Huawei. The safety precautions in the document are related to only Huawei products. Huawei is not liable for any consequence that results from the violation of universal regulations for safety operations and safety codes on design, production, and equipment use.
Space Requirements (Unit: mm) RRU Dimensions Recommended Clearance for a Minimum Clearance for a Single Single RRU ≥300 ≥ 8 ≥500 Installation Modes On a metal pole On a wall On a U-steel On a U-steel...
Installation Modes The following figure shows the specifications of the metal pole, angle steel, and U-steel where the RRU is installed. 60mm ~ 114mm 8 0 m m 5 0 m m ~ ~ 6 3 m m 3 0 m m 50mm ~...
Installation Procedure Start Install the RRU on a Install the RRU on a Install the RRU on a Install the RRU on a metal pole wall U-steel angle steel (page 7~11) (page 12~14) (page15) (page15) Install the RRU cables (page16~22) Check the installation (page 23) Power on the RRU...
Installing the RRU on a Metal Pole Installing a Single RRU in Ordinary Mode 2. Install the auxiliary fixture between the nuts of the dual-nut bolt assembly on the main fixture. Ensure that the arrow Dual-nut bolt auxiliary fixture is assembly upward.
Page 9
Installing the RRU on a Metal Pole 4. Install the RRU on the main fixture. The screw is a non- fixed one and is for removing the RRU. 1. When you perform this operation, you need to place the foam pads or paper under the RRU to avoid any damage to the shell.
Installing the RRU on a Metal Pole Installing Two RRUs in Back-To-Back Mode 3. Install the second RRU on the main fixture in reverse mode. Ordinary mode Ordinary mode Installing the RRU on a Wall 1. Place the auxiliary fixture on the wall at the installation position , use a level bar to measure the levelness of the fixture, and then mark the anchor points by using a marking pen.
Page 11
Installing the RRU on a Wall 2. Drill holes at the anchor points and then install the expansion bolt assemblies. Bolt M10x65 Spring washer 10 Ø14 Plastic tube Flat washer 10 Expansion tube 90° Do not hammer the bolt After the expansion bolt 52~60mm entirely into the expansion tube, and leave 20 mm to...
Page 12
Installing the RRU on a Wall 4. Install the main fixture. 5. Install the RRU. 6. Install Multiple RRUs.
Installing the RRU on a U-Steel U-Steel Top view The procedure for installing the RRU on a U-steel is the same as that for installing the RRU on a metal pole. Installing the RRU on an Angle Steel Angle steel Top view The procedure for installing the RRU on an angle steel is the same as that for installing the RRU on a metal pole.
Installing the RRU Cables RRU Cable Connections Cable List Cable Connector Type Connector to… PGND OT terminal(M6) Grounding bolt on the RRU cable OT terminal Nearest grounding bar (16mm Antenna DIN male connector Ports labeled ANT_TX/RXA and ANT_TX/RXB on the jumper (Only the ANT_TX/RXA port supports the OOK signal).
Page 15
Installing the RRU Cables RRU Cable Connections Single RRU PGND cable Antenna jumper Power cable CPRI optical cable Alarm cable AISG multi-wire cable The RET/MON port on the RRU is AISG extension cable multi-functional, and can be installed with either AISG multi-wire cable or alarm cable.