List Of Warning Codes - Panasonic LB-DH7 Series Operator's Manual

Hide thumbs Also See for LB-DH7 Series:
Table of Contents

Advertisement

Others

List of warning codes

Email
Code
notification
W1000
W1000-0
W1000-1
W1001
±
W1010
±
W1030
s
W1041
±
W1042
±
W1050
s
W1102
s
W1103
s
W1104
s
Errors and warnings
SNMP trap
notification
A fault has been detected in the external power supply unit. (When
"Enable Power Supply Monitoring" (
)Replace the external power supply with reference to the manual
for the external power supply in use.
≥ Values written in the "0xXX" format are the hexadecimal numbers
converted from binary numbers that denote the locations of external
power supply units with faults.
(Examples) 0xXX: indicates a fault in the external power supply unit in
the leftmost slot of the shelf;
0x05: indicates faults in the external power supply units in the leftmost
slot of the shelf and the third slot from the left side of the shelf
A fault has been detected in the external power supply unit. (When
"Enable Power Supply Monitoring" (
≥ Values written in the "0xXX" format are the hexadecimal numbers
converted from binary numbers that denote the locations of external
power supply units with faults.
(Examples) 0xXX: indicates a fault in the external power supply unit in
the leftmost slot of the shelf;
0x05: indicates faults in the external power supply units in the leftmost
slot of the shelf and the third slot from the left side of the shelf
Communication with the external power supply unit has failed.
(When "Enable Power Supply Monitoring" (
A fault has been detected in the fan of the unit or the peripheral circuit of the fan.
±
It needs to be repaired.
The software update has failed.
±
)Refer "Software problems" (
Email submission to the SMTP server has failed.
±
)Check if the network setting for the SMTP server is correct.
Detected that the life of the HDD in the server connected to the unit
is nearly at its end.
±
)We recommend to replace the flash memory unit.
≥ This warning function detects only the life of the HDD in a recommended server.
The rotation speed of fan has dropped.
±
)It is recommended that the fan and the peripheral circuit be maintained.
Could not detect any magazine.
)Withdraw the magazine drawer to make sure the installation of
s
magazine is correct. (
If the problem persists, please contact your support service provider. (
The command for turning on or off was set while the unit was
s
processing the previous command for turning itself on or off.
)Wait until the unit turns on or off.
The unit cannot be turned off because the software is being updated.
s
)Try again after the update is complete.
The unit cannot be turned off because the magazine eject mode is set.
s
)Turn off the magazine eject mode on the application, and try again.
80
Action to be taken
47) is disabled (default).)
47) is enabled.)
47) is enabled.)
72) to take proper action.
20)
83)