  • Page 1 7 Day Digital Programmer 1 Channel – Surface Mount Model: TRT034N...
  • Page 2: General Information

    1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety • Before installation or maintenance, ensure the mains supply to the Programmer is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
  • Page 3 • CE Compliant • Dimensions (H x W x D): 90 x 135 x 30mm TRT034N Front View The heating symbol will show Display light/Holiday 1, 2 and 3 hour boost when heat is demanded...
  • Page 4: Installation

    4. Siting • The TRT034N should be located at a position which eases wiring runs and gives good access for Programming. • It should be mounted approximately 1.5m above floor level. 5. Installation 5.1 Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
  • Page 5 TRT034N Wall Plate Alternate mounting holes Retaining tabs Mounting holes Loop terminal Wall plate retaining screws...
  • Page 6: Connection Diagram

    6. Connection Diagram Connect the 230V 50Hz mains supply and load cables to the terminal block which are marked as follows; • Note: Check boiler instructions before connecting. Switch Live from NO (normally open contact for heating) to Boiler BOILER 230V AC 50Hz Supply Supply...
  • Page 7: Dip Switch Settings

    DIP switches in the correct position on the rear of the unit. A reset will be required after changing the DIP switch positions. TRT034N Rear of Unit DIP switches for 5-2 or 7 day Programming...
  • Page 8: Setting The Time And Date

    8. Reset from Power-up • Restore mains to the unit after making sure to check all system wiring is complete, and after you have selected the desired DIP switch settings. • Press the reset button located beneath the flip down cover on the front of the unit, all of the characters will briefly appear on the display, followed by the 12hr clock format screen.
  • Page 9 9.3 Use the Up/Down arrow buttons to either select 24Hr format, or leave it at 12Hr format, and then press the Select button once to confirm. 12Hr AM/PM format Use the Up/Down arrow 24Hr format Use the Select buttons to change button to the time format confirm...
  • Page 10 9.7 The month will flash, use the Up/Down arrow buttons to alter the year and press the Select button once to confirm. The month will flash Use the Up/Down Use the Select arrow buttons to button to change the month confirm 9.8 The day will flash, use the Up/Down arrow buttons to alter the day and press the Select button once to confirm.
  • Page 11 10. Programme Entry Note: • If you have selected weekday/weekend (5-2) Programming via the DIP switches (see section 7. DIP Switch Settings) you will be able to group Monday – Friday for the same ON and OFF times, and then group Saturday – Sunday for the same ON and OFF times. •...
  • Page 12 10.3 The P1 ON (Programme 1 ON) hour will flash, use the Up/Down arrow button to choose the hour and press the Select button once to confirm. The hour will flash Use the Up/Down Use the Select arrow buttons to button to change the hour confirm...
  • Page 13: Copy Function

    • Unwanted days of the week need to be entered as the same time i.e. Wed P1-P2-P3 ON 7:00AM, P1-P2-P3 OFF 7:00AM. Thu P1-P2-P3 ON 7:00AM, P1-P2-P3 OFF 7:00AM etc. • The Set button can be pressed twice to exit the programme entry at any stage.
  • Page 14 10.13 Use the Up/Down arrow buttons to choose the day of the week you wish to copy the Programme to e.g. Tue, and press the Select button once to confirm. Use the Up/Down arrows to Copy and the day of Use the Select button choose the day you wish to copy the week will flash...
  • Page 15: Operation

    11. Operation Programme Modes • There are 4 Programme modes available. You can cycle through all 4 Programme modes by pressing the Advance and Mode Copy button. The output status will be as follows; Press the Advance and Mode Copy button to cycle through the 4 Programme modes.
  • Page 16: Boost Function

    Boost Function • The boost options are 1 hour, 2 hours, 3 hours and 0 hours to cancel. • Press the Boost button once for 1 hour, the display light will illuminate as well as the Boost button surround. While setting, and during the boost period, the On flashes ON and OFF.
  • Page 17: Holiday Mode

    Display Light/Holiday Button • Pressing the Display light/Holiday button once illuminates the display for 15 seconds. • Any key press will illuminate the screen also, with a 15 second time out after the last button press. • Any time the back light is on, the Display light/Holiday button surround illuminates.
  • Page 18 • The holiday duration will be displayed in the top right had corner of the screen. Holiday duration Suitcase symbol • To cancel the holiday, press the Display light/Holiday button and hold for 3 seconds. The holiday duration and suitcase symbol will disappear.
  • Page 19: Year Guarantee

    020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs...
  • Page 20 If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline @ timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.

Table of Contents