Outside the United States and Canada, in regions with 230 V supply voltage:
If you do not use the safety-certified power cable, use a flexible, double-insulated power
supply cable (no single cables) with the following characteristics:
● At least 18 AWG (0.75 mm
● Grounded safety plug 15 A, 250 V
Note
Ensure that the cable set conforms to the respective national safety regulations and is
appropriately labeled.
For USA and Canada:
A CSA or UL-listed power supply cable must be used in the United States and Canada.
120 V power supply
Use a flexible cable with the following characteristics:
● UL approval
● CE marking
● Type SJT with three conductors
● At least 18 AWG (0.75 mm
● Maximum 4.5 m length
● Parallel grounded safety plug 15 A, min. 125 V
230 V power supply
Use a flexible cable with the following characteristics:
● UL approval
● CE marking
● Type SJT with three conductors
● At least 18 AWG (0.75 mm
● Maximum 4.5 m length
● Tandem grounded safety plug 15 A, min. 250 V
IFP, IFP PRO, IFP ETH
Operating Instructions, 11/2017, A5E31298376-AH
) conductor cross-section
2
) conductor cross-section
2
) conductor cross-section
2
Installing and connecting the device
3.4 Connecting the device
63