Summit Series
D
- Equipment Maintenance
15 - Error code definitions-Controls
The DISPLAY PANEL located on the ground (lower) control panel indicates the present operating
status of the aerial work platform. If an error condition is detected, the appropriate error code will be
displayed on this panel.
Refer to Table following paragraph to resolve the error Or Contact Haulotte Group Customer Service
Department: at 1-800-537-0540 or visit Haulotte Group online at www.haulotte-usa.com for any
additional questions.
Error
message
Machine went out of
001
level with use, moment
MACHINE IS
sense or load sense
IN DOWN
circuits have detected
ONLY MODE
an overload
002LOSS OF
Lower Control has lost
PLATFORM
RS485 communication
COMMUNICA
with Platform Control
TION
003 LOSS OF
Lower Control has lost
DRIVE
RS485 communication
COMMUNICA
with Drive Control
TION
004 LOSS OF
Lower Control has lost
PC
RS232 communication
COMMUNICA
with PC
TION
005
Platform Control has
PLATFORM
detected a stuck or
CONTROL
pressed key on power
HAS STUCK
up
KEY
006DRIVE
Drive Control has
CONTROL
detected a stuck or
HAS STUCK
pressed key on power
KEY
up
007 DRIVE
Drive Control has
CONTROL
detected a stuck or
HAS STUCK
pressed joystick on
JOYSTICK
power up
008 GROUND
Lower Control has
CONTROL
detected a stuck or
HAS STUCK
pressed key on power
KEY
up
88
2420341380
Error definition
To simulate error
Level machine, raise
boom and tilt level
sensor
Open Platform Control
and remove green wire
from J1
Open Drive Control and
remove green wire
from J1
Connect a PC without
running the
configuration program
On Platform Control
hold down a key at
power up
On Drive Control hold
down a key at power up
On Drive Control hold
joystick to side at power
up
On Lower Control hold
down a key at power up
To clear error
This is a self clearing
error. When error
condition is corrected,
error is cleared.
This is a latched error.
Power must be cycled
to clear error.
This is a latched error.
Power must be cycled
to clear error.
This is a self clearing
error. When error
condition is corrected,
error is cleared.
This is a latched error.
Power must be cycled
to clear error.
This is a latched error.
Power must be cycled
to clear error.
This is a latched error.
Power must be cycled
to clear error.
This is a latched error.
Power must be cycled
to clear error.
E 02.12
Comments
Error will be displayed
only if boom is raised
The Platform Control
"Engine On" LED will
also blink a 2 blink
error code
Machines with Drive
option only. The Drive
Control "Engine On"
LED will also blink a 2
blink error code
Error message will only
be display if connected
to a PC that is not
communicating
The Platform Control
"Engine On" LED will
also blink a 1 blink
error code
Machines with Drive
option only. The Drive
Control "Engine
On"LED will also blink
a 1 blink error code
Machines with Drive
option only. The Drive
Control "Engine
On"LED will also blink
a 3 blink error code
The Lower Control
"Power" LED will also
blink a 1 blink error
code