  • Page 1 PROFInet User Manual www.lsis.com...
  • Page 2 iS7 PROFInet Option Manual Safety Precaution First thank you for using our iS7 PROFInet Option Board! Please follow the following safety attentions since they are intended to prevent any possible accident and danger so that you can use this product safely and correctly. Safety attentions may classify into ‘Warning’...
  • Page 3 WARNING Do not remove the cover while power is applied or the unit is in operation. Otherwise, electric shock could occur. Do not run the inverter with the front cover removed. Otherwise, you may get an electric shock due to high voltage terminals or charged capacitor exposure.
  • Page 4: Table Of Contents

    iS7 PROFInet Option Manual Table of Contens About the Product ................... 4 Included Items ..................4 PROFInet Technical Features ..............4 GSDML File .................... 4 Part Names and Installation ................5 Exterior ....................5 Installing the PROFInet Communication Module ........5 PROFInet Communication Module Front Panel ........
  • Page 5: About The Product

    PROFInet Option Manual About the Product The LSIS iS7 PROFInet communication module (model CJ-S7M1) provides PROFInet network communication for the SV-iS7 inverter. PROFInet is a communication protocol compliant with IEC 61158 Type 10. The PROFInet communication module provides full-duplex data transfer which enables real-time communication without transmission collisions.
  • Page 6: Part Names And Installation

    iS7 PROFInet Option Manual Part Names and Installation 2.1 Exterior 2.2 Installing the PROFInet Communication Module Installation location...
  • Page 7: Profinet Communication Module Front Panel

    iS7 PROFInet Option Manual Remove the front cover. Connect the PROFInet communication module by inserting it into the connector on the inverter body. Secure the PROFInet communication module with the two mounting screws. Replace the cover. • Do not install or remove the PROFInet communication module while the power to the iS7 inverter is turned on.
  • Page 8 iS7 PROFInet Option Manual Indicator Color Description Status Remarks LINK1 is connected to a network. Normal Green LINK1 is not operation connected to a network Network LINK1 is not transmitting/receiving LED0 LINK1/ACT1 data Data transmission Normal Yellow between the Master operation unit and the Flashing...
  • Page 9: External Power Input

    iS7 PROFInet Option Manual Indicator Color Description Status Remarks indicators flash conditions exist asynchronously, between the in 2 second communication intervals module and the inverter. The communication module failed to boot Abnormal The CPU is not operation operating. LED3 CPU Green The communication Flashing...
  • Page 10 iS7 PROFInet Option Manual The 24 V external power input is a redundant power source to ensure uninterrupted operation of the communication module even when the main power source from the inverter is interrupted. The PROFInet communication module installed in an inverter (INV #1) keeps operating with this 24 V external power source if inverter (INV #1) malfunctions and cannot supply power to the module.
  • Page 11 iS7 PROFInet Option Manual...
  • Page 12: Network Connections

    iS7 PROFInet Option Manual Network Connections 3.1 Network Cable Contacts Pin No. Signal Description Cable Color Data Transmission (+) White/Yellow Data Transmission (-) Yellow Data Reception (+) White/Green NONE Not Used Blue NONE Not Used White/Blue Data Reception (-) Green NONE Not Used White/Brown...
  • Page 13: Profinet Communication Related Keypad Parameters

    iS7 PROFInet Option Manual PROFInet Communication Related Keypad Parameters To operate an iS7 inverter using the PROFInet communication module, set DRV-06 (Cmd Source) to [4 Fieldbus]. Set DRV-07 (Freq Ref Src) to [8 Fieldbus] to provide a frequency reference to the inverter using the PROFInet communication module. Code Parameter Name Default...
  • Page 14 iS7 PROFInet Option Manual IP – 3 12 opt para-3 13 opt para-4 IP - 4 14 opt para-5 Subnet Mask - 1 15 opt para-6 Subnet Mask - 2 Subnet Mask – 3 16 opt para-7 17 opt para-8 Subnet Mask - 4 18 opt para-9 Gateway - 1...
  • Page 15: Keypad Parameters Related To Profinet Communication Module

