Installation Manual 
Tynetec operates a policy of continual product improvement and 
reserves the right to modify the specification of its products. 
If any variation to the details in this document are suspected please 
IP‐DECT 
contact Tynetec's Technical Support.
 
Doc No. FM0814 issue 2   
  

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Advent XT2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tynetec Advent XT2

  • Page 1                                         Tynetec operates a policy of continual product improvement and  reserves the right to modify the specification of its products.     If any variation to the details in this document are suspected please  contact Tynetec’s Technical Support.             Tynetec, a business unit of Legrand Electric Ltd  Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF.     T: +44 (0) 1670 352 371   www.tynetec.co.uk     _______________________________________________________________________________________________________________________      Trusted Technology  ...
  • Page 2: Table Of Contents

    CONTENTS      Section  Topic  Page    1  Product Overview 3  2  Important Safety Instructions  4  3  Regulatory Information  5  4  Maintenance & Care 5  5  DECT Overview  6  6  Related Documentation  7  7  Site Wiring Requirements  8  8  7202/7212 DECT Handsets  10  9  Multi Charger & PSU  11  10  IP‐DECT Server 400 & IP‐DECT Base Station  12  11  IP‐DECT Server 6500  14  12 ...
  • Page 3: Product Overview

    1.  PRODUCT OVERVIEW    The Digitally Enhanced Cordless Telephone (DECT) system allows 2‐way voice communications with  residents via Advent XT2 warden call system and between staff, both internally and externally if required.   When the Advent XT2 is operating in Onsite Mode all alarm calls are reported via DECT system. When the  phone rings the caller will be identified on the display (provided the phone book memory is programmed),  when answered a voice message will announce the call type and channel ID before a speech link is opened.    The size/complexity of the building and/or the number of DECT handsets required will determine which  one of 3 possible DECT systems is installed;    1. IP‐DECT 400 Single‐Cell system for small installations  2. IP‐DECT 400 Multi‐Cell system for most average‐sized installations  3. IP‐DECT 6500 system for large or complex installations    All DECT systems use the same handsets, it’s the Server type and number of Base Stations/Repeaters that  are needed to achieve site coverage and how they are configured which differs. The type of DECT system  and positioning of Base Stations/Repeaters will be determined by a site survey prior to commencing the  installation.    All Base Stations are star‐wired from a central PoE Data Switch on Cat5e cable (max length 100 metres).  Repeaters operate wirelessly but require connection to a battery backed 12V DC power supply. In the event  of a mains power failure a UPS (Uninterruptable Power Supply) will maintain operation of the DECT system.     The IP‐PBX allows the DECT handsets to access an outside line to make/receive telephone calls and  integrate with the Advent XT2 warden call system. The DECT system can be setup so all the warden call  system events are always alerted to all handsets, or day/night groups can be set so different handsets can  be alerted depending on the time of day. The handsets can be configured into zones so alerts are only  notified to the staff responsible for specific areas.               ...
  • Page 4: Important Safety Instructions

    2.  SAFETY INSTRUCTIONS    Read and understand these instructions before use. Refer to the Manufacturers installation and user  guides for more information (see section 6 of this manual). Keep all instructions for future reference.  Take care when working on step ladders during installation or service.  Isolate the mains supply before removing covers.    Do not disassemble any part of the system or attempt to repair it yourself.   No user serviceable parts inside. Refer all servicing to qualified service personnel.    PSU’s should only be connected to a 220‐240VAC 50/60Hz mains supply. If you are unsure of the type  of power supply consult your local power company.    Danger of explosion if rechargeable batteries are incorrectly replaced. Use only Manufacturer  approved batteries as specified in this manual.     Only use Manufacturer approved cable during installation. See section 7 of this manual for details of  cable type, recommended colour code and cable length restrictions.      DECT products should be located at least 5 metres away from any other electronic equipment.   Failure to provide this separation may result in reduced radio range.      Do not locate DECT products above a radiator or other heat source.     Do not expose DECT products to direct sunlight.     Do not submerge DECT products in water and do not use in damp or humid conditions.      Do not drop or expose DECT products to high vibration or shock.      Do not expose DECT products to dripping or splashing water.   Liquids can cause a failure and/or a fire hazard.    Clean DECT products with a damp cloth and a non‐abrasive cleaning product. Polish with a dry duster.  DO NOT use a wet cloth.    ...
  • Page 5: Regulatory Information

    3.  REGULATORY INFORMATION      This symbol on the product indicates it complies with all relevant EU Directives as required by law e.g.  Radio & Telecommunication Terminal Equipment (RTT&E), Safety of Information Technology  Equipment (LVD), Electro Magnetic Compatibility (EMC) and Restriction of Hazardous Substances RoHS.  See the Specification for each individual product in section 19 onwards for relevant Approvals.  A copy of the complete Declaration of Conformity is available from Tynetec.      This symbol on the product indicates it is classed as Electrical or Electronic Equipment and should not  be disposed of with other commercial waste at the end of its working life.    The Waste of Electrical and Electronic Equipment (WEEE) Directive (2012/19/EU) has been put in place  to recycle products using the best available recovery and recycling techniques to minimise impact on  the environment, treat hazardous substances and avoid increasing landfill.    For product disposal please contact your supplier and check the terms and conditions of the purchase  contract and ensure this product is not mixed with other commercial waste for disposal.       This symbol on batteries indicates separate collection. Batteries contain chemicals that can be    hazardous to health and the environment and should not be disposed of in the waste bin.     The EU Directive (2006/6/EC) has been put in place to ensure the safe disposal and recycling of  batteries.            Return used batteries to your supplier or drop‐off at your local municipal waste recycling depot.          NTENTS   4.  MAINTENANCE & CARE ...
  • Page 6: Dect Overview

