Page 2
Please take note that this manual uses the following symbols to emphasize particular information: ⚠ WARNING Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death. CAUTION Denotes an instruction which, if not followed, may severely damage the unit and/or its components. NOTE: Indicates supplementary information needed to fully complete an instruction.
TABLE OF CONTENTS FOR THE USER ........4 7. CONTROLS ..........11 7.1 Setting Extended Defrost ........11 1. USING THIS UNIT ........4 7.2 Electrical Connection to Optional Wall Control ..12 1.1 Your ventilation system ...........4 7.2.1 Altitude or Platinum ..........13 1.2 Integrated Control...........4 7.2.2 Deco-Touch .............
For more information about their operation modes refer to the Main and auxiliary wall control User Guide, VD0278 included with the ventilation unit and also available at www.vanee.ca or www.venmar.ca. Would you like to receive occasional informational e-mail off ers including Aimeriez-vous recevoir plus de détails sur nos promotions, off...
For the User 2. USER SERVICING INSTRUCTIONS 2.1 Q UARTERLY AINTENANCE ⚠ WARNING • Risk of electric shock. Before performing any maintenance or servicing, always disconnect the unit from its power source. • When cleaning the unit, it is recommended to wear safety glasses and gloves. Unplug unit.
For the User 4. WARRANTY This ventilation unit is a high-quality product, built and packaged with care. The manufacturer warrants to the original purchaser of its product, that such products will be free from defects for the period stated below, from the date of original purchase. For all units, the warranty covers parts only against any operational defect.
For the Installer CAUTION • Before installing this unit, please take the time to carefully read page 2 of this guide to ensure it is installed safely and properly. • For Novoclimat compliant installation requirements, please refer to the current Novoclimat Program criterias. 5.
For the Installer 6.3 I NSTALLING THE UCTWORK AND THE REGISTERS ⚠ WARNING • Never install a stale air exhaust register in a closed room where a combustion device operates, such as a gas furnace, a gas water heater or a fireplace. •...
For the Installer 6.3.4 S IMPLIFIED NSTALLATION ETURN UPPLY CAUTION 18” (0.5 When performing duct connections to the furnace supply MINIMUM duct, use metal ducts appropriately sized to support the additional airflow produced by the unit. Stale air exhaust ductwork: •...
For the Installer 6.5 C ONNECTING THE DUCTS TO THE CAUTION • If ducts have to go through an unconditioned space (e.g.: attic), always use insulated ducts. • Make sure the vapor barrier on the insulated ducts does not tear during installation to avoid condensation within the ducts.
For the Installer 6.6 C ONNECTING THE RAIN Cut 2 sections of plastic tubing of at least 12” each. Connect each one of them to the inner drain fittings located under the unit. Join their other ends to the "T" junction and remaining tubing as illustrated. This will prevent the unit from drawing unpleasant odors from the drain source.
For the Installer 7.2.1 A 7.2.2 D LTITUDE OR LATINUM OUCH NO C NC I OC OL Y R G B NO C NC I OC OL Y R G B MODE SMART PREF VE0181 VE0250 7.2.3 L 7.2.4 C OUCH ONSTRUCTO IMPLE...
For the Installer 9. BALANCING THE UNIT REPARATION Follow these steps to ensure accurate measurements: • Seal all the ductwork with tape. Close all windows and doors. • Turn off all exhaust devices such as range hood, dryer and bathroom fans. •...
Page 15
For the Installer Part Item Description Hinge assembly kit 13036 Damper supply port assembly 17245 Damper system actuator 17235 (incl. no. 4) Thermistor kit 17242 Capacitor 7.5 μF 17240 60809 Electronic board 60810 Transformer 17244 Double collar port 60818 60804 Blower assembly (incl.
For the Installer 11. WIRING DIAGRAM ⚠ WARNING • Risk of electric shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source. • This product is equipped with an overload protection (fuse). A blown fuse indicates an overload or a short-circuit situation. If the fuse blows, unplug the product and check the polarity and voltage output from the outlet.
For the Installer 12. TROUBLESHOOTING If the integrated LED of the unit is flashing, the unit sensors detected a problem. See the table below to know more about the nature of the problem. LED Signal Error Type Action LED flashes GREEN (double blink) Thermistor error Replace the thermistor kit.
Page 18
Service technicians only: If you require assistance or have questions after performing the following troubleshooting, call : HRV CONSTRUCTO 1.5ES HRV SOLO 1.5ES HRV NOVOFIT 1.5ES 1-800-649-0372 HRV CONSTRUCTO 2.0ES HRV SOLO 2.0ES HRV NOVOFIT 2.0ES 100H 200H NOVO+ 100H...