Easy Start Guide
Parker AC10 Series Inverter (to 22kW)
14. How to reset the Inverter to Factory Defaults
This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright
Drive Supermarket and must not be reproduced or altered without prior written permission.
14.1 Select parameter list.
With the motor stopped, press the "M" key repeatedly until the
parameter list is shown.
The parameter list is prefixed with "F" as illustrated (left).
14.2 Select parameter "group" 1.
Press the "0" (stop) key to select the first (left) digit. This represents
the parameter group (F100, F200, F800 etc.)
Use the up and down keys to select parameter group F100.
Note: In parameter "group" mode, the "DGT" (digit) lamp is not
illuminated.
14.3 Select parameter F160.
Press the "0" (stop) key to select the last two (right) digits. This
represents the parameters within the group.
Use the up and down keys to select parameter F160. Press the "E"
key to edit the parameter value.
Note: In parameter mode, the "DGT" (digit) lamp is illuminated.
14.4 Set the value to 1 and save.
The initial value of 0 flashes. Use the up and down keys to change
this to 1.
Press the "E" key to save the new value. The display will stop
flashing and may briefly go blank.
Once the reset is complete the display will return to the parameter
list. The factory reset is complete.
©