    5.  DECT OVERVIEW    The maximum theoretical range for any DECT system is 500 metres under ideal conditions, in practice the  range will rarely exceed 300 metres due to reflections from nearby buildings, trees, water, etc.     Obstructions inside buildings such as walls and floors will reduce the range, some construction materials  such as foil backed plasterboard, reinforced concrete or stone walls will reduce range further.     Environmental conditions such as high levels of transmission at nearby frequencies or emissions from other  electrical equipment may also reduce range.     Clear line‐of‐sight will give maximum radio coverage, it is impossible to state a specific indoor range in  advance of a site survey; however, as a guide you can usually achieve 50 metres radius from the  Server/Base Station or Repeater.    Locating the Server/Base Station as high and free from immediate obstruction as possible will help to  maximise its range. Even if the Server/Base Station is placed in the optimum position it may not always  achieve coverage in the most remote corners, if this is the case then additional Repeaters will be required.    Repeaters are generally placed in a star configuration around the Server/Base station; however, it is  possible to extend the coverage in one direction with up to 3 repeater jumps. A site survey will be required  to establish the best DECT system and Base/Repeater configuration required.     The Server, Base Stations and Repeaters should always be located at least 5 metres away from the Advent  XT2 controller, NTR’s or any other electrical equipment to avoid the risk of interference.    All DECT products must be sited in a dry secure area; they are NOT suitable for outdoor locations.          AVOID LOCATING DECT PRODUCTS…         WITHIN 5 METRES OF  DIRECTLY ABOVE A ...
  • Page 7: Related Documentation

    6.  RELATED DOCUMENTATION    This manual provides general information regarding the installation of the DECT telephone system.  For more detailed information refer to the Spectralink installation and user guides.  SPECTRALINK DOCUMENTS   You can request copies of the documents listed below from Tynetec’s customer support.  Tynetec Engineers can download them from the Legrand Dialeg 365 UK AL&H Document Library.   Alternatively download direct from Spectralink;   https://support.spectralink.com/products?qt‐product_finder_tabs=1&type=All       Spectralink 7202/12 Handset quick start guide   Spectralink 7702/12 Handset user guide   Spectralink Handset Management user guide   Spectralink Handset Battery information guide   Spectralink Handset Multi Charger installation guide   Spectralink Integrator Messaging Discovery document   Spectralink IP‐DECT Server 400/6500 installation & configuration guide    Spectralink IP‐DECT Server 400/6500 synchronization & deployment guide    Spectralink IP‐DECT Base Station installation guide     Spectralink DECT Repeater installation guide    Spectralink Base Stations or Repeaters?    Use the link below to download the DECT Repeater service tool software:  https://support.spectralink.com/products/dect/spectralink‐dect‐repeater      ...
  • Page 8: Site Wiring Requirements

    7.  SITE WIRING REQUIREMENTS    IP-DECT 400 SINGLE-CELL SYSTEM       spectralink ____________________________________________________________________________________ IP-DECT 400 MULTI-CELL SYSTEM   spectralink ____________________________________________________________________________________ IP-DECT 6500 SYSTEM         spectralink                         Doc No. FM0814 issue 2 Page 8     ...
  • Page 9   Cat5e Cable (Max 100m)        Make all 8 connections    2m Patch Lead  2m Patch Lead            WALL SOCKET FROM REAR  PIN No.  Cat5e WIRE COLOUR  RJ45 Wall Socket:         White/Orange Tynetec Part No. P10280    2  Orange      3  White/Green  Surface Backbox:     Blue Tynetec Part No. O15090    5  White/Blue    6  Green  2m Patch Lead:   ...
  • Page 10       UK Plug‐top     Desktop         Power Supply         Charger              ACCESSORIES & SPARES     Spectralink Ref.  Tynetec Part No.  Product     8474 3428  W03051  Spare Battery (1170mAh)   0231 9520  W03065  Safety Line   0231 9701  W03066  Carry Case   0231 9597  W03067  Belt Clip  ...
  • Page 11: 7202/7212 Dect Handsets

          Link Cable for connecting    up to 3 Charger Blocks                        PART NUMBERS   Spectralink Ref.  Tynetec Part No.  Product       0250 9400  W03034  Spectralink Multi Charger (Inc. Link Cable)   0250 9501  W03043  Spectralink Multi Charger UK PSU         Refer to the Spectralink Handset Multi Charger installation guide (see section 6).     ...
  • Page 12: Ip-Dect Server 400 & Ip-Dect Base Station

    10.  IP‐DECT SERVER 400 & IP‐DECT BASE STATION     The IP‐DECT Server 400 controls the IP‐DECT Base Station(s) and manages the IP interface to an optional IP‐ PBX. The communication protocol between the IP‐DECT Server 400 and the IP‐PBX is SIP. The IP‐DECT  Server 400 uses the wireless band ETSI (1880‐1900 MHz), referred to as 1G8.    The IP‐DECT Server 400 can be deployed as either a single‐cell or multi‐cell solution. The single‐cell option is  easy to deploy for a small scheme, where there is the need for more users or coverage of a larger area then  the multi‐cell solution can be used with up to 3 additional IP‐DECT Base Stations.      The IP‐DECT Base Station has 12 simultaneous traffic channels (32Kbits/s). The IP‐DECT Base Station  controls the traffic in the air and works as the link between the DECT handsets and the IP‐DECT 400 Server.     IP‐DECT 400 Servers and Base Stations are housed in the same ABS enclosure; always check the Model No.  label on the rear of the unit to be sure of which product you are looking at;      Spectralink Ref.  Tynetec Part No. Product     0234 4500  ZXT503 IP‐DECT Server 400 (Single‐Cell)   0234 4500*  ZXT504 IP‐DECT Server 400 (Multi‐Cell)   0233 7400  ZXT536 IP‐DECT Base Station   *the Multi‐cell version has an additional licence applied during manufacture        Surface Mount ABS Enclosure ...
  • Page 13 10. IP‐DECT SERVER 400 & IP‐DECT BASE STATION     RESET BUTTON You can restart or reset the IP‐DECT Server/Base Station by pressing the RESET button on the bottom face,  see the table below for the 2 possible actions;    Press Button  Action Short press (2‐5 Secs)  Server/Base Station restarts when the button is released  Long press (5‐9 Secs) until front LED  Reset to factory defaults (original IP setting and empty user  flashes red then release button  data base) and restart.    INSTALLATION The IP‐DECT Server 400 (Single‐Cell and Multi‐Cell), IP‐DECT Base Stations and 2/4 Channel DECT Repeaters  are all housed in the same type of enclosure and have the same fixing centres.            FRONT                 REAR      100mm  64mm       28mm      ...
  • Page 14: Ip-Dect Server 6500