    iS7 PROFInet Option Manual Keypad Parameters Related to PROFInet Communication Module 5.1 CNF Group 5.1.1 [CNF-30] Option-1 Type: the type of device installed in the module slot 1 Automatically detects and displays the type of communication module installed. “PROFInet” is displayed when a PROFInet communication module is installed in the iS7 inverter.
  • Page 16: Com Group

    iS7 PROFInet Option Manual 5.3 COM Group 5.3.1 [COM-06] FBus S/W Ver: Communication Module Software Version Automatically detects and displays the software version of the currently installed communication module. 5.3.2 [COM-09] FBus LED: Communication Module Status Indicator (LED) Information Displays the communication module’s status indicator (LED) information on the inverter’s keypad.
  • Page 17 iS7 PROFInet Option Manual 5.3.3 [COM-10–21] IP Address, Subnet Mask, Gateway Settings The iS7 PROFInet communication module supports IPv4 protocol. All addresses and masks are expressed with four decimal numbers between 0 and 255, each separated by a dot (xxx.xxx.xxx.xxx). A PLC can forcibly reset the IP address by sending a DCP packet.
  • Page 18: Prt Group

    iS7 PROFInet Option Manual 5.4 PRT Group 5.4.1 [PRT-12] Lost Cmd Mode: Lost Command Mode Options Select the inverter’s operation mode for a “Lost Command” condition caused by a communication error. The following table lists available operation modes. Settings Description Speed reference becomes the operating frequency, without None a protective operation.
  • Page 19: Profidrive Status Diagram

    iS7 PROFInet Option Manual PROFIdrive Status Diagram The following diagram shows the operation status that the PROFInet communication module uses. Status Description The communication module cannot be switched ON at S1: Switching On Inhibited the moment. The communication module can be switched ON at any S2: Ready For Switching On moment.
  • Page 20 iS7 PROFInet Option Manual the PLC, and the command types are as follows. Refer to <7.2.1 Control word (STW1)> for more information. • NoQuickStop Command • NoCoastStop Command • SwitchOFF Command • SwitchON Command • OperationEnable Command • OperationDisable Command •...
  • Page 21: Supported Profidrive Cyclic Telegram

    iS7 PROFInet Option Manual Supported PROFIdrive Cyclic Telegram The iS7 communication module supports “Standard” and “Vendor Specific” telegrams. On a PROFInet network, it can exchange cyclic telegrams with a PLC, at a minimum cycle time of 8 ms. Each telegram is expressed as a submodule in PROFInet network communication, and can be assigned to either Slot1 or Subslot 2 at the communication module.
  • Page 22 iS7 PROFInet Option Manual Name Value Description Stops the motor using the setting at iS7 inverter OFF3 (Quick Stop) (ADV-8 “Stop Mode”). Operates the motor using the Setpoint value Enable Operation (frequency reference received from a PLC via the PROFInet network communication. Stops the motor using the setting at iS7 inverter Disable Operation (ADV-8 “Stop Mode”).
  • Page 23 iS7 PROFInet Option Manual The status transition explained in <10. PROFIdrive Operation Diagram> can be performed by setting the four control word bits, from bit 0 to bit 3. For example, setting the four bits to 1 (XXXX XXXX XXXX 1111) changes the status to “Operation.” Note “X”...
  • Page 24 iS7 PROFInet Option Manual 7.2.2 Status Word (ZSW1) Name Value Description Ready for Switch ON (Operation is available.) RDY_ON Not Ready for Switch OFF (Operation is not available.) Bit 0 value of the control word (STW1) RDY_OPERATION that has been input. Bit 3 value of the control word (STW1) OPERATION that has been input.
  • Page 25 iS7 PROFInet Option Manual “bits 0 to 2” and “bit 6” indicate the following communication module status, as explained in <10. PROFIdrive Status Diagram>. Status Word Status “Switching On Inhibited” xxxx xxxx x1xx x000 “Ready For Switching On” xxxx xxxx x0xx x001 “Ready For Operation”...
  • Page 26 iS7 PROFInet Option Manual Name Description compatible parameter communication addresses. This bit is set to 1 when more than one bit in the “level type trip information” parameter bit field is set to 1. Bit for displaying “level type trip Otherwise, it is set to 0.
  • Page 27: Supported Profidrive Parameters

