Grounding; Connecting The Flexbus Cable - Nokia MetroHopper User Manual

Radio with fc rri/fxc rri
Table of Contents

Advertisement

5.1

Grounding

The radio section must be connected to an external grounding electrode
immediately after installation. The grounding wire is of type 16 mm
To connect the grounding wire:
1.
2.
3.
Caution
Make sure that general grounding is performed according to regulations issued by
the local authorities.
5.2

Connecting the Flexbus cable

A clamp-type (watertight) straight TNC connector fitted into, for example, RG−
223 cable can be used to connect the IU and the OU. Leave the cable slack enough
to allow the outdoor unit to be turned during the alignment. It is advisable to label
the cables (for example with the hop ID) in order to facilitate identification later.
In case the cables are completed on site, protect the connectors from water with
adhesive tape or shrink-on wrapping. The ready-made cables have a shrink-wrap
protection.
Caution
If the cable is already connected to the indoor unit, make sure the Flexbus OU
power supply is switched off before connecting the cable to the outdoor unit.
Power can be switched off using the manager software.
24 (26)
© Nokia Networks Oy
Peel the tip of the grounding wire (15 mm).
Connect the grounding wire to the grounding clamp of the outdoor unit and
tighten the M6 screw.
Connect the other end of the grounding wire to the general grounding wire
or bar of the installation pole.
Installation
2
Cu.
DN99592289
Issue 2-1 en