    11.  IP‐DECT SERVER 6500     The IP‐DECT Server 6500 controls the wireless infrastructure; it manages Media Resources, Base Stations,  Repeaters and the IP interface to the Matrix IP‐PBX. The communication protocol between the IP‐DECT  Server 6500 and the IP‐PBX is a SIP line interface.     The IP‐DECT Server 6500 provides the DECT solution for a large geographical area and/or a large number of  mobile users. The modular nature of the IP‐DECT 6500 Server makes it easy to increase the number of voice  channels with the Media Resource and/or geographical coverage with additional IP‐DECT Base stations.         19” Rack Mount Steel Enclosure    440 x 199 x 44mm (WxDxH)                        SYSTEM CAPACITY    Max No. of IP‐DECT Base Stations: 512   Max No. of simultaneous calls on each IP‐DECT Base Station: 11   Max No. of Repeaters on each IP‐DECT Base Station: 3   Max No. of Media Resources: 32   Max No. of simultaneous calls with 1 Media Resource: 32   Max No. of simultaneous calls with 32 Media Resources: 1024 ...
  • Page 15: Dect Repeater

    12.  DECT REPEATER     DECT Repeaters are used to extend the wireless coverage area in a DECT network. The DECT Repeater  provides a larger geographical spread of the traffic channels and increases the coverage area but it does  not increase the number of channels available. The DECT Repeater is normally used in areas with limited  coverage e.g. long hallways, stairwells and corridors.    DECT Repeaters are available with either 2 or 4 voice channels. The Repeater is wireless with no connection  to the DECT Server or Base Station; however, it does need connection to a battery backed power supply.     2 Channel and 4 Channel DECT Repeaters are housed in the same ABS enclosure; always check the Model  No. label on the rear of the unit to be sure of which product you are looking at;      Spectralink Ref.  Tynetec Ref. Product     0244 1100  ZXT512 2 Channel Multi‐Cell Repeater   0233 4601  ZXT544 4 Channel Multi‐Cell Repeater         Wall Mount Keyhole    Surface Mount ABS Enclosure  Fixings on Rear     100 x 100 x 30mm (HxWxD)      Status LED  ...
  • Page 16: Dect Repeater Psu

    13. DECT REPEATER PSU     The 12V/2A Boxed PSU (Tynetec Part No. W00525) requires connection to the mains supply.      Boxed PSU          Green Power LED    Red Fault LED    Hinged/Removeable Lid       Wall Mounted Enclosure    200 x 230 x 80mm (HxWxD)          INSTALLATION Mains Connection  Undo the lid fixing screw and open the lid.     Note: if the lid is removed ensure the Safety Earth is re‐connected.    Colour   Terminal Fix the power supply unit to the wall using the 3 holes “A” as shown below.  Brown    Connect the mains supply to the mains terminals using the colour code   Blue  in the table alongside.  Green/Yellow   ...
  • Page 17 Power Supply  Rechargeable Battery                The rechargeable battery should be removed and tested by a Service Engineer on an annual basis and  replaced every 3‐5 years.    With the battery disconnected; check the charge voltage across the battery leads is between 13.6V DC and  14.2V DC (13.8V nominal).    If the battery shows any signs of damage, swelling or leakage during an annual inspection it should be  replaced immediately.    Only replace with the Manufacturers Approved battery type:  Yuasa NP3.4‐12: 12V 3.4Ah Sealed Lead Acid Rechargeable Battery   Replacement batteries are available from Tynetec; order Part No. F00040  IMPORTANT: always mark the battery with the date it was replaced for reference on future Service visits.         See section 3 of this manual for Regulations regarding the safe disposal of used batteries.                             ...
  • Page 18: Matrix Ip-Pbx