    An array of five 16-bit word values that expresses the iS7 communication module information. 0: Manufacturer (the PROFInet vendor ID “849” for LSIS, as defined by the Profibus.org, is displayed (referenced from communication address 0h351). 1. Device Type: “1” is displayed for iS7 PROFInet communication module.
  • Page 28 iS7 PROFInet Option Manual Description Displays the control word (STW1) value that is currently input via the PROFInet communication network. Displays the status word (ZSW1) value that is currently input via the PROFInet communication network. The iS7 communication module is reset when the parameter value is changed to “1”...
  • Page 29: Fault Message Counter (Pnu[944]) And Fault Number (Pnu[947])

    iS7 PROFInet Option Manual Fault Message Counter (PNU[944]) and Fault Number (PNU[947]) The Fault Message Counter (PNU[944]) parameter value increases by 1 each time an inverter fault occurs, and the fault is saved at the Fault Number (PNU[947]) parameter. The Fault Number (PNU[947]) parameter can save 8 Fault Situations, and each Fault Situation contains 8 Fault Messages.
  • Page 30 iS7 PROFInet Option Manual following table. Trip Names Fault Message Overload Trip Underload Trip Inverter Overload Trip E-Thermal Trip Ground Fault Trip Missing Output Phase Trip Missing Input Phase Trip Overspeed Overspeed Deviation NTC Trip Overcurrent Trip Overvoltage Trip External Trip Arm Short Overheat Trip Fuse Open Trip...
  • Page 31 iS7 PROFInet Option Manual Trip Names Fault Message Inverter Output Cutoff by Optional Safety Device Terminal Input (For 90 kW and higher inverter models) Reserved Reserved Lost Command Keypad Lost Command Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved...
  • Page 32 iS7 PROFInet Option Manual Trip Names Fault Message Reserved Reserved Reserved Reserved Reserved Internal Communication Error between the Inverter and the Option Card...
  • Page 33: Accessing The Is7 Common Parameters Using The Profidrive Parameters

    iS7 PROFInet Option Manual Accessing the iS7 Common Parameters using the PROFIdrive Parameters Using the PROFIdrive parameters (PNU [1000–1003]), you can access the iS7 inverter parameters for data reading and writing. The following diagram explains the parameter writing procedure. Inverter communication address is assigned to PNU [1000]. Inverter setting data is assigned to PNU [1001].
  • Page 34 iS7 PROFInet Option Manual The following diagram explains the parameter reading procedure. Inverter communication address is assigned to PNU [1000]. PNU [1003] is set to 0. When PNU [1002] is set to 2, the iS7 PROFInet communication module references PNU [1000] and reads the data saved in the inverter’s internal address pointed by it.
  • Page 35: Accessing Is7 Inverter Parameters Using The Profinet Record Data Object

    iS7 PROFInet Option Manual Accessing iS7 Inverter Parameters using the PROFInet Record Data Object Using the PROFInet Record Data object, you can access the iS7 inverter parameters for data reading and writing, without the PROFIdrive communication protocol. The inverter’s parameter data is assigned to the PROFInet Record Data from the index address 0h5000.
  • Page 36: Processing The Alarms

    iS7 PROFInet Option Manual Processing the Alarms The iS7 communication module sends a PROFInet alarm notification to the PLC when a fault trip occurs, or when it is released. Fault Alarm Packet Details User Channel Slot Subslot Alarm Channel Type Structure Error Number...
  • Page 37: Trouble Shooting

