# fx -x "dksc(8,0,15)"
fx version 6.5, Jan 11, 2000
...opening dksc(8,0,15)
...drive selftest...OK
fx: Warning: invalid label from disk driver, ignored
Scsi drive type == HITACHI
...creating default bootinfo
...created default partitions, use /repartition menu to change
...creating default volume directory
----- please choose one (? for help, .. to quit this menu)-----
[exi]t
[b]adblock/
fx> /label/set/param
fx/label/set/parameters: Error correction = (enabled)
fx/label/set/parameters: Data transfer on error = (enabled)
fx/label/set/parameters: Report recovered errors = (enabled)
fx/label/set/parameters: Delay for error recovery = (enabled)
fx/label/set/parameters: Err retry count = (0)
fx/label/set/parameters: Transfer of bad data blocks = (disabled)
fx/label/set/parameters: Auto bad block reallocation (write) = (enabled)
fx/label/set/parameters: Auto bad block reallocation (read) = (enabled)
fx/label/set/parameters: Read ahead caching = (enabled)
fx/label/set/parameters: Write buffering = (enabled)
fx/label/set/parameters: Drive disable prefetch = (0)
fx/label/set/parameters: Drive minimum prefetch = (0)
fx/label/set/parameters: Drive maximum prefetch = (0)
fx/label/set/parameters: Drive prefetch ceiling = (0)
fx/label/set/parameters: Enable CTQ = (disabled) enable
fx/label/set/parameters: CTQ depth = (2) 32
fx/label/set/parameters: Read buffer ratio = (0/256)
fx/label/set/parameters: Write buffer ratio = (0/256)
* * * * * W A R N I N G * * * * *
about to modify drive parameters on disk dksc(8,0,15)! ok? yes
----- please choose one (? for help, .. to quit this menu)-----
[exi]t
[b]adblock/
fx> exi
label info has changed for disk dksc(8,0,15). write out changes? (yes) yes
Figure 3-5
Hitachi Universal Storage Platform V/VM Configuration Guide for SGI
OPEN-3-CVS
[d]ebug/
[l]abel/
[exe]rcise/
[r]epartition/
[d]ebug/
[l]abel/
[exe]rcise/
[r]epartition/
Enabling Command Tag Queuing (CTQ) and Setting the
Queue Depth
Configuring the New Disk Devices
Start fx and enter USP device.
5244
[a]uto
Set the device parameters.
Enter desired queue depth.
[a]uto
Exit the fx utility.
®
®
IRIX
Host Attachment
Enter "enable".
Enter "yes".
Enter "yes".
3-7