                                        Icon Ref.  Tynetec Ref. Product     NE312 EU  ZXT556 Matrix Eternity NE312 IP‐PBX (8 IP Ports)    NE312 EU + NE‐IP8  ZXT557 Matrix Eternity NE312 IP‐PBX (16 IP Ports)                   ...
  • Page 19  Office Tel Line  Battery Backed PSU    Matrix   Advent XT2 Line 1     2 Channel Multi Cell Repeaters     IP‐PBX  Advent XT2 Line 2          240V CLI Desk Telephone    AC           See Tynetec Drg No. ZXT900 sheet 7 for detailed connections    PART NUMBERS     Part No.  Description  Notes      ZXT548  700VA UPS  1 per site  ZXT556  Matrix Eternity IP‐PBX (8 IP Ports)  1 per site (use ZXT557  for 9+ DECT Handsets)  ZXT557  Matrix Eternity IP‐PBX (16 IP Ports)  ZXT502 ...
  • Page 20 CO3 ‐ connect to an external telephone line using the RJ11/BT lead provided.   SLT1 ‐ connect to the CLI desk telephone via a BT master socket (cut plug off the RJ11/RJ11 lead provided).   ETHERNET ‐ connect to the PoE injector using the RJ45 patch lead provided.    The Matrix must have its IP address set to 192.168.0.2, it’s factory programmed so all incoming lines ring all  extensions. If an incoming line is to ring specific extensions then the Matrix must be reconfigured.    Note; in the event of a mains failure i.e. if the UPS batteries run flat or if a UPS is not fitted, the Matrix  connects CO1 to SLT1 and the Advent XT2 will only ring the CLI desk telephone.    IP-DECT SERVER 400 (SINGLE-CELL) PROGRAMMING The IP‐DECT Server 400 must have its IP address set to 192.168.0.3 and its Radio Part Number set to 3.  Refer to the manufacturers installation guide for full instructions ‐ see section 6.    ADVENT XT2 PROGRAMMING The PBX Ring Type must be enabled in the Advent XT2 programming – see the Onsite & General Setup  section of the Advent XT2 programming manual (Doc No. FM0815).    2 CHANNEL MULTI CELL REPEATERS A maximum of six 2 Channel Multi‐Cell Repeaters can be used with the IP‐DECT Server 400 Single‐Cell.  Repeaters require a power connection only; they communicate with the Server via low power radio signals  and do not require a line connection. To maintain DECT coverage during a mains failure all Repeaters must  be connected to a battery backed 12V DC PSU.     REPEATER POSITIONING Before installing power cables to Repeater positions, it is important that the optimum position for coverage  is established. Register the Repeater onto the IP‐DECT Server 400 then with the Repeater powered from a  battery walk away in the direction that cover is to be extended. When the red LED on the Repeater starts to  flash it is out of range and must be moved back towards the Server by a minimum of 5 metres before ...
  • Page 21: Ip-Dect 400 Single-Cell System Installation

    15.  IP‐DECT 400 SINGLE‐CELL SYSTEM INSTALLATION     REPEATER DEPLOYMENT RULES    A maximum of 6 Repeaters can be configured on an IP‐DECT Single‐Cell Server ‐ RPN 3   A maximum of 3 Repeaters can be configured in a chain   If you have up to 3 Repeaters they should be numbered: 67, 131 & 195 i.e. RPN 3 +64, +128 & +192   If you have more than 3 Repeaters they should be assigned one of the following: 35, 67, 99, 131,  163, 195 & 227    2 Repeaters cannot have the same number   See deployment examples below; RPN = the Radio Part Number     Server is shaded RED          Repeaters are shaded GREEN         Radio handover BLUE                  Single‐Cell Server  Repeater   RPN 3  RPN XX     1 REPEATER DEPLOYMENT   1 Repeater connected directly:       ...
  • Page 22 15. IP‐DECT 400 SINGLE‐CELL SYSTEM INSTALLATION     3 REPEATER DEPLOYMENT EXAMPLES CONTINUED…   3 Repeaters connected directly:            Repeater   RPN 131     Repeater  Single‐Cell Server    RPN 67  RPN 3      Repeater    RPN 195     Y‐shaped 3 Repeater deployment:            Repeater    RPN 131  ...
  • Page 23 15. IP‐DECT 400 SINGLE‐CELL SYSTEM INSTALLATION  5 REPEATER DEPLOYMENT EXAMPLES   1 chain of 3 Repeaters and 1 chain of 2 Repeaters; the Repeater connected to 35 needs to be +64 so this Repeater is numbered 99.                Repeater  Repeater  Single‐Cell Server Repeater Repeater Repeater    RPN 99  RPN 35 RPN 3  RPN 67 RPN 131 RPN 195      2 chains of 2 Repeaters and 1 single Repeater:            Repeater  Repeater    RPN 67 RPN 131   ...
  • Page 24 15.  IP‐DECT 400 SINGLE‐CELL SYSTEM INSTALLATION    6 REPEATER DEPLOYMENT EXAMPLES CONTINUED… 2 chains of 2 Repeaters and 2 single Repeaters connected directly:          Repeater   RPN 195                Repeater  Repeater  Single‐Cell Server Repeater Repeater    RPN 99  RPN 35  RPN 3  RPN 67 RPN 131               ...
  • Page 25 Battery Backed PSU           IP‐PBX    2 Channel Multi Cell Repeaters             CLI Desk Telephone    240V   AC     Max 6 Repeaters per PSU       See Tynetec Drg No. ZXT900 sheet 8 for detailed connections    PART NUMBERS     Part No.  Description  Notes      ZXT548  700VA UPS  1 per site  ZXT556  Matrix Eternity IP‐PBX (8 IP Ports)  1 per site (use ZXT557  for 9+ DECT Handsets)  ZXT557  Matrix Eternity IP‐PBX (16 IP Ports) ZXT549 ...
  • Page 26   Note; in the event of a mains failure i.e. if the UPS batteries run flat or if a UPS is not fitted, the Matrix  connects CO1 to SLT1 and the Advent XT2 will only ring the CLI desk telephone.    IP-DECT SERVER 400 (MULTI-CELL) PROGRAMMING The IP‐DECT Server 400 must have its IP address set to 192.168.0.3 and its Radio Part Number set to 3.  Refer to the manufacturers installation guide for full instructions – see section 6.    IP-DECT BASE STATION PROGRAMMING IP‐DECT Base Stations must have their IP addresses set 192.168.0.4/5/6 and Radio Part Numbers 4/5/6.  Refer to the manufacturers installation guide for full instructions – see section 6.    ADVENT XT2 PROGRAMMING The PBX Ring Type must be enabled in the Advent XT2 programming – see the Onsite & General Setup  section of the Advent XT2 programming manual (Doc No. FM0815).    2 CHANNEL MULTI-CELL REPEATERS A maximum of three 2 Channel Multi‐Cell Repeaters can be connected to the IP‐DECT Server 400 Multi‐Cell  plus three per IP‐DECT Base Station (total 12 per site). Repeaters require a power connection only; they  communicate with the Server/Base Station via low power radio signals and do not require a line  connection. To maintain DECT coverage during a mains failure all Repeaters must be connected to a battery  backed 12V DC PSU.    REPEATER POSITIONING Before installing power cables to Repeater positions, it is important that the optimum position for coverage  is established. Register the Repeater onto the IP‐DECT Server 400 then with the Repeater powered from a ...
  • Page 27 16. IP‐DECT 400 MULTI‐CELL SYSTEM INSTALLATION  REPEATER POWER CONNECTION Repeaters should be connected using 1.0 mm pair cabling, if CW1308 is being used then spare pairs can be  doubled‐up and/or looped back to form a ring circuit to reduce the voltage drop if necessary.     Battery Backed 12V DC PSU    Maximum 12 x 2 Channel Multi‐Cell Repeaters    (3 on Multi‐Cell Wireless Server + 3 per DECT‐IP Base Station)              240V    AC     Repeater Power Lead Colour Code     Use 1.0mm Cable  Max 100m     YELLOW = 12V    BLACK = 0V      REPEATER DEPLOYMENT RULES    A maximum of 3 Repeaters can be configured on an IP‐DECT 400 Multi‐Cell Server ‐ RPN 3   If you have up to 3 Repeaters on an IP‐DECT 400 Multi‐Cell Server they should be numbered: 67,  131 and 195 i.e. RPN 3 + 64, +128 and +192   A maximum of 3 Repeaters can be configured on an IP‐DECT Base Station ‐ RPN 4/5/6   If you have up to 3 Repeaters on an IP‐DECT Base Station they should be numbered as:   ...
  • Page 28: Ip-Dect 400 Multi-Cell System Installation

