Reference and Sequencing
Speed potentiometer: 1 (Low), 4 (High),
2 (Wiper) OR
External speed reference: 1(-) and 2(+)
Start contact between 6 and 7
Jog contact between 6 and 9
Reverse Direction contact between 6 and 8
Calibration
All calibration is done in software, through the keypad.
SAVING
Changes
take effect
as soon as
they are
entered and
parameters
are saved
automatically
in a few
seconds
Cloning
The 650X drives may be cloned using the 6514 Clone
option that plugs into the keypad slot. Settings include
to/from, I/O configuration and full/part transfer.
Serial Comms
The 6513 Serial Communication option can be
plugged into the keypad slot. It can be used to exchange information between the Master and Slave drives in
RS485/232 format, up to 32 units can be connected together. Front panel LED indicators provide status and
health indication.
+44 (0)117 938 1800 - info@sdsdrives.com
650V & 650G only
Power-up
screen
SETUP PARAMETERS
P1
Application Select Select the application macro
P2
Max Speed
P3
Min Speed
P4
Acceleration time
P5
Deceleration time
P6
Motor Current
P7
Base Frequency
P8
Jog Setpoint
P9
Stop Mode
P11 V/Hz shape
P12 Overload Rating
P13 Fixed Boost
P99 Password
POWER ON
d1
Frequency
d2
Speed Setpoint
d3
DC Link Volts
d4
Motor Current
The drive powers up in
red buttons to start/stop and the up/down arrows to adjust
speed. To switch to
button down until
rdy
MODE:
At the
Set max speed in Hz
Set min speed in %
Accel time to Max Speed in sec
Decel time from Max Speed in sec
Motor full load current in amps
Motor nameplate frequency in Hz
Set jog speed in % of max speed
0=Ramp; 1=Coast; 2=Injection braking
0=Linear; 1=Quadratic (fan or square)
0=150% for 30s.; 1=110% for 10s.
Set boost in % volts (V/Hz mode only)
Set from 0001 to FFFF for protection
If using three wire control
Start button (n.o.) between 6,7
Stop button (n.c.) between 6,10
650V & 650G only
DIAGNOSTICS
Output frequency (Hz)
Speed SP (% of Max Speed)
Voltage of DC Bus
Motor Current (amps)
LOCAL MODE.
REMOTE MODE,
L0C
disappears. To revert to
screen, push STOP until
1-4
Use the green/
hold the STOP
LOCAL
L0C
appears.