MAKING MODERN LIVING POSSIBLE Technical Information Proportional Valve Group PVG 100 powersolutions.danfoss.com...
Page 2
PVG 100 Proportional Valve Group Revision History Table of Revisions Date Changed Jan 2014 Converted to Danfoss layout – DITA CMS Feb 2006 - Aug 2013 Various changes BA - EA Feb 2005 New Edition 520L0720 • Rev EB • Jan 2014...
Remote control units ................................9 PVG 100 function PVG 100 with open center PVPF...............................10 PVG 100 with closed center PVPV / PVPVP / PVPVM......................12 PVG 100 closed center priority steering PVPVP module ................... 12 PVG 100 closed center PVPVM module ........................... 12 PVG 100 basic modules PVB...............................12...
Page 4
PVG 100 Proportional Valve Group Contents PVG 100 with variable displacement pump schematic example................. 33 Electrically actuated PVG 100, variable displacement pump, PVB 100 with integrated pilot operated check valves..................................... 34 Electrically actuated PVG 100/32, fixed displ. pump, PVB 100/32 with integrated pilot operated check valves.....................................
Page 5
PVG 100 dimensions in general..............................52 PVG 100 with open center PVPF ..............................53 PVG 100/32, closed center PVPV.............................. 55 PVG 100, Closed Center PVP with Integrated Priority Valve ..................57 Example: PVG 100 with variable displ. pump........................59 Module selection chart Exploded view for module selection .............................
Technical Information PVG 100 Proportional Valve Group General Information Acronyms This table provides a definition of some commonly used terms PVG = Proportional Valve Group Pump Side Module (Inlet) PVMD Cover for Mechanical Activation PVPF Open Center PVP PVMF Cover for Mechanical Float...
From a simple load sensing directional valve to an advanced electro hydraulic controlled load independent proportional valve the PVG 100 modular system makes it possible to build up a valve group to fulfill customer requirements. The compact external dimensions of the valve remain unchanged whatever combination is specified.
Technical Information PVG 100 Proportional Valve Group General Information Remote control units • Electrical remote control units: ‒ ‒ PVRE, PVRET JS1000 Ball grip ‒ ‒ PVREL JS1000 PRO grip ‒ ‒ PVRES JS2000 ‒ ‒ Prof 1 JS6000 ‒...
PVG 100 Proportional Valve Group PVG 100 function PVG 100 with open center PVPF When the pump is started and the main spools in the individual basic modules are in the neutral position, oil flows from the pump, through connection P, across the pressure matching spool (11) to tank. The oil flow led across the pressure matching spool determines the pump pressure (stand-by pressure).
Page 11
Technical Information PVG 100 Proportional Valve Group PVG 100 function PVG 100 sectional view PVP with open center Port Pilot Supply PVPD / PVPE Pressure Matching Facility Spool P301 234 Legend: 7 – Shock and suction valve, PVLP 1 – LS relief valve 8 –...
PVG 100 Proportional Valve Group PVG 100 function PVG 100 with closed center PVPV / PVPVP / PVPVM In load sensing systems the load pressure is led to the pump control via the LS connection (2 in the diagram below). When the work functions are in the spring neutral position the LS pressure is drained to tank via the PVG valve.
All PVG 100 modules contain an integrated T0 drain system to insure optimal performance for PVBZ and all electrical actuation offerings. T0 is most effective when connected directly to the hydraulic system reservoir independent of the main Tank return system.
Technical Information PVG 100 Proportional Valve Group PVG 100 function Legend: 7 – LS line 1 – LS relief valve 8 – Logic cartridge for POC 2 – LS connection 9 – Pressure compensator 3 – Priority spool for CF 10 –...
Technical Information PVG 100 Proportional Valve Group PVG 100 function Load sensing system characteristics: • Variable pressure and flow • Low pressure standby mode when flow is not needed • System flow adjusted to meet system requirements • Lower torque requirements during engine start-up •...
• Wood chippers PVG 100 main spool with pressure compensated control The PC control maintains constant system pressure in the hydraulic circuit by varying the output flow of the pump. Used with a closed center control valve, the pump remains in high pressure standby mode at the PC setting with zero flow until the function is actuated.
Technical Information PVG 100 Proportional Valve Group PVG 100 function Pressure compensated system characteristics • Constant pressure and variable flow • High pressure standby mode when flow is not needed • System flow adjusts to meet system requirements • Single pump can provide flow to multiple work functions •...
Technical Information PVG 100 Proportional Valve Group PVG 100 function P → A → F (Push-in) P → A → F (Pull-out) PVBS, main mpools for flow control (standard) With post-compensated valves, the A and B work port flow will depend on the pressure drop across the main spool PVBS.
Technical Information PVG 100 Proportional Valve Group Safety in application Building in safety All makes and all types of control valves (including proportional valves) can fail. Thus the necessary protection against the serious consequences of function failure should always be built into the system.