    16. IP‐DECT 400 MULTI‐CELL SYSTEM INSTALLATION    3 REPEATER DEPLOYMENT EXAMPLES   3 Repeaters connected in a chain:                Multi‐Cell Server/Base  Repeater  Repeater Repeater   RPN 3‐6  RPN +64  RPN 128 RPN +192   1 Repeater connected directly and 2 in a chain:                Multi‐Cell Server/Base  Repeater  Repeater Repeater   RPN 3‐6  RPN +64  RPN +128 RPN +192  ...
  • Page 29 17. IP‐DECT SERVER 6500 SYSTEM INSTALLATION    If full site coverage cannot be achieved using the IP‐DECT Server 400 multi‐cell option then the IP‐DECT  Server 6500 must be used. The standard IP‐DECT Server 6500 can expand up to 8 Base Stations, 24  Repeaters and 64 DECT handsets, larger systems are possible by adding additional Ethernet Switch’s to  increase the number of PoE Ports & Base Stations/Repeaters, contact Tynetec’s customer support for  advice.   DECT Handsets (64 standard)  16 Port Ethernet                Switch (8 x PoE)  700VA    UPS  240V    AC    IP‐DECT Base Stations (8 standard)  IP‐DECT     Server 6500  Office Tel Line  Advent XT2 Line 1  Repeaters (max 3 per Base Station = 24 standard)  Advent XT2 Line 2  Matrix     12V DC PSU        IP‐PBX    4 Channel Multi Cell Repeaters            CLI Desk Telephone    240V   AC    ...
  • Page 30   The Matrix must have its IP address set to 192.168.0.2, it’s factory programmed so all incoming lines ring all  extensions. If an incoming line is to ring specific extensions, then the Matrix must be re‐configured.  Note; in the event of a mains failure i.e. if the UPS batteries run flat or if a UPS is not fitted, the Matrix  connects CO1 to SLT1 and the Advent XT2 will only ring the CLI desk telephone.    IP-DECT SERVER 6500 PROGRAMMING The IP‐DECT Server 6500 must have its IP address set to 192.168.0.3.   Refer to the manufacturers installation guide for full instructions – see section 6 of this manual.    IP-DECT BASE STATION PROGRAMMING IP‐DECT Base Station IP addresses must start at 192.168.0.4 with RPN 4 and carry on sequentially.  Refer to the manufacturers installation guide for full instructions – see section 6 of this manual.    ADVENT XT2 PROGRAMMING The PBX Ring Type must be enabled in the Advent XT2 programming – see the Onsite & General Setup  section of the Advent XT2 programming manual (Doc No. FM0815).    4 CHANNEL MULTI-CELL REPEATERS A maximum of three 4 Channel Multi‐Cell Repeaters can be connected per IP‐DECT Base Station. Repeaters  require a power connection only; they communicate with the Base Station via low power radio signals and  do not require a line connection. To maintain DECT coverage during a mains failure all Repeaters must be  connected to a battery backed 12V DC PSU.    REPEATER POSITIONING Before installing power cables to Repeater positions, it is important that the optimum position for coverage  is established. Register the Repeater onto the IP‐DECT Base then with the Repeater powered from a battery  walk away in the direction that cover is to be extended. When the red LED on the Repeater starts to flash it ...
  • Page 31 17. IP‐DECT SERVER 6500 SYSTEM INSTALLATION    REPEATER POWER CONNECTION Repeaters should be connected using 1.0mm pair cable; if CW1308 is being used then spare pairs can be  doubled‐up and/or looped back to form a ring circuit to reduce the voltage drop if necessary.       Battery Backed 12V DC PSU    4 Channel Multi Cell Repeaters    (3 per IP 12 Channel Base Station)              240V    AC     Repeater Power Lead Colour Code     Use 1.0mm Cable  Max 100m      YELLOW = 12V BLACK = 0V      REPEATER DEPLOYMENT RULES    A maximum of 3 Repeaters can be configured on an IP‐DECT Base Station; RPN = IP Address    If you have up to 3 Repeaters on an IP‐DECT Base Station they should be numbered as:  Base Station No. “X” +64, +128 and +192. The first Base Station is No. 4, second No. 5 and so on…   A maximum of 3 Repeaters can be configured in a chain ...
  • Page 32: Ip-Dect 6500 System Installation

