Download Print this page
Festo VZWP-L-M22C Series Operating Instructions
Festo VZWP-L-M22C Series Operating Instructions

Festo VZWP-L-M22C Series Operating Instructions

Solenoid valve

Advertisement

Quick Links