If you experience any difficulty with the installation or operation of your new shower, then please refer to the Fault Diagnosis section, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found in the back of this guide.
Having done so, keep it handy for future reference. The Mira Vision Mixer Valve is designed to be used with the Mira Vision showerhead and fittings. Products Covered by this Guide Mira Vision Digital Mixer - High Pressure/Combi Valve Mira Vision Digital Mixer - Pumped Valve.
BONDING COMPLIES WITH THE “REQUIREMENTS FOR ELECTRICAL INSTALLATIONS”. The Mira Digital Mixer Valve is intended to be permanently connected to the fixed electrical wiring of the mains system. A means for electrical isolation of the appliance shall be provided in the fixed wiring in accordance with local wiring regulations.
Page 5
Caution! 1. Read all of these instructions and retain this guide for later use. 2. The electrical installation must comply to “BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant regulations, or any particular regulation or practice specified by the local electricity supply company. 3.
PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. Documentation 1 x Wireless Controller User Guide 1 x Showerhead User Guide 1 x Customer Support Brochure Digital Mixer Valve Digital Mixer - High Pressure/Combi Valve Digital Mixer - Pumped Valve...
Page 7
Ceiling Fed Fittings 1 x Plastic Pipe 2 x Spacers 1 x Ceiling Plate 1 x Showerhead 1 x Elbow Kit 1 x Extension 2 x Brackets 1 x Slide Bar Assembly 2 x Hex Screws 2 x Wall Plugs 1 x Hose 2 x Rubber Washers 2 x 45mm Screws...
Page 8
Rear Fed Fittings 2 x Brackets 2 x End Plugs 1 x Showerhead 1 x Slide Bar Assembly 1 x Hose 2 x Rubber Washers 1 x Right Angle Connector (RAC) Kit 2 x Hex Screws 1 x Right Angle Connector Shroud 2 x Wall Plugs 2 x 45mm Screws...
SPECIFICATIONS Standards and Approvals The Mira Vision complies with all relevant directives for CE marking. The Mira Vision is a type 1 electronic, independently mounted control for surface mounting. The Mira Vision is in compliance with the essential requirements of the R&TTE directive 1999/5/EC.
Page 10
Mira Digital Mixer Valve Pumped Pressures Maximum Static Pressure 100 kPa (1 bar) = 10 m max. total head Maximum Maintained Pressure 100 kPa (1 bar) = 10 m max. total head Minimum Maintained Pressure 1 kPa (0.01 bar) = 0.1 m min. total head...
• Interference from other radio signals can dramatically reduce the ability of the Mira Vision User Interface / digital mixer to register or communicate. This may include; mobile phones, radio control boiler thermostats, wireless broadband routers, radio control toys, cordless phones, remote outdoor weather stations etc.
Page 12
Boiler warm Key to Symbols Digital Mixer Valve (HP) Float Valve ISOLATE MAINS ELECTRICITY BEFORE REMOVING COVER! DIGITAL MIXER 2 WIRELESS MIRA DM2 WIRELESS Isolating Valve HP/COMBI 1666.009 N85A MANUFACTURED POWER: 230 V AC 20 W PROTECTION: IP24 MIN. SUPPLY PRESSURE: 50 kPa (0.5 bar) MAX.
A flow regulator may need to be used to ensure that the Digital Mixer Valve can deliver a full range of water temperatures. The table indicates the flow regulator to be fitted in the hot water inlet of the Mira Digital Mixer Valve.
Page 14
KOHLER MIRA LTD. CHELTENHAM GL52 5EP TEL: (+44) 0870 241 0888 www.mirashowers.com COLD F9001 Mira Vision Shower 90° Fittings 30° - 60° Air Separation cold The shower control must be fed from a cold water storage cistern and a hot water cylinder providing nominally equal pressures.
Page 15
Typical Examples of Poor Plumbing and Installation Practices DO NOT: • Install the Digital Mixer Valve where it can become frozen • Position the Digital Mixer Valve where maintenance access is poor • Install into a system where the cold water cistern holds less than 230 litres •...
Outlet Metal pipework must be earth bonded Mira Vision Shower Fittings & Wireless Controller A separate, permanently connected supply must be taken from the ring main to the appliance through a 3 amp double pole switched fuse spur providing a minimum 3mm contact separation gap in each pole.
Page 17
Long inlet pipework (dead-legs) should be kept to a minimum to avoid temperature fluctuations. Supply pipework layout must be arranged to minimize the effect of other outlet usage upon the dynamic pressures at the Digital Mixer Valve inlets. To eliminate pipe debris it is essential that supply pipes are thoroughly flushed through before connection to the Digital Mixer Valve.
Up to 4.5 m total distance to 3 amp switched Right Angle Connector (RAC) fused spur Up to 3 m ISOLATE MAINS ELECTRICITY BEFORE REMOVING COVER! DIGITAL MIXER 2 WIRELESS MIRA DM2 WIRELESS HP/COMBI 1666.009 N85A MANUFACTURED POWER: 230 V AC 20 W PROTECTION: IP24 MIN.
Page 19
The following procedure details how to assign the Wireless Controller to the Digital Mixer Valve and test the remote signal strength. Note! No plumbing connections are required for this test. Note! Other radio signals from sources such as mobile phones, radio controlled boiler thermostats, wireless broadband etc.
Page 20
Place Wireless Controller in approximate final position (no more than 10 m from Digital Mixer Valve) and test wireless signal by pressing the “ ” and adjusting the temperature. If temperature display remains unchanged and “out of range” symbol is displayed, units are unable to communicate with each other.