    17. IP‐DECT SERVER 6500 SYSTEM INSTALLATION  3 REPEATER DEPLOYMENT EXAMPLES   3 Repeaters connected in a chain:                IP‐DECT Base Station  Repeater  Repeater Repeater       RPN 4 →  RPN +64  RPN +128 RPN +192   1 Repeater connected directly and 2 in a chain:                IP‐DECT Base Station  Repeater  Repeater  Repeater   ...
  • Page 33: Specification: 7202 Dect Handset

    18. SPECIFICATION: 7202 DECT HANDSET    7202 DECT Handset    Manufacturer/Model No.  Spectralink 0260 0000   Tynetec Bundle Part No.  ZXT523 (includes handset, charger and PSU)  Radio Approval  EN 301 406  EMC Approvals  EN 301 489‐1, EN 301 489‐6  Safety Approval  EN 60950‐1  SAR Approval  EN 50360  Environmental Approvals  RoHS: 2002/95/EC, WEEE: 2002/96/EC  Drop Test  IEC 60068‐2‐31 (2008‐05)  Battery Type  1170mAh Li‐ion (replacement battery: Tynetec Part No. W03051)   Typical Battery Life  2 years or 500 charging cycles   Speech Time  Up to 22 hours (in economy mode)  Standby Time  Up to 141 hours  Display  Colour LCD  Languages  14: UK/FR/DE/ES/IT/NL/CZ/PL/DK/NO/SV/FI/PT/RU  Ingress Protection Rating  EN60529: IP54 (protected against dust splashing water)  Dimensions  149mm x 50mm x 28mm (HxWxD)   Weight  123 grams including battery   Operating Temperature Range  ‐10 C to +55...
  • Page 34: Specification: 7212 Dect Handset

    19. SPECIFICATION: 7212 DECT HANDSET    7212 DECT Handset    Manufacturer/Model No.  Spectralink 0261 0000   Tynetec Bundle Part No.  ZXT524 (includes handset, charger and PSU)  Radio Approval  EN 301 406  EMC Approvals  EN 301 489‐1, EN 301 489‐6  Safety Approvals  EN 60950‐1  SAR Approval  EN 50360  Environmental Approvals  RoHS: 2002/95/EC, WEEE: 2002/96/EC  Drop Test  IEC 60068‐2‐31 (2008‐05)  Battery Type  1170mAh Li‐ion (replacement battery: Tynetec Part No. W03051)   Typical Battery Life  2 years or 500 charging cycles   Speech Time  Up to 22 hours (in economy mode)  Standby Time  Up to 141 hours  Display  Colour LCD  Languages  14: UK/FR/DE/ES/IT/NL/CZ/PL/DK/NO/SV/FI/PT/RU  Ingress Protection Rating  EN60529: IP54 (protected against dust splashing water)  Dimensions  148mm x 50.4mm x 21.6mm (HxWxD)   Weight  115 grams including battery   Operating Temperature Range  ‐10 C to +55...
  • Page 35: Specification: Desktop Charger & Psu

    20. SPECIFICATION: DESKTOP CHARGER & PSU    Desktop Charger    Manufacturer/Model No.  Spectralink 8464 2493  Tynetec Part No.  W03033  Enclosure  White, desktop design, indoor use only  Dimensions  Base Diameter 89mm x 68mm High   Weight  134 grams     Desktop Charger Power Supply    Manufacturer/Model No.  Spectralink 8464 2601 UK  Tynetec Part No.  W03042  Safety Approvals  EN 60950, C‐Tick  Input Plug  UK BS1363  Input Voltage/Current  100‐240VAC 50/60Hz 400mA  Output Voltage/Current  6V DC 1.0A  Efficiency  Energy Star Level V (V2.0)  Standby Power  0.3 Watts Max  Max Power  6 Watts  Output Connector  Moulded 1.3mm Barrel Plug Centre Positive (3.5mm OD)  Output Cable   3 metres  Enclosure ...
  • Page 36: Specification: Multi Charger & Psu

    21. SPECIFICATION: MULTI CHARGER & PSU    Multi Charger Block    Manufacturer/Model No.  Spectralink 0250 9400  Tynetec Part No.  W03034  No. of Handsets per Block  5 max  No. of Blocks per PSU  3 max (15 handsets)  Link Cable  200mm long, fitted with 2 moulded 2.1mm Barrel Plugs (5.5mm OD)  Enclosure  White, desktop or wall mount, indoor use only  Dimensions  358mm x 63mm x 63mm (HxWxD)   Weight  450 grams     Multi Charger Power Supply    Manufacturer/Model No.  Spectralink 0250 9501 (FranMar FRA032‐S07‐4)  Tynetec Part No.  W03043  Safety Approvals  IEC/UL/EN 60950‐1  EMC Approvals  EN55022, EN6100‐3‐2, EN61000‐4‐2, EN55024  Protection  Electronic OVP, OLP & Short Circuit Protection  LED Indicator  Green: Supply Healthy  Input Voltage/Current  100‐240VAC 47‐63Hz 1.0A  Output Voltage/Current  6V DC 5A  Efficiency ...
  • Page 37: Specification: Ip-Dect Server 400