Page 20
Technical Information PVG 100 Proportional Valve Group Safety in application Control system example Legend: 1 – Main power supply 2 – Emergency stop/man present switch 3 – HMI/Joystick control 4 – Movement detection sensors 5 – Main controller 6 – PVG control valve 7 –...
Technical Information PVG 100 Proportional Valve Group Safety in application Electrical block diagram for above illustration Main power supply Emergency stop and Motion detection sensor (battery) Man present switch Main control valve Supply Main controller Supply Neutral Signal HMI / Joystick...
Page 22
Technical Information PVG 100 Proportional Valve Group Safety in application Typical wiring block diagram example Man present Emergency stop switch PVE 1 Neutral detection / Supply control PVEH with AMP connector signal ≠ Delay neutral Error PVE 2 PVEH Neutral detection / Supply control...
Technical Information PVG 100 Proportional Valve Group Safety in application Example of fault monitoring Similar to previous example using fault monitoring for deactivation of the hydraulic system with extra fault inputs using the PVE’s with DI (Direction Indication) function. Example of fault monitoring for deactivation of the hydraulic system...
Technical Information PVG 100 Proportional Valve Group Safety in application PVG 100 – Alternative LS dump or pilot supply disconnect • PVPP, pilot oil supply shut off • External cartridge valve connecting LS Pressure to Tank • External cartridge valve connecting main Pressure to Tank PVG 120 –...
Intermittent operation: the permissible values may occur for max. 10% of every minute. PVG 100-HF - 350 bar [5075 psi] rated for 250 000 cycles, max. continuous pressure 320 bar [4640 psi]. PVG 100-HF - High Flow option work section.
Technical Information PVG 100 Proportional Valve Group Technical data PVM, mechanical actuation PVM operating force Actuation Neutral position Max. spool travel Operating force PVM + PVMD, PVM + PVE 22 ± 3 N 28 ± 3 N (PVE without voltage applied) [5 ±...
Technical Information PVG 100 Proportional Valve Group Technical data For standard PVG 100 spools. PVEO Supply voltage U rated 12 V 24 V range 11 V to 15 V 22 V to 30 V max. ripple Current consumption at rated voltage 0.65 A @ 12 V...
Technical Information PVG 100 Proportional Valve Group Technical characteristics The characteristics in this catalog are typical measured results. During measuring a mineral based hydraulic oil with a viscosity of 21 mm /s [102 SUS] at a temperature of 50°C [122°F] was used.
Technical characteristics Caution Because of flow forces, cylinder differential areas, Danfoss recommends Ls margins under 25 bar [360 psi]. As noted above, work port flow is dependent upon the Ls margin set on the pump. PC pumps maintain a constant discharge pressure which is equal to the PC setting on the pump. Hence the Ls margin for PC pumps can be thought of as the difference between the PC setting and the load pressure.
Technical Information PVG 100 Proportional Valve Group Technical characteristics Pressure drop PVB for open spool in neutral position T neutral open center spool 100 130 3500 150/180 40/65 3000 2500 2000 1500 1000 l/min US gal/min V310204.A PVB with pressure compensation, closed center PVP...
Page 31
Technical Information PVG 100 Proportional Valve Group Technical characteristics Oil flow as a function of spool travel for spools A to F - 15 bar [218 psi] Set pressure difference between pump pressure and LS signal = 15 bar [218 psi] measured at the P-port of the valve.
Page 32
Technical Information PVG 100 Proportional Valve Group Technical characteristics 520L0720 • Rev EB • Jan 2014...
Technical Information PVG 100 Proportional Valve Group Hydraulic systems PVG 100 with variable displacement pump schematic example Inlet LS Relief setting PVLP setting in PVT should be a minimum of 30 bar above setting on the pump or external relief valve...
Non-flammable fluids Phosphate-esters (HFDR fluids) can be used without special precautions. However, dynamic seals must be replaced with FPM (Viton) seals. Please contact the Danfoss Sales Organization, if the PVG 100 valve is to be used with phosphate-esters. The following fluids should only be used according to agreement with the Sales Organization for Danfoss: •...
Pressure filters must be fitted to suit max. pump oil flow. Internal filters The filters built into PVG 100 are not intended to filter the system but to protect important components against large particles. Such particles can appear in the system as a result of pump damage, hose fracture, use of quick-couplings, filter damage, starting up, contamination, etc.
PV cover (PVH, PVMD, PVMR, PVMF or PVHC) would be on the “A” port side of the valve. The PVBS in PVG 100 are not symmetric. Because of this the “Load Sense” (Ls) holes in the PVBS main spool must be installed so that they are on the “B” port side of the PVB.
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers PVPF (Open Center) Inlet Modules - for Pumps with Fixed Displacement Symbol Description BSP port SAE Port 1 5∕16-12 Open center pump side module for pumps with fixed 12 bar...
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers Symbol Description BSP port SAE Port 1 5∕16-12 Max pump flow 250 l/min [66 US gal/min]. With pilot supply for PVE actuation. With pilot gauge port. gage Closed Center Pump Side Module for pumps with variable...
