INVERTER SETTING
Pr. 338 "operation control
Control
command source"
location
Pr. 339 "speed command
selection
Load pattern selection-forward/
17
reverse rotation boost switching
(X17)
18 Magnetic flux-V/F switching (X18)
Load torque high-speed frequency
19
(X19)
S-pattern acceleration/
20
deceleration C selection terminal
(X20) *3
22 Orientation command (X22) *3
23 Pre-excitation (LX) *3
Remote setting (RH, RM, RL)
RH, RM,
Programmed operation group
RL, RT
selection (RH, RM, RL) *4
selective
functions
Stop-on-contact selection 0 (RL) *4
Stop-on-contact selection 1 (RT) *4
External
: Control by signal from external terminal is only valid.
NET
: Control from Profibus master module is only valid.
Combined
: Control from both external terminal and Profibus master module
is valid.
: Control from both external terminal and Profibus master module
is invalid.
Compensation : Control by signal from external terminal is only valid if Pr. 28
"multi-speed input compensation" setting is "1".
*1 If the FR-HC connection, FR-CV connection (inverter operation enable signal)
(X10) is not assigned when "2" is set in Pr. 30 "regenerative function selection"
(when the FR-HC or FR-CV is used) or if the PU operation interlock signal
(X12) is not assigned when "7" (when the PU operation interlock function is set)
is set in Pr.79 "operation mode selection" , this function is also used by the
MRS terminal and therefore operation is only valid for the external terminal,
independently of Pr. 338 and Pr. 339 settings.
*2 When the MRS signal is assigned to both network and external control, the
output stop command is as listed below:
Network
External
ON
ON
OFF
OFF
*3 This setting is valid only when the FR-A5AP option is mounted. (The FR-A5AP
cannot be used with the FR-F500 series.)
*4 Programmed operation is available only with the FR-A500 series.
source"
Pr. 17 = 0
ON
Output stopped
OFF
Output stopped
ON
Output stopped
OFF
Output not stopped
0: NET
0: NET
1: External 1: External
0: NET
1: External
0: NET
NET
NET
External External
NET
NET
External External
NET
NET
External External
NET
NET
External External
NET
NET
External External
NET
NET
External External
NET
External
NET
NET
External
NET
NET
NET
External External
Output Stop Command
16
REMARKS
1: External
External Pr. 59 = 1, 2
Pr. 79 = 5
Network
operation is
disabled
External Pr. 270 = 1,
3
Pr. 17 = 2
Output not stopped
Output stopped
Output stopped
Output stopped