    22. SPECIFICATION: IP‐DECT SERVER 400    IP‐DECT Server 400 (Single‐Cell)    Manufacturer/Model  Spectralink 0234 4500   Tynetec Part No.  ZXT503  Radio Approvals  EN 301 406, FCC Rules CRF47 Part 6, ANSI C63.4  EMC Approvals  EN 301 489‐1, EN 301 489‐6  Safety Approvals   UL 60950‐1, EN 60950‐1  Environmental Approvals  RoHS: 2002/95/EC, WEEE: 2002/96/EC  Network Provisioning  RJ45 10/100 Mbps Ethernet Port, DHCP, NTP, LED Status indication  Protocol Support  SIP (Session Initiated Protocol)  System Architecture  12 wireless users/6 simultaneous calls  Typical Range  20‐50 metres indoor (300 metres outdoor)  Peak Transmit Power  250mW  Typical Receiver Sensitivity  ‐90dBm  Electrical Requirement  PoE Class 1 Device, Power over Ethernet (IEEE 803.3af), mode A&B   Typical Power Consumption  3 Watts  Power Input Port  FCC‐68 RJ11 6/6 Socket for optional 8V plug‐top PSU (if no PoE)  Enclosure   Grey‐White ABS (NCS 0502‐Y) wall mountable, indoor use only  Dimensions  100mm x 100mm x 38mm (HxWxD)   Weight  120 grams  ...
  • Page 38: Specification: Ip-Dect Server 6500

    23. SPECIFICATION: IP‐DECT SERVER 6500     IP‐DECT Server 6500    Manufacturer/Model  Spectralink 0235 0000   Tynetec Part No.  ZXT535  EMC Approvals  EN 55022, EN 55024:A‐A2, FCC Rules CRF47 Part 15, Class B digital device  Safety Approvals  UL 60950‐1, EN 60950‐1  Environmental Approvals  RoHS: 2002/95/EC, WEEE: 2002/96/EC  Network Provisioning  RJ45 10/100 Mbps Ethernet Port, DHCP, NTP  Protocol Support  SIP (Session Initiated Protocol)  System Architecture  64 users/32 simultaneous calls   Optional Licences  150/500/1500/4095 users/max 1024 simultaneous calls  Electrical Requirement  100‐240V AC 50‐60Hz  Typical Power Consumption  1.5A  Enclosure   18 SWG grey steel – 19” rack or wall mountable, indoor use only  Dimensions  440mm x 199mm x 44mm (HxWxD)   Weight  2354 grams   Operating Temperature Range  C to +40 C   Operating Humidity  20‐80% RH, Non‐condensing       ...
  • Page 39: Specification: Ip-Dect Base Station

    24. SPECIFICATION: IP‐DECT BASE STATION    IP‐DECT Base Station    Manufacturer/Model  Spectralink 0233 7400  Tynetec Part No.  ZXT536  Radio Approvals  EN 301 406, FCC Rules Part 15, IC Rules RSS213 Iss2  EMC Approvals  EN 301 489‐1, EN 301 489‐6,   Safety Approvals  UL 60950‐1, EN 60950‐1  Environmental Approvals  RoHS: 2002/95/EC, WEEE: 2002/96/EC  Network Provisioning  RJ45 10/100 Mbps Ethernet Port, DHCP, NTP, LED Status indication  Max No. of Speech Channels  12  Typical Range  20‐50 metres indoor (300 metres outdoor)  Peak Transmit Power  250mW  Typical Receiver Sensitivity  ‐90dBm  Electrical Requirement  PoE Class 1 Device, Power over Ethernet (IEEE 802.3af), mode A&B   Typical Power Consumption  2 Watts  Power Input Port  FCC‐68 RJ11 6/6 Socket for optional 8V plug‐top PSU (if no PoE)  Enclosure   Grey‐White ABS (NCS 0502‐Y) wall mountable, indoor use only  Dimensions  100mm x 100mm x 38mm (HxWxD)   Weight  120 grams   Operating Temperature Range  C to +40 C  ...
  • Page 40: Specification: Multi-Cell Repeaters

    25. SPECIFICATION: MULTI‐CELL REPEATERS    2 Channel Multi‐Cell Repeater    Manufacturer/Model No.  Spectralink 0244 1100  Tynetec Part No.  ZXT512  Radio Approvals  EN 301 406, FCC Rules Part 15/Subpart D RSS‐213  EMC Approvals  EN 301 489‐1, EN 301 489‐6  Safety Approvals  UL 60950‐1, EN 60950‐1  Environmental Approvals  RoHS: 2002/95/EC, WEEE: 2002/96/EC  Max No. of Speech Channels  2  Typical Range  20‐50 metres indoor (300 metres outdoor)  Peak Transmit Power  250mW  Typical Receiver Sensitivity  ‐90dBm  Power Input Port  FCC‐68 RJ11 4/4 Socket  Electrical Requirement  9V DC, 180mA   Typical Power Consumption  1.62 Watts  Enclosure   Grey‐White ABS (NCS 0502‐Y) wall mountable, indoor use only  Dimensions  100mm x 100mm x 30mm (HxWxD)   Weight  113 grams   Operating Temperature Range  C to +40 C   Operating Humidity ...
  • Page 41: Specification: Poe Injector

    26. SPECIFICATION: PoE INJECTOR     PoE Injector    Manufacturer/Model No.  Icon MIT‐07D  Tynetec Part No.  ZXT502  Network Protocol & Standards   IEEE 802.3af 10Base‐T Ethernet  Safety/Quality Approvals  NEI‐EMC‐1‐0507 126, NEI‐FCCE‐1‐0507 126  Data Rate  100Mbps   Network Interface  2 shielded RJ45   Network Ports  1 auto‐speed sensing 10/100 Mbps UTP Port with PoE  Status LED’s  AC Power (red)   Electrical Requirement  90‐264V AC 50/60Hz   Typical Power Consumption  0.2A @ 220V AC  Mains Lead  1.2 metres long with BS 1363 moulded non‐rewireable 13A UK Plug  Fuse Type/Rating  BS 1362 1” 240V AC 5A   Enclosure   White, wall mount, indoor use only  Dimensions  85mm x 76mm x 36mm (WxHxD)   Weight  138 grams   Operating Temperature Range  C to +60 C   Operating Humidity  10‐90% RH, Non‐condensing   ...
  • Page 42: Specification: 16 & 24 Port Ethernet Switches

