Download Print this page

Powers Hydroguard 410 5 Technical Instructions

Advertisement

Quick Links

DESCRIPTION
The Series 410 Hydroguard is a pressure compensating mixer
which delivers a predetermined water temperature, compen-
sating for pressure fluctuations in the hot or cold water supply.
The Series 410 Hydroguard features a poppet-type equaliz-
ing valve as part of a replaceable cartridge. The poppet-type
construction offers a distinct advantage, it will not stick
because of lime build-up or foreign particles in the supply.
The adjustable maximum temperature stop prevents acci-
dental scalding caused by overadjustment of the handle.
Many Series 410 valves and shower systems can be select-
ed to meet the Americans with Disabilities Act (ADA) [see
back page for details].
SPECIFICATIONS
Operating
Capacity: Shower and Tub
6 gpm at 45 psi differential [22.7 L/min at 310 kPa]
Maximum Static Pressure
. . . . . . . . . . . . . . . . . . .
Maximum Inlet Temperature
. . . . . . . . . . . . . . . . . . . . .
Inlet and Outlet Sizes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roughing-in Template
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum Temperature Adjustment
Complies to ASSE 1016 & CSA B125 .....................All Models
APPLICATION
The Series 410 Hydroguard is particularly recommended in
showers and shower bath installations for motels, hotels,
dormitories, and high rise apartment buildings.
OPERATION (SEE FIGURE 1)
Hot and cold water enter their respective ports and the pres-
sures are equalized through the action of the balance poppet
(1). The entire balancing poppet assembly is contained in a
Celcon chamber (2). This chamber is replaceable as a com-
plete cartridge. After the hot and cold pressures are equal-
ized, they are mixed by the action of a mixing plate (3). As
the temperature adjustment stem is rotated from shutoff to
maximum hot water temperature, the mixing plate passes
the required proportion of hot and cold water to produce the
control point. With the adjustment stem in its full clockwise
position, shutoff is obtained by closing both supplies.
The maximum temperature stop (4) allows the user to set the
maximum discharge temperature. This mixer does not recog-
nize supply water temperature changes, so any variation in
the water temperature will affect the control point and the
maximum temperature setting.
125 psi [862 kPa]
180°F [82°C]
1/2" NPT
All Models
All Models
. . . . . . . . . . . . . . . .
TECHNICAL INSTRUCTIONS
Hydroguard Series 410 Valves
411/416
FIGURE 1 – OPERATION
Cold Water Supply
Mixing Plate
Celcon Chamber
1
Balancing
Hot Water Supply
Poppet
Assembly
NOTE: Following any maintenance of unit, maximum
temperature stop must be reset. See page 5 for instruc-
tions.
Model 5 and Model 8
Form TI410-5 v3
3
4
Maximum
Temperature
Stop
Stem
Bonnet
2

Advertisement

loading

Summary of Contents for Powers Hydroguard 410 5

  • Page 1 TECHNICAL INSTRUCTIONS Hydroguard Series 410 Valves Model 5 and Model 8 Form TI410-5 v3 DESCRIPTION The Series 410 Hydroguard is a pressure compensating mixer which delivers a predetermined water temperature, compen- sating for pressure fluctuations in the hot or cold water supply. The Series 410 Hydroguard features a poppet-type equaliz- ing valve as part of a replaceable cartridge.
  • Page 2: Maintenance

    4. Flow of water continues when Hydroguard is shut off. a. Worn shut-off discs. Replace worn disc. FIGURE 3 – REVERSED INLETS b. Scratched mixing plate. c. Erosion. Contact a Powers applications engineer to Outlet order replacement parts. 5. Maximum temperature is too low.
  • Page 3 Page 3 PARTS See Nameplate to determine your valve model: COLD Model Date Number Code POWERS ABOVE: Parts 11-28 in Valve body BELOW: Parts 11-28 Detailed   21 21A † Used on 4-port mixers only. No discharge will occur when used in a 3-port mixer.
  • Page 4 TI410-5 v3 Page 4 PARTS – SERIES 410 HYDROGUARD Series 410 Hydroguard Pressure equalizing mixer. Poppet-type construction. Adjustable maximum temperature stop. Item Part Description Part No. Quantity Material 2a-2b Lever Handle Assembly (410 Model 8) see kit #410-448 Lever Handle Screw (8-32 x 1-1/4") C.P.
  • Page 5: Maximum Temperature Setting

    TI410-5 v3 Page 5 SERVICING FIGURE 4 – BALANCE CHAMBER REMOVAL 1. Shut off upstream water supply. 2. Remove the dial assembly and handle. See page 3 for rela- tionship of parts. Unscrew four cap screws and remove cap assembly by gently pulling on stem. 3.
  • Page 6: Troubleshooting

    1. Use silicone provided on all O-rings and related surfaces. Never use grease. 2. Some kits contain parts for all models; discard extra parts as appropriate. ADA-COMPLIANT OPTIONS When used together, Powers’ lever handle and handshower meet ADA compliance standards. For complete ADA- required heights and other information on installing an ADA- compliant bathing system, refer to the ADAAG (Americans 48"...
  • Page 7 TI410-5 V2 Page 7 NOTES...
  • Page 8 TI410-5 V2 Page 8 NOTES USA office: Phone: 800.669.5430 • Fax: 847.824.0627 www.powerscontrols.com Canadian office: Phone: 888.208.8927 • Fax: 888.882.1979 © 2003 Powers, a Watts Industries Co. A W a tts Industries Co. Form TI410-5 v3 0310 6511202 PRINTED IN U.S.A.

This manual is also suitable for:

Hydroguard 410 8Hydroguard 410 series