    LSIS customer support. ERROR indicator is The hardware is malfunctioning. Contact a service agent turned on, and CPU near you or LSIS customer support. indicator is turned off. • Check the connector pins on the communication module ERROR indicator and for bends or other defects.
  • Page 38 iS7 PROFInet Option Manual Installation Maker LS Industrial Systems Co., Ltd. (Start-up) Date Model No. SV-iS7 PROFInet Option Board Warranty Period Name Customer Address Information Tel. Name Sales Office Address (Distributor) Tel. Warranty period is 12 months after installation or 18 months after manufactured when the installation date is unidentified.
  • Page 39 iS7 PROFInet Option Manual 제품을 사용하기 전에 먼저 저희 iS7 PROFInet 옵션 보드를 사용하여 주셔서 감사합니다. 안전상의 주의사항  안전상의 주의사항은 사고나 위험을 사전에 예방하여 제품을 안전하고 올바르게 사용하기 위한 것 이므로 반드시 지켜주십시오.  주의사항은 ‘경고’와 ‘주의’의 두 가지로 구분되어 있으며 ‘경고’와 ‘주의’의 의미는 다음과 같습니다. 지시사항을...
  • Page 40 iS7 PROFInet Option Manual 목 차 소개 ........................................4 PROFInet Technical Features ..............................4 제품 구성물 ....................................4 iS7 PROFInet 통신 옵션 형명 ............................... 5 PROFInet 통신 옵션 외관 및 설치 ............................ 5 외관 ......................................5 iS7 PROFInet 통신 옵션 설치 ............................5 PROFInet 통신...
  • Page 41 iS7 PROFInet Option Manual CNF 그룹 ....................................13 DRV 그룹 ....................................13 COM 그룹 ..................................... 13 PRT 그룹 ....................................15 PROFIdrive 상태도 ................................16 지원 PROFIdrive Cyclic Telegram ..........................19 Standard Telegram (Mode : 0) ............................ 19 Vender Specific Telegram (Mode : 1) ........................19 지원...
  • Page 42: 소개

    iS7 PROFInet Option Manual 1. 소개 PROFInet 통신 옵션 카드는 SV-iS7 인버터를 산업통신망 국제규격인 IEC 61158의 Type 10에 해당하는 PROFInet 네트워크에 연결되도록 합니다. Full-duplex 방식을 이용하여 충돌 없는 통신으로 통신상의 실시간성을 확보하며, iS7 인버터의 제어 및 모니터링이 PLC의 시퀀스 프로그램 또는 임의의 Master Module에 의해 제어가 가능해집니다. 배선이...
  • Page 43: Is7 Profinet 통신 옵션 형명

    iS7 PROFInet Option Manual 4. iS7 PROFInet 통신 옵션 형명 형명: CJ-S7M1 5. PROFInet 통신 옵션 외관 및 설치 외관 iS7 PROFInet 통신 옵션 설치...
  • Page 44: Profinet 통신 옵션 Led 표시 부

    iS7 PROFInet Option Manual ① iS7 인버터 본체의 Cover를 분리합니다. ② iS7 통신옵션 접속 부에 PROFInet 통신 옵션을 체결한 후, 나사 체결(2개)을 해주십시오. ③ iS7 인버터와 PROFInet 통신 옵션이 체결되었습니다. iS7 인버터의 전원이 켜진 상태에서 PROFInet 통신 옵션 장치를 장착하거나 혹은 제거 하지 마십시오.
  • Page 45 iS7 PROFInet Option Manual LED 명칭 Color 동작 의미 동작 의미 Network Link 1이 연결 되었음 Green 정상 동작 Network Link 1이 연결 되어 있지 않음 LED0 LINK1/ACT1 Network Link1에서 데이터 송/수신 없음 Yellow 정상 동작 Network Link1에서 통신 마스터와 데이터 송/ 점멸...
  • Page 46: 외부 24V 전원 입력 부

    iS7 PROFInet Option Manual 외부 24V 전원 입력 부 Pin No. 이름 설명 +24V 외부 24V 전원 (+) 외부 24V 전원 (-) 외부 24V 전원에 대한 Protective Earth * 그림 상단부터 1번 pin * 전원 용량 (소비전력) : 1.3W 외부 24V 전원 입력 부는 인버터 인버터 본체로부터 입력 받은 주 전원이 차단 되어도, 계속해서 iS7 PROFInet 통신...
  • Page 47 iS7 PROFInet Option Manual...
  • Page 48: Network 연결

    iS7 PROFInet Option Manual 외부 24V 전원이 공급되는 상태에서 인버터 본체 전원이 차단될 경우, iS7 PROFInet 통신 모듈은 “Fault 발생 Alarm”를 PLC에 전송합니다. Alarm 수신 후 PLC 측에서 “H/W Diagnosis Trip 정보(통신 주소: 0h0333)”의 최상위 Bit가 1로 설정된 것을 확인할 수 있습니다. 주의...
  • Page 49: Network 케이블 규격