    27. SPECIFICATION: 16 & 24 PORT ETHERNET SWITCHES    16 Port Ethernet Switch (8 PoE)    Manufacturer/Model No.  Netgear ProSAFE FS116P  Tynetec Part No.  ZXT549  Network Protocol & Standards   IEEE 802.3i 10Base‐T Ethernet, IEEE 802.3u 100Base‐TX Fast Ethernet  EMC Approvals  FCC Part 15 Class A, EN 55022 (CISPR 22) Class A, C‐Tick Class A  Safety Approvals  EN 60950, UL 1950, C‐Tick  Data Rate  100Mbps   Network Interface  16 x RJ45   Network Ports  16 auto‐speed sensing 10/100 Mbps UTP Ports, 8 with PoE   Status LED’s  Power and Ethernet Link/Activity indicators built into RJ45 Ports   Electrical Requirement  100‐240V AC 50/60Hz, Power Adapter 12V DC, 1A   Typical Power Consumption  5.5 Watts max  Enclosure   Desktop, indoor use only  Dimensions  287mm x 103mm x 27mm (WxDxH)   Weight  810 grams   Operating Temperature Range  C to +50 C   Operating Humidity  10‐90% RH, Non‐condensing      24 Port Ethernet Switch (24 PoE)   ...
  • Page 43: Specification: Repeater Psu

    28. SPECIFICATION: REPEATER PSU    Repeater Power Supply     Manufacturer/Model  Elmdene G13802N‐A  Tynetec Part No.  W00525   EMC Approval  2014/30/EU  LVD Approval  2014/35/EU  Environmental Approval  RoHS2: 2011/65/EC, WEEE: 2012/19/EU  Type  Switch Mode PSU with Electronic Overload Protection  Input Voltage  100V to 240V AC 50/60Hz  Output Voltage/Current  13.8V DC @ 2A   Output Ripple  150mV peak to peak  LED Indicators  Green = Mains Present and Red = Fault (Output/Battery Fuse Fail)  Mains Fuse Protection  T2.0A 20mm HRC  Load Fuse Protection  F2.0A 20mm Glass  Battery Protection  Re‐settable PTC  Enclosure Material  White powder coated 18 SWG steel with hinged lid   Ingress Protection Rating  IP41 (indoor sheltered)  Dimensions  200mm x 230mm x 80mm (HxWxD)   Weight  1.85 kilograms (excluding battery)  Operating Temperature Range  ‐10 C to +40...
  • Page 44: Specification: Uninterruptible Power Supply

    29. SPECIFICATION: UNINTERRUPTIBLE POWER SUPPLY    UPS    Manufacturer/Model No.  APC BE700G‐UK  Tynetec Part No.  ZXT548  EMC Approvals  EN 62040‐2, EN 55022, C‐Tick  Safety Approvals  IEC 62040‐1‐1, IEC 60884‐1  Input Voltage/Frequency  230V AC 50/60Hz  Input Connection  1.8 metres long with BS 1363 moulded non‐rewireable 13A UK Plug  Fuse Type/Rating  BS 1362 1” 240V AC 10A   Output Capacity (4 Outlets)  700VA 405 Watts (80 minutes @ 40W typical)  Output Voltage (on utility)  230V AC 47‐63Hz  Output Voltage (on battery)  230V AC +/‐ 8% 50Hz +/‐ 1Hz  8 x BS 1363 Sockets (4 with battery back‐up plus surge protection and   Output Connections  4 with surge protection only)   Battery Type  Maintenance‐free, sealed lead acid battery, leak proof  Battery Rating  12V 9Ah  Battery Life  3‐5 Years (depending on number of discharge cycles and temperature)  Enclosure   Black, free standing or wall mount, indoor use only  Status LED  Green = Power, Red = Fault  Audible Alarm  Yes (beep = on battery, rapid beep = low battery, constant = fault)  Dimensions ...
  • Page 45: Specification: Matrix Ip-Pbx

    30. SPECIFICATION: MATRIX IP‐PBX    Matrix IP‐PBX (8 IP Ports)    Manufacturer/Model No.  Matrix NE312‐EU  Tynetec Part No.  ZXT556  Resources    3 CO Ports  To connect Two Wires Trunk lines  8 IP Ports  To connect VoIP DECT Handsets (8 max)   12 SLT Ports  To connect Single Line Analogue Telephones  1 Ethernet Port  To connect VoIP users & trunks, web based programming & CDR reports  16 Voice Messages  For auto‐attendant & other voice based applications (14 seconds each)  Configuration  Local and remote programming via web based GUI  Power Supply    Input   External Adapter 24VDC @ 2A  Power Consumption  15 Watts  Mechanical    Enclosure  Desk or wall mount, optional 19” rack mounting brackets available  Dimensions  300mm x 42.5mm x 200mm (WxHxD)  Weight  1.22kg  Environment    Operating Temperature Range  ‐10 C to +50...
  • Page 46: Amendments Record

    31. AMENDMENTS RECORD    The table below lists significant changes to this manual;    Issue  Amendments  Date        1  Preliminary issue  16/08/18  2  First release  27/09/18                            Doc No. FM0814 issue 2 Page 46     ...