BWT AQUADIAL softlife 10 Fitting And Operating Instructions

BWT AQUADIAL softlife 10 Fitting And Operating Instructions

Domestic water softener

Advertisement

Important notice: Always keep the fitting and operating instructions close
at hand to avoid any mistakes and before carrying out any work on the
device you should read the fitting and operating instructions carefully and
follow them. While our data sheets and brochures should provide advice
to the best of our knowledge, the content thereof is not legally binding.
deliquatinim acin henis at.
Wichtige Hinweise: Um Fehler zu vermeiden, ist die Einbau- und Bedie-
nungsanleitung stets griffbereit aufzubewahren, vor der Ausführung von
Arbeiten am Gerät vollständig durchzulesen und zu beachten. Unsere
Merkblätter und Druckschriften sollen nach bestem Wissen beraten, der
Inhalt ist jedoch ohne Rechtsverbindlichkeit. Im Übrigen gelten unsere
allgemeinen Geschäftsbedingungen.
Fitting and operating instructions
Einbau- und Bedienungsanleitung
BWT AQUADIAL
softlife
Domestic water softener
10, 15, 20, 25
Weichwasseranlage
10, 15, 20, 25
EN
D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQUADIAL softlife 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for BWT AQUADIAL softlife 10

  • Page 1 Fitting and operating instructions Einbau- und Bedienungsanleitung BWT AQUADIAL softlife Domestic water softener 10, 15, 20, 25 Weichwasseranlage 10, 15, 20, 25 Important notice: Always keep the fitting and operating instructions close at hand to avoid any mistakes and before carrying out any work on the device you should read the fitting and operating instructions carefully and follow them.
  • Page 2: Table Of Contents

    6.1 Trouble shooting Guide ....................... 17 7. Technical data ..........................19 7.1 BWT AQUADIAL softlife 10 / 10 Bio* ................. 19 7.2 BWT AQUADIAL softlife 15 / 15 Bio* ................. 20 7.3 BWT AQUADIAL softlife 20 / 20 Bio* ................. 21...
  • Page 3: Introduction

    Models covered by this manual: The complete power supply unit must be replaced BWT AQUADIAL for the device types: in the event of damage to the mains cable. softlife 10 / 10 Bio Warning: softlife 15 / 15 Bio...
  • Page 4: Scope Of Delivery

    1.5 Scope of delivery BWT AQUADIAL softlife water softer with: Standard delivery: 1. Multi-way control valve with microprocessor controller 2. Blending valve 3. Softening column with ion exchange resin 4. Softened water outlet 5. Hard water inlet 6. Drain water 7.
  • Page 5: Quick Operation

    2.2 Standard factory settings Operating range: depends on model Regeneration time: free input at RECHARGE TONIGHT Hardness of drinking water / capacity: 300 ppm, 1566 litres for 10 litre model BWT AQUADIAL softlife Standard Display Operating range UK/EU UK/EU 1.7 ... 5.0 bar 1.0 ...
  • Page 6: Programming Procedure

    2.3 Programming procedure 2. Setting the water hardness (see Fig. 2) The display default is 300 ppm (typical hardness le- vel) which indicates a setting suitable for hard water with a value of 300 parts per million of hardness minerals. Use the keys [UP] [DOWN] keys to adjust the setting to match that of the one you obtained / identified earlier.
  • Page 7: Installation

    3. Installation Inlet- and outlet connections: When installing the unit, select a location where the 3.1 Installation requirements unit can easily be connected to the water supply net- work. A connection to the waste water system (at National guidelines and regulations: least DN 50), a floor drain and a separate mains Observe all applicable installation regulations, ge- socket (see technical data) must be nearby.
  • Page 8: Installation And Operation Considerations

    Handing over the unit to the operator: 3.3 Installation and operation considerations If there is a delay between the installation/startup 1. Before you begin of the unit and transfer to the operator, a manual regeneration must be performed. The operator must The installation of your new water softener is rela- be told how the unit works as well as how to operate tively straightforward.
  • Page 9 3. Loft installation 5. Backflow prevention device The water softener should be installed within a con- When fitted to the supply feeding a single dwelling, tainer of not less than 100 litre capacity, to which a check valve complying with national regulations there should be connected an overflow pipe of not must be fitted on the cold water feed prior to the less than 20 mm diameter.
  • Page 10: Installation Layout

