(3) Display Component Specifi cations
Warning display (red)
During warnings, TEST/WARNING LED (D052) fl ashes.
Forced setting display (red)
Upon forced settings during normal display, the TEST/WARNING LED (D052) lights.
During display of forced settings on the menu item display, the TEST/WARNING LED (D052) lights. (This
may be used to search for forced setting items during setting.)
Level LED display (green)
The Level LED (D053) displays the setting menu stage level and other information.
Level 0 is unlit, Level 1 is light, Level 2 is fl ashing.
Displays immediately after power is turned ON
When the power supply is turned on, the following displays appear.
• 7-segment LED, TEST/WARNING LED (D052), Level LED (D053) light up
• Model name display (1 second)
• Version display
Example:  (All segments light)
Example:  (Model name display)
Example:  (Version display)
When the power supply is turned on while pressing the SET (S007) key, the contents of the nonvolatile memory
can be cleared.
•Memory clear procedure
1. Turn on the power supply while pressing the SET (S007) key. After 1 second or more, "  " will
be displayed.
2. Press the SET (S007) key again. Activating the nonvolatile memory erase function at this time will display
"  ".
3. Check for power on display
"(If the  display fails to appear, repeat the aforementioned operation until it does appear.)"
When the memory is cleared at this time, all the contents of the nonvolatile memory are reset to the initial
state.
Outdoor unit normal display
Example:      
(5 seconds)
(1 second)
Number of indoor units (20 units)
System address (01)