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers Symbol Description Code Number BSP port: SAE port: P = 1¼ Code 62 P = 1¼ Code 62 Metric flange LS, TO, Metric flange Pg, Pp = G ¼...
PVH, Cover for hydraulic remote control G¼ 157B0008 9∕16-18 UNF 157B0007 PVMR*, Cover for friction detent 157B0015 PVMF*, Mechanical float position lock, P -> A -> F 157B0005 * Opposite of PVM, not compatible with PVG 100 PVBZ. 520L0720 • Rev EB • Jan 2014...
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers PVEO, ON/OFF Actuation Symbol Description Hirschmann Deutsch 12 V 24 V 12 V 24 V 12 V 24 V PVEO ON/OFF 157B4216 157B4228 157B4901 157B4902 157B4291 157B4292 ON/OFF with ramp...
Without active elements 15∕8-UNF 161B2220 With T-port PVLP shock valve facility * Must use T0 equipped PVG32 Modules, for details see Danfoss Technical Information Basis Modules PVBZ, 520L0721. PVG 100 PVSI / PVT, Assembly Kit Description Code number 161B…. 1 PVB...
Page 46
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers Symbol Description PVBZ Without thermal With thermal relief relief valve 157B... valve 157B... Without compensator and load 6052 6452 drop check valve With pilot operated check valves on work port A and B Max.
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers PVG 32 Basic Modules with T0, PVB (Compatible with PVG 100) Symbol Description PVB Code number 157B..Without PVLP 63 With PVLP 63 Without load drop check 6010 6410 valve and pressure compensator.
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers Spools for Mechanical Float position, PVMF (not compatible with PVBZ 100) Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure) l/min [US gal/min] 40 [10.6] 65 [17.2]...
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers Standard Spools (Electrical and Mechanical Actuation), Full Open A/B → T and Neutral; Progressive Flow Characteristics Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure) l/min [US gal/min] 40 [10.6]...
Technical Information PVG 100 Proportional Valve Group Modules and Code Numbers High Flow Spools (Hydraulic and Mechanical Actuation) (continued) Symbol Pressure Compensated Flow (Specified flow is at 15 bar pump margin pressure) 210 l/min 240 l/min [55.4 US gal/min] [63.4 US gal/min]...
Technical Information PVG 100 Proportional Valve Group Dimensions PVG 100 with open center PVPF Legend: P: Pump port: G1 [15∕16 in-12UNF] Pp accumulator: G¼ [9∕16 in-18UNF] L: LS relief valve T0 and LS: G¼ [9∕16 in-18UNF] G: PVPE unloading valve P and Pp gauge: G¼...
Technical Information PVG 100 Proportional Valve Group Dimensions To avoid spool bind or leakage between sections caused by uneven mounting surfaces it is recommended to only use 3 of 4 mounting holes provided. 1 PVB 2 PVB 3 PVB 4 PVB...
Technical Information PVG 100 Proportional Valve Group Dimensions Legend: E: Port A and B PVB 100; G¾ [11∕16 inin - 12 UNF] Pp accumulator: G¼ [9∕16 in-18UNF] H : Port A and B PVB 32; G½ [7∕8 in - 14 UNF] T0 and LS: G¼...
Technical Information PVG 100 Proportional Valve Group Module selection chart Exploded view for module selection PVPP PVPD PVE, PVHC PVPE 1-12 PVPC PVBZ PVTI PVMD, PVH PVLP/A Assembly kit 157-699.11 PVP 100, Pump Side Module – Open center, PVPF with pilot supply (excludes PVPD/PVPE)
Page 61
Technical Information PVG 100 Proportional Valve Group Module selection chart PVP 100, Pump Side Module – Closed center, PVPV with pilot supply Port Closed center, PVPV with pilot supply for PVE for PVE and facility for PVE with for PVH/PVHC...
Page 62
Technical Information PVG 100 Proportional Valve Group Module selection chart PVPE, Accessory Module for PVP 100 Code no. 12 V 24 V Weight PVPE, Elec. unloading valve 155G5052* 155G5054* 0.7 kg [1.1 lb] * For PVPF only PVPC, External pilot supply Code no.
Page 63
Technical Information PVG 100 Proportional Valve Group Module selection chart PVLP, shock/and anti-cavitation valves (continued) Code no. 157B.… [psi] 460 725 914 116 Weight [kg [lb] 0.05 kg [17 lb] Accessory Module for PVP 100 Code no. 12 V 24 V...
The code number for the whole of the specified valve group (PVG No.) is entered here. In the event of a repeat order all you have to do is enter the number Danfoss has given on the initial confirmation of order.
Technical Information PVG 100 Proportional Valve Group Specification sheet Specification Form 520L0720 • Rev EB • Jan 2014...
Page 67
Technical Information PVG 100 Proportional Valve Group 520L0720 • Rev EB • Jan 2014...
Page 68
Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.