    iS7 PROFInet Option Manual 7. Network 케이블 규격 PROFInet 통신 옵션을 사용하기 위해서는 STP(일반적으로 카테고리 6a 이상)의 케이블을 사용 합니다. 8. PROFInet 통신 옵션과 관련 Keypad 파라미터 PROFInet 통신 옵션을 사용하여 iS7 인버터를 운전 시키고 싶은 경우에는 Keypad의 DRV-06 Cmd Source를...
  • Page 50 iS7 PROFInet Option Manual 12 opt para-3 IP – 3 13 opt para-4 IP - 4 14 opt para-5 Subnet Mask - 1 15 opt para-6 Subnet Mask - 2 16 opt para-7 Subnet Mask – 3 17 opt para-8 Subnet Mask - 4 18 opt para-9 Gateway - 1...
  • Page 51: Profinet 통신 옵션과 관련 Keypad 파라미터 설명

    iS7 PROFInet Option Manual 9. PROFInet 통신 옵션과 관련 Keypad 파라미터 설명 CNF 그룹 ① [CNF-30] Option-1 Type: 옵션 슬롯1의 종류 표시 현재 iS7에 장착된 통신 카드 종류를 자동으로 나타냅니다. iS7 PROFInet 통신 옵션 카드를 iS7 인버터에 장착 시 자동으로 “Profinet”으로 표시 됩니다. DRV 그룹...
  • Page 52 iS7 PROFInet Option Manual [COM-09] FBus LED 표시의 예) 09 FBus LED LED 명 LINK1/ACT1 LINK2/ACT2 LED 상태 ③ [COM-10~21] IP Address, Subnet Mask, Gateway 설정 PROFInet 통신 모듈이 지원하는 IP의 버전은 v4를 선택하고 있습니다. 즉 모든 주소나 마스크들은 10진수.10진수.10진수.10진수로 표현이 되어 있으며, 각각의 10진수는 0~255 사이의...
  • Page 53: Prt 그룹

    iS7 PROFInet Option Manual (4) PRT 그룹 ① [PRT-12] Lost Cmd Mode: 통신 지령 상실 시 감속 동작 모드 통신 지령 상실이 발생하였을 때 인버터의 동작 모드를 선택합니다. 동작 모드는 아래 표와 같습니다. 설정 값 설 명 None 보호 동작 없이 속도 지령이 그대로 운전 주파수가 됩니다. Free-Run 인버터가...
  • Page 54: Profidrive 상태도

    iS7 PROFInet Option Manual 10. PROFIdrive 상태도 아래 그림은 PROFInet 통신 모듈에서 사용하는 상태도 입니다. 상태 설명 S1: Switching On Inhibited 현재 통신 모듈 상태가 Switch On 할 수 없는 상태 입니다. S2: Ready For Switching On 언제라도 Switch on으로 변경 할 수 있는 상태 입니다. S3: Ready For Operation 언제라도...
  • Page 55 iS7 PROFInet Option Manual 각 상태의 천이는 PLC에서 주기적으로 내려 오는 명령에 의해 발생 합니다. 명령의 종류는 아래와 같으며 자세한 내용은 “11. 지원 PROFIdrive Cyclic Telegram” 항의 Control word 항에서 설명 합니 다. ① NoQuickStop 명령 ② NoCoastStop 명령 ③ SwitchOFF 명령 ④...
  • Page 56 iS7 PROFInet Option Manual 각 상태의 천이의 이벤트와 동작은 아래 표와 같습니다. Source State Target State Event Action “Switch On Inhibited” “Ready For Switching "SwitchOFF" 없음(모터 정지 상태) On” "NoQuickStop" "NoCoastStop" “Ready For Switching “Switch On Inhibited” "QuickStop" 없음(모터 정지 상태) On”...
  • Page 57: 지원 Profidrive Cyclic Telegram