    3.4 Installation Layout To rising Inlet from main mains Outlet from Inlet to softener softener Key to the diagram: H. Fixing clip Key to the diagram: A. Non return valve I. Waste water hose B. Pressure reducing valve (where required) J.
  • Page 11: Technical Overview Of Device

    3.5 Technical overview of device: C. Inlet connection (feed water)  for flexible hose, with thread ¾“ Outlet connection (softened water)  for flexible hose, with thread ¾“ G1. Brine storage cabinet  salt filling G2. Connection to brine  internal connection ...
  • Page 12: Installing Your Softener

    3.6 Installing your softener If the water softener is fitted in a cellar or basement, the overflow can be run to a storage tank. Do not 1. Positioning the water softener elevate the overflow hose. Note: Do not use jointing cement on the fitting. It is very important to establish the water pressure before installing the water softener.
  • Page 13: Operation

    4. Operation Shake the bottle in between and keep adding tablets to the water until the solution turns from 4.1 Function wine red to blue, record the number of tablets as you go. Capacity requirement-dependent of the unit Using the data table supplied with your kit, controller: match up the number of tablets with the hard- ness.
  • Page 14 Charge Bar Adding regenerative Refill the salt no later than when SALt is indicated Having set the display on the control facia, you will notice that during normal operation there is a char- on the display or 150mm above the base of the ge bar running along the bottom of the display.
  • Page 15: Setting The Hardness Of Blended Water

    2x annually and the hardness of the blen- At the end of product life ded water must be corrected when required (see please contact BWT Customer Start-up). Services to arrange a new replacement for your softener.
  • Page 16: Fault Finding

    6. Fault finding 6.1 Trouble shooting Guide Attention: If your water softener is not performing as it should, please run through the check list below. Checklist Solution Page Problem: Water still remains hard. Is there a minimum of 150mm of salt in Fill the brine cabinet with salt.
  • Page 17 Attention: If your water softener is not performing as it should, please run through the check list below. Checklist Solution Page Problem: Water runs from the drain constantly. Is the unit in recharge mode? If yes, this is normal, wait until the recharge is complete.
  • Page 18: Technical Data

    7. Technical data 7.1 BWT AQUADIAL softlife 10 / 10 Bio* BWT AQUADIAL softlife Type 10 / 10 Bio Nominal connection (outside thread) ¾“ (DN 20) Nominal flow rate in accordance with EN 14743 1440 Nominal pressure (PN) Operating pressure EU (min./max.) 1.0 / 8.0...
  • Page 19: Bwt Aquadial Softlife 15 / 15 Bio

    7.2 BWT AQUADIAL softlife 15 / 15 Bio* BWT AQUADIAL softlife Type 15 / 15 Bio Nominal connection (outside thread) ¾“ (DN 20) Nominal flow rate in accordance with EN 14743 1560 Nominal pressure (PN) Operating pressure EU (min./max.) 1.0 / 8.0 Operating pressure UK (min./max.)
  • Page 20: Bwt Aquadial Softlife 20 / 20 Bio

    7.3 BWT AQUADIAL softlife 20 / 20 Bio* BWT AQUADIAL softlife Type 20 / 20 Bio Nominal connection (outside thread) ¾“ (DN 20) Nominal flow rate in accordance with EN 14743 1680 Nominal pressure (PN) Operating pressure EU (min./max.) 1.0 / 8.0 Operating pressure UK (min./max.)
  • Page 21: Bwt Aquadial Softlife 25 / 25 Bio

    7.4 BWT AQUADIAL softlife 25 / 25 Bio* BWT AQUADIAL softlife Type 25 / 25 Bio Nominal connection (outside thread) ¾“ (DN 20) Nominal flow rate in accordance with EN 14743 1680 Nominal pressure (PN) Operating pressure EU (min./max.) 1.0 / 8.0 Operating pressure UK (min./max.)
  • Page 22 Guideline for electromagnetic compatibility (EMC) Note: Do not perform any changes, extension and reconstruction work on the device which might impair safety without the approval of BWT UK Ltd., otherwise this decla- ration loses its validity. Note: Please ensure that all conditions of the...

Table of Contents