Simplex TrueAlarm 4008-9102 Manual

Simplex TrueAlarm 4008-9102 Manual

Fire alarm control panels for idnet addressable devices and addressable smoke detection

Advertisement

UL, ULC, CSFM Listed; FM Approved;
MEA (NYC) Acceptance*
Features
Control panel operator convenience features:
 Wide viewing angle 2 x 20 (40 character) alphanumeric
LCD and dedicated LEDs provide convenient panel
status information
 Operation is programmable using a multi-function
keypad and the panel LCD or via service computer (PC)
 RS-232 service port provides upload/download PC
access for panel configuration and event history logs
 Software updates are via PC download
 Convenient library of standard custom label terms
 Standard on-board DACT provides: Contact ID, 3/1, 4/2,
BFSK, and SIA formats
 WALKTEST silent or audible system test
 Voltage and current for both the battery charger and the
battery can be displayed at the front panel LCD
Addressable Devices:
 Using IDNet communications, up to 200 addressable
TrueAlarm detection points or addressable device points
are available (see page 3 for details)
Two Standard Notification Appliance Circuits (NACs):
 Class A or Class B outputs with solid state overcurrent
protection per NAC, each rated for 2 A
 Selectable for Simplex
®
horn/strobe control or synchronized strobe control
Standard Power Supply:
 Provides 3 A maximum @ nominal 24 DC
 Automatic input power selection operates with 120 VAC
or 240 VAC, 50 or 60 Hz
 On-board temperature compensated battery charger for
up to 12.7 Ah batteries in cabinet (UL and ULC) and up
to 25 Ah batteries in separate cabinet (UL only)
Additional standard features:
 Programmable Active Status Reminder
 Two auxiliary relays
 NACs, Relay outputs, and communications circuits
are power limited (AC input, battery circuits, and City
Circuit Module outputs are non-power limited)
 Available with beige or red cabinet
 UL listed to Standard 864
Available option modules:
 Door mounted 24 LED annunciator (standard on ULC
models)
 3 A Expansion Power Supply with two on-board 2 A
NACs that operate the same as standard NACs
 City Interface Module and Auxiliary Relay Module
 Remote LCD and LED/Switch Annunciators
TrueAlarm Addressable Fire Alarm Control Panels
4008 Fire Alarm Control Panel for IDNet Addressable
Devices and TrueAlarm Addressable Smoke Detection
SmartSync two-wire
FIRE
SYSTEM
SYSTEM
ALARM
SUPERVISORY
TROUBLE
ALARM
SUPV
TROUBLE
ACK
ACK
ACK
4008-9102 (Beige) Standard Control Panel
F i r e
A l a r m
A n n u n c i a t o r
FIRE
SYSTEM
SYSTEM
ALARM
SUPERVISORY
TROUBLE
ALARM
SUPV
TROUBLE
ACK
ACK
ACK
4008-9122 (Beige) Control Panel with 24 LED Annunciator
(required for ULC applications)
Description
For areas requiring up to 200 addressable input devices and
up to 4 NACs, the Simplex 4008 Series fire alarm control
panels provide flexible initiating circuit monitoring,
extensive programmable control capability, and LCD
annunciated circuit-specific 20 character custom labels.
*
See page 2 for additional ULC and MEA information. This product has been approved by
the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California
Health and Safety Code. See CSFM Listing 7165-0026:318 for allowable values and/or
conditions concerning material presented in this document. It is subject to re-examination,
revision, and possible cancellation. Additional listings may be applicable, contact your local
Simplex product supplier for the latest status. Listings and approvals under Simplex Time
Recorder Co. are the property of Tyco Fire Protection Products.
ALARM
AC
SILENCED
POWER
ALARM
SYSTEM
SILENCE
RESET
CAUTION
DISCONNECT
BATTERY AND
A. C. POWER
BEFORE
SERVICING
ALARM
AC
SILENCED
POWER
ALARM
SYSTEM
SILENCE
RESET
CAUTION
DISCONNECT
BATTERY AND
A. C. POWER
BEFORE
SERVICING
S4008-0001-8 8/2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TrueAlarm 4008-9102 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Simplex TrueAlarm 4008-9102

  • Page 1 Available option modules: revision, and possible cancellation. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time  Door mounted 24 LED annunciator (standard on ULC Recorder Co. are the property of Tyco Fire Protection Products.
  • Page 2: Product Selection

    12.7 Ah per ULC-S527. (Up to 12.7 Ah batteries fit in full complement of TrueAlarm features, contact your local the cabinet, larger batteries require an external cabinet.) Simplex product supplier.) Panel electronics can measure and display voltage and Two, 2 A On-Board NACs...
  • Page 3: Diagnostics And Default Device Type

    Diagnostics and Default Device Type TrueAlarm Addressable Detection. IDNet addressable Status Monitoring. 4008 TrueAlarm operation provides device compatibility includes Simplex TrueAlarm the ability to automatically indicate when an addressable photoelectric smoke and temperature sensors. The 4008 fire detector is dirty or excessively dirty. The NFPA 72...
  • Page 4 Remote NAC Extender S4009-0002 4 extenders max/NAC; 4008 uses NAC output to provide control Note: Contact your local Simplex Product Supplier for additional compatible peripherals. Remote Annunciator Options The 4008 supports up to four annunciator options 4606-9101 LCD Annunciator Features: including: ...
  • Page 5: Specifications

    Shielded wire may provide protection from unexpected sources of interference and Shielded twisted pair (STP) may be required for some applications; review system with your local Simplex product supplier Up to 4000 feet (1219 m) with 125 devices; 32 ...
  • Page 6 Supervisory and Alarm Currents Model Module Supervisory Alarm 4008-9101 Standard fire alarm control panel 135 mA + 0.8 mA per IDNet device 190 mA + 1 mA per IDNet device 4008-9102 4008-9121 Control panel with 24 LED Annunciator 153 mA + 0.8 mA per IDNet device 240 mA + 1 mA per IDNet device 4008-9122 4008-9801...
  • Page 7 SmartSync 2-wire horn/strobe control; horn on until silenced, strobe on until reset Provides Wheelock strobe synch protocol when using only Wheelock strobes on panel, not to be mixed with WHEELOCK Simplex strobes UTILITY Utility signal, generic non-alarm Relay Operation Modes The following relay operations are selectable from either the front panel or the PC programmer.
  • Page 8 Trouble annunciation (shown labeled as NAC 1-4) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA).

This manual is also suitable for:

Truealarm 4008- 9121Truealarm 4008-9101Truealarm 4008-9122

Table of Contents