    iS7 PROFInet Option Manual 11. 지원 PROFIdrive Cyclic Telegram 지원 하는 Cyclic Telegram 종류는”Standard Telegram” 과 “Vender Specific Telegram”입니다. iS7 PROFInet Option 통신 모듈은 최소 8ms 주기로 Cyclic Telegram를 PLC와 교환할 수 있습니다. 각 Telegram은 PROFInet 통신에서 Submodule로 표현 되며, PROFInet 네트워크 Configuration Tool에 서...
  • Page 58 iS7 PROFInet Option Manual No OFF2 OFF2(Coast Stop) 기능이 설정되지 않은 상태입니다. 현 운전상태를 유지합니다. OFF2 (Coast Stop) 모터를 Free Run Stop(비상정지)으로 멈춥니다. No OFF3 OFF3(Quick Stop) 기능이 설정되지 않은 상태입니다. 현 운전상태를 유지합니다. OFF3(Quick Stop) iS7 인버터 파라미터 ADV-8 Stop Mode 에 설정된 방법으로...
  • Page 59 iS7 PROFInet Option Manual Control By PLC PROFInet 통신을 통해 PLC로부터 받은 Control word(STW1)를 통해 iS7 인버터를 제어합니다. No Control By PLC PROFInet 통신을 통해 PLC로부터 받은 Control word(STW1)를 무시 합니다. 11 ~ 15 Reserved Bit 0~3의 값으로 Control Word 값을 변경해서, “10 장 PROFIdrive 상태도”에 표시한 상태 변화를 발생...
  • Page 60 iS7 PROFInet Option Manual 예)모터구동 시 Bit설정 Bit 종 Bit10 Bit9 Bit8 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 -주2) -주2) 설정값 주2) ’-‘는 설정 유무와 상관없이 모터구동이 가능합니다.
  • Page 61 iS7 PROFInet Option Manual ② Status word(ZSW1) Name Value Description RDY_ON Ready To Switch ON (동작 가능 상태) Not Ready To Switch OFF (동작 불가능 상태) RDY_OPERATION 현재 입력 받은 Control word(STW1)의 0번 비트 값을 나타냅니다. OPERATION 현재 입력 받은 Control word(STW1)의 3번 비트...
  • Page 62 iS7 PROFInet Option Manual “10. PROFIdrive 상태도”에서 나타낸 상태에 따라, Bit 0~2과 Bit 6은 통신 모듈의 상태 값을 아래 표와 같이 나타냅니다. Status Word 상태 xxxx xxxx x1xx x000 “Switching On Inhibited” xxxx xxxx x0xx x001 “Ready For Switching On” xxxx xxxx x0xx x011 “Ready For Operation”...
  • Page 63 iS7 PROFInet Option Manual “레벨 타입 트립 정보” 인버터 “레벨 타입 트립 정보” 파라미터의 각 비 표시 비트 트 필드 중 하나 이상 1로 되었을 경우 1로 표시, 그 이외는 0으로 표시됨 인버터 호환 공통영역 파라미터 통신 주소 0h0332 번 참조 “H/W Diagnosis Trip 정보”...
  • Page 64: 지원 Profidrive 파라미터

    iS7 PROFInet Option Manual 12. 지원 PROFIdrive 파라미터 Parameters 설명 선택된 PROFIdrive Cyclic Telegram 종류를 표시 합니다. 1번 → Standard Telegram 100번 → Vender Specific Telegram *PROFIdrive 프로토콜을 통한 쓰기는 지원하지 않으며, 인버터 키패드를 통해서 설정 가능합니다. COM 그룹의 22번 opt para-13이...
  • Page 65 iS7 PROFInet Option Manual 3: Firmware Date(yyyy): S/W가 만들어진 년도를 표시합니다. 예) 2015년이면, 2015로 표시됩니다. 4: Firmware Data(dd/mm) : S/W가 만들어진 날짜/월을 나타냅 니다.. 예) 12월 25일 이면, 2512로 표시됩니다. Profile ID를 표시하는 파라미터입니다. (0h328 – Profile 3 v4.0) 현재 PROFInet를 통해 입력 받는 Control word(STW1) 값을 표 시...
  • Page 66 iS7 PROFInet Option Manual 2: Not OK completed...
  • Page 67: Pnu[944] Fault Message Counter와 Pnu[947] Fault Number 설명

