RTC Battery
30
GFK-2898B
For public disclosure
➢ ➢ To replace the RTC battery
Remove power from the RXi Display by disconnecting the power cable.
1.
2.
Loosen the six captive screws on the back of the RXi Display that are holding the
RTM and gently lift the RTM away from the display panel.
Loosen the four captive screws that are holding the two RTM sections together and
3.
gently separate without stretching the internal power cable. Disconnect the internal
power cable and place the RTM chassis with interior lid on a static-safe surface.
4.
Remove the four Phillips-head screws that secure the interior lid to the RTM chassis,
and lift off the interior lid.
Remove the RTC battery from the retaining clip. Do not use any metallic item to
5.
remove the battery, including screwdrivers, knives, pliers, and such.
Caution
Attention
RTC Battery Location
Be careful to not bend the positive terminal clip on
the battery holder.
Dispose of used batteries in accordance with the
instructions provided in the Battery Disposal
document, 82A1540-MD01.