Allen-Bradley 1734-AENTR Installation Instructions Manual

Allen-Bradley 1734-AENTR Installation Instructions Manual

Point i/o dual port ethernet/ip adapter
Hide thumbs Also See for 1734-AENTR:

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1734-AENTR and is the answer not in the manual?

Questions and answers

Summary of Contents for Allen-Bradley 1734-AENTR

  • Page 1: Table Of Contents

    Installation Instructions POINT I/O Dual Port EtherNet/IP Adapter Catalog numbers 1734-AENTR Table of Contents Topic Page Important User Information Environment and Enclosure Preventing Electrostatic Discharge North American Hazardous Location Approval European Hazardous Location Approval About The Adapter Before You Begin...
  • Page 2: Important User Information

    2 POINT I/O Dual Port EtherNet/IP Adapter Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid-State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid-state equipment and hard-wired electromechanical devices.
  • Page 3: Environment And Enclosure

    POINT I/O Dual Port EtherNet/IP Adapter Environment and Enclosure ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments.
  • Page 4: North American Hazardous Location Approval

    4 POINT I/O Dual Port EtherNet/IP Adapter North American Hazardous Location Approval The following information applies when Informations sur l’utilisation de cet équipement operating this equipment in hazardous en environnements dangereux: locations: Products marked "CL I, DIV 2, GP A, B, C, D" are suitable Les produits marqués "CL I, DIV 2, GP A, B, C, D"...
  • Page 5 POINT I/O Dual Port EtherNet/IP Adapter ATTENTION: If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product.
  • Page 6: About The Adapter

    This adapter is for the POINT I/O backplane that provides connectivity to an EtherNet/IP network with two RJ-45 connectors for 2 port pass-through to support daisy-chain or ring, and the existing star and tree network topologies. 1734-AENTR Adapter 44849 Publication 1734-IN040C-EN-P - December 2018...
  • Page 7: Before You Begin

    To effectively use your adapter, note the following considerations. Determine Compatibility RSLogix 5000® version 17 or greater must be used for the 1734-AENTR Add-on Profile. The 1734-AENTR adapters will accept I/O connections with the electronic keying for the 1734-AENT. This allows the 1734-AENTR adapter to be used in a daisy-chain topology with the 1734-AENT profile used for the 1734-AENTR.
  • Page 8: Configure Autobaud

    8 POINT I/O Dual Port EtherNet/IP Adapter Configure Autobaud The adapter cannot reconfigure an I/O module that you previously configured to operate at a fixed baud rate. When you reuse a POINT I/O module from another POINT I/O system, configure the module to autobaud before using it with the adapter. Install the Adapter Follow this procedure to install the adapter on the DIN rail.
  • Page 9: Set The Network Address

    POINT I/O Dual Port EtherNet/IP Adapter ATTENTION: Do not remove or replace an Adapter Module while power is applied. Interruption of the backplane can result in unintentional operation or machine motion. WARNING: If you connect or disconnect the communications cable with power applied to this module or any device on the network, an electrical arc can occur.
  • Page 10 10 POINT I/O Dual Port EtherNet/IP Adapter Network Address Thumbwheel Network node address 1734-AENTR POINT I O pen push thumbwheel – Module Press the center of either Status Network Activity the + or - buttons to change Network Status the number...
  • Page 11: Replace The Adapter

    POINT I/O Dual Port EtherNet/IP Adapter Replace The Adapter Use these procedures to install a replacement adapter to an existing system. Disconnect the Ethernet connector(s) from the adapter. Pull up on the Removable Terminal Block (RTB) handle to remove the terminal block.
  • Page 12 12 POINT I/O Dual Port EtherNet/IP Adapter Press firmly to seat the adapter on the DIN rail, noting that the adapter locking mechanism will snap into place. Set the node address on the Node Address pen push thumbwheel using a pen tip. Press a pen tip into the center of the button cross, perpendicular to the button.
  • Page 13: Wire The Adapter

    POINT I/O Dual Port EtherNet/IP Adapter Wire The Adapter 1734-AENTR POINT I O Module Status Network Activity Network Status Point Bus Status Link 1 Activity/ Status System Power Field Power Ethernet RJ-45 connectors Chas Gnd Link 2 Activity/ Status NC = No Connection...
  • Page 14 14 POINT I/O Dual Port EtherNet/IP Adapter WARNING: When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a suitable enclosure with proper wiring method that complies with the governing electrical codes. WARNING: If you connect or disconnect wiring while the field-side power is on, an electrical arc can occur.
  • Page 15: Interpret Status Indicators

    POINT I/O Dual Port EtherNet/IP Adapter Interpret Status Indicators Refer to the following diagram and table for information on how to interpret the status indicators. Status Indicators 1734-AENTR POINT I O Module status Module Status Network Network activity Activity Link 1 activity/...
  • Page 16 16 POINT I/O Dual Port EtherNet/IP Adapter Indicator Status for Modules Indicator Status Description Network No link established with Port 1 or Port 2. activity Flashing green Transmit or receive activity present on Port 1 and/or Port 2 @ 100 Transmit or receive activity present on Port 1 and/or Port 2.
  • Page 17: Specifications

    (for digital, analog, and specialty modules) connections • 31 direct connections • 1734-AENTR, 1734-AENTRK backplane current output = 0.8 A. • Actual number of modules can vary. • Add up current requirements of modules you want to use to make sure they do not exceed the amperage limit of 0.8 A for...
  • Page 18 18 POINT I/O Dual Port EtherNet/IP Adapter Power Supply Attribute Value Input voltage rating 24V DC @ 10A Input voltage, range 10...28.8V DC Field side power, max 24V DC @ 400 mA Inrush current, max 6 A for 10 ms Input overvoltage protection Reverse polarity protected POINTBus output current, max...
  • Page 19 POINT I/O Dual Port EtherNet/IP Adapter General Specifications Attribute Value Input overvoltage protection Reverse polarity protected Thermal dissipation, max 21.5 BTU/hr @ 28.8V DC Isolation voltage 50V (continuous), Reinforced Insulation Type, between all circuits Type tested @ 500V AC for 60 s Field power supply 10...28.8V DC @ 10A Field power output...
  • Page 20 20 POINT I/O Dual Port EtherNet/IP Adapter Environmental Specifications Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20...55 °C (-4...131 °F) Temperature, surrounding air, max 55 °C (131 °F) Temperature, nonoperating IEC60068-2-1 (Test Ab, Unpackaged Nonoperating Cold)
  • Page 21 POINT I/O Dual Port EtherNet/IP Adapter Certifications Certification (when Value product is marked) c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. European Union 2014/30/EU EMC Directive, compliant with: EN 61326-1;...
  • Page 22: Additional Resources

    Grounding Guidelines, publication 1770-IN041. If you would like a manual, you can: • download a free electronic version from the internet: http://www.rockwellautomation.com/literature/ • purchase a printed manual by contacting your local Allen-Bradley distributor or Rockwell Automation representative. Publication 1734-IN040C-EN-P - December 2018...
  • Page 23 POINT I/O Dual Port EtherNet/IP Adapter Notes: Publication 1734-IN040C-EN-P - December 2018...
  • Page 24 Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, ArmorPOINT, POINT I/O, Rockwell Automation, Rockwell Software, RSLogix 5000, and TechConnect are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

Table of Contents

Save PDF