Trouble Shooting - Salamander Pumps EVE Installation And Warranty Manual

Table of Contents

Advertisement

Trouble shooting

Error Code
Likely Problems
Flash
Eve is detecting a potential
dripping tap, or slow system leak.
Steady
A drip or system leak has been
found. Protection has been
initiated, and the pump has
locked out.
Flash
EVE is detecting aeration or water
starvation in pump chambers.
Steady
Excessive aeration or water
starvation has been found.
Protection has been initiated,
and the pump has locked out.
Flash
EVE is regulating the motor speed
in order to cool, and maintain
pump performance.
Steady
An issue with overheating has
been found. Protection has been
initiated, and the pump has locked
out.
Flash
Mains Voltage input, the mains
input is varying beyond pump
limits, or the mains has been
disconnected.
Steady
There is a motor fault. Either a
restriction or blockage of the
motor.
Solution
Find the dripping tap, or system leak, and repair.
Once the issue has been identified and resolved,
the pump should be isolated from the mains for
1 minute, then reconnected, to reset the lockout.
Find the restriction on input flow, or air leak, and
repair. Once the issue has been identified and
resolved, the pump should be isolated from the
mains for 1 minute, then reconnected, to reset the
lockout.
Find the reason for the pump overheating, and
allow to cool. Once the issue has been identified
and resolved, the pump should be isolated from the
mains for 1 minute, then reconnected, to reset the
lockout.
Find the reason for the variation in mains inlet
voltage, and repair.
Possible restriction to the impeller, contact
PumpWise 0191 516 2002
17

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVE and is the answer not in the manual?

Questions and answers

Table of Contents