    iS7 PROFInet Option Manual 13. PNU[944] Fault Message Counter와 PNU[947] Fault Number 설명 인버터에서 Fault가 발생할 때마다, PNU[944] Fault Message Counter 값은 1씩 증가하고, 해당 Fault 는 PNU[947] Fault Number 변수에 저장 됩니다. PNU[947] Fault Number는 8개의 Fault Situation를 저장할 수 있고, 각 Fault Situation은 총 8개의 Fault Message를...
  • Page 68 iS7 PROFInet Option Manual Underload Trip Inverter Overload Trip E-Thermal Trip Ground Fault Trip 출력 결상 트립 입력 결상 트립 Overspeed Overspeed Deviation NTC Trip Overcurrent Trip Overvoltage Trip External Trip Arm Short Overheat Trip Fuse Open Trip MC Fail Trip Encoder Error Trip PTC(Thermal 센서) Trip FAN Trip...
  • Page 69 iS7 PROFInet Option Manual Slot3 옵션 카드 접촉 불량 Safety Option 상의 단자대 입력에 의한 인버터 출력 차단 (90kW 이상 제품만 해당됨.) Reserved Reserved Lost Command 키패드 Lost Command Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved ADC 에러...
  • Page 70 iS7 PROFInet Option Manual Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved 인버터 옵션 본체간 내부 통신 Error...
  • Page 71: Profidrive 파라미터를 이용한 Is7 공통 파라미터 접근 절차

    iS7 PROFInet Option Manual 14. PROFIdrive 파라미터를 이용한 iS7 공통 파라미터 접근 절차 사용자는 PNU [1000 ~ 1003] 파라미터를 이용하여, iS7 인버터 본체의 파라미터를 읽고 쓸 수 있습 니다. 아래는 인버터 파라미터 쓰기 요청의 순서도입니다. ① PNU [1000] 파라미터에 인버터 통신 주소 값을 설정합니다. ②...
  • Page 72 iS7 PROFInet Option Manual ④ PNU [1002] 파라미터에 1을 설정하면 iS7 PROFInet 통신 모듈이 PNU [1000], PNU [1001] 값 을 참조하여 인버터 본체 파라미터에 저장합니다. ⑤ iS7 PROFInet 통신 모듈은 인버터 파라미터 값을 저장하고 동작 결과를 PNU [1003]에 저장 합니다. ⑥...
  • Page 73 iS7 PROFInet Option Manual ① PNU [1000] 파라미터에 인버터 통신 주소 값을 설정합니다. ② PNU [1003] 파라미터에 0를 설정합니다. ③ PNU [1002] 파라미터에 2를 설정하면 iS7 PROFInet 통신 모듈이 PNU [1000] 값을 참조하여 PNU [1000]의 값이 가리키는 인버터 본체 값을 읽어옵니다. ④...
  • Page 74 iS7 PROFInet Option Manual...
  • Page 75: Profinet Record Data Object를 이용한 Is7 Parameter Access

    (래치 타입 트립-1/2, 레벨 타입 트립, H/W Diagnosis Trip 정보)의 값을 읽어야 합니다. 17. GSDML 파일 인버터 PROFInet 통신 모듈에 대한 정보가 들어 있는 파일입니다. PROFInet 네트워크 설정 소프트웨 어에서 이 파일을 필요로 합니다. ** 당사 홈페이지 http://www.lsis.co.kr/ 에 접속하여 다운로드 받으실 수 있습니다. 18. 이상 대책 및 점검 (Trouble Shooting)
  • Page 76 iS7 PROFInet Option Manual 순서 현상 이상 대책 ERROR LED와 CPU LED가 모두 통신 모듈에 전원이 정상적으로 공급되지 않은 경우 발생할 소등되는 경우 수 있는 현상입니다. 1) 통신 모듈을 인버터 본체에 바르게 장착하여 주십시오. 2) 본체와 연결되는 통신 모듈의 커넥터의 핀이 파손 또는 휘어지지...
  • Page 77 iS7 PROFInet Option Manual 품 질 보 증 서 제품명 LS산전 통신옵션카드 설치 일자 모델명 SV-iS7 PROFInet 통신 카드 보증 기간 성 명 고 객 주 소 전 화 성 명 판매점 주 소 전 화 알아두기 본 제품은 LS 산전 기술진의 엄격한 품질관리 및 검사과정을 거쳐서 만들어진 제품입니다. 제품...