PS4000 Hardware Maintenance
Table 3-2: Ethernet Port LED Descriptions
LED Location
Left side of each
port
Right side of each
port

Identifying Control Module Failures

You can identify a failure in a control module by:
LEDs. See Interpreting Control Module LEDs on page 3-2.
Messages. A message on the LCD panel (located behind the bezel), on the
console, in the event log, or in the Group Manager GUI Alarms panel
describes a control module failure.
Group Manager GUI and CLI output. The Member Controllers window or
the
member select show controllers
control module status
When viewed from the rear of the array, CM0 is on the right, and CM1 is on the
left. See Figure 1-3.
If a control module fails, see your PS Series support provider for a replacement.

Understanding Failover Behavior

In a dual control module array, only one control module is active (serving network
traffic) at one time. Each control module includes a battery-backed write cache for
storing recently-used data. For redundancy, the cache on the secondary control
module mirrors the data that is stored in the cache on the active control module.
The active control module can use a network interface only if there is a cable
connected to the port on the active control module. Therefore, you should connect
a cable to a network interface port on each control module to make sure that both
control modules can access an interface.
Color
Description
Off
No power or not connected to network.
Green
Connected to network.
Off
No power, not transmitting, or not receiving.
Green
Transmitting or receiving.
not installed
Maintaining Control Modules
command output shows the
.
3–3