Page 21
Drill and plug the fixing holes. Note! Installers may wish to use alternative cavity fixings, when installing onto a dry lined, stud partition, shower cubicle or laminated panel wall structures. However, these methods of fixing are beyond the scope of this guide.
Shower Fittings - Ceiling Fed Suitable for solid, dry-lined, stud partition, shower cubicle or laminated panel walls. The Slide Bar should be fixed to the wall at a convenient height for all the family. It should be positioned so that water sprays down the centre of the bath, or away from the opening of a shower cubicle.
Page 23
Drill and plug Slide Bar Assembly fixing holes. Insert fixing screws through holes in Wall Brackets and fix to wall. Do not fully tighten. Use template to set correct distances between Wall Brackets. Fully tighten screws. Use longer fixing screws if using spacers supplied.
Page 24
Fit Slide Bar Assembly over Wall Brackets and secure with screws supplied. (Do not overtighten.) Connect ceiling extension tube. Feed plastic pipe up through the slide bar and extension into ceiling. Do not allow any debris to block the plastic pipe. Note! If plastic pipe requires shortening, make sure there is enough length to fit elbow (supplied)
Place first washer in end of hose, then attach to pipe end. Do not fit showerhead until after pipework has been fully flushed through. See section “Commissioning”. Shower Fittings - Rear Fed Suitable for solid, dry-lined, stud partition, shower cubicle or laminated panel walls.
Page 26
Insert fixing screws through holes in Wall Brackets and fix to wall. Do not fully tighten at this stage. Use template to set correct distances between Wall Brackets. Fully tighten screws. Note! Slots in Wall Brackets allow for adjustment. Use one horizontal slot and one vertical slot.
Page 27
The end of the 15 mm pipework from the outlet of the shower must protrude through the finished wall surface by 20 - 23 mm. Note! The pipe work must protrude through the wall between 20 - 23 mm from the finished surface of the wall.
Page 28
Place the backplate over the Backplate outlet pipe with the arrow pointing vertically up and tighten the two backplate screws. Make sure that Copper the foam seal abuts the finished wall Pipe surface. 2 x Screws Check that the blue ‘O’ seal is fitted inside the backplate nut.
Wireless Controller Suitable for solid, dry-lined, stud partition, shower cubicle or laminated panel walls. The Wireless Controller should be fixed to the wall at a convenient height for all the family. It should be positioned so that water does not spray over it when the Showerhead is held on the Slide Bar.
COMMISSIONING Connect battery to Wireless Controller, display appears. Turn on electrical supply to Digital Mixer Valve. Make sure the end of the hose is in either the bath, shower tray or other water catchment area. Press “ ” button and reduce temperature to full cold “CLd”.
Page 31
Run cold water through (approximately 2 minutes) and check entire installation for water leaks. Press “ ” to turn shower off. Fit the second hose washer and showerhead. Press “ ” to turn shower on. Test operation of shower by increasing/decreasing both temperature and flow controls.
RE-REGISTERING If the wireless controller has previously been assigned to the digital mixer and communication problems are encountered, a re-registering of the wireless controller may be required. A re-registering of the wireless controller must also be performed should the control PCB in the Digital Mixer Valve be replaced.
Refer to “Re-Registering”. Reassignment required. Digital Mixer Valve failure. Contact Kohler Mira Ltd. Wireless Controller failure. Contact Kohler Mira Ltd. Radio frequency interference E n s u r e a l l o t h e r r a d i o transmitting devices, including mobile phones, are switched off.
Page 34
Symptoms Probable Cause Possible Remedy Low or no water flow. 1. Wireless Controller. Controller not assigned to Repeat commissioning Digital Mixer Valve. sequence. 2. Digital Mixer Valve. No power to Digital Mixer Check electrical connection Valve. and supply. Isolators closed. Open valves.
Page 35
Refer to User Guide - Maximum blend temperature Incorrect maximum too hot or too cold. temperature setting. “Maximum Shower Water Temperature”. Continuous flow. Shower will Wireless Controller or Digital Isolate power and water not shut off. Mixer Valve failure. supplies. Contact Kohler Mira Ltd.
Page 36
Symptoms Probable Cause Possible Remedy Shower runs for a short time Air is being sucked down The hot draw off pipe is (30 - 60 seconds) then flow the vent pipe. (Gravity fed positioned too high in relation reduces, splutters or stops. system).
MAINTENANCE General Read the section “Important Safety Information” first. Before replacing any parts ensure that the underlying cause of the malfunction has been resolved. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure there are no leaks. Warning! There are no user serviceable components beneath the cover of the appliance.
ACCESSORIES Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants. Mira Standard Grab Bars Shower Seat Premium Shower Seat White - 2.1536.128 White/Chrome - 2.1731.001 300 mm - 2.1605.070 White/Chrome - 2.1536.129 450 mm - 2.1605.071...
DISPOSAL AND RECYCLING End of Product Life When this appliance has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy. Batteries Spent batteries should not be disposed of with normal household waste. Contact your local authority for information on waste disposal and recycling.
If your product does not function correctly when you fi rst Fax: 01242 282595 use it, contact your installer to check that it is installed By Post: Mira Customer Services Dept, Cromwell Road, and commissioned in accordance with the instructions in Cheltenham, Gloucestershire, GL52 5EP this manual.
Page 45
Electric Showers Digital Showers Mixer Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more Stuart Turner Shower Pumps Salamander Shower Pumps...
Need help?
Do you have a question about the Vision and is the answer not in the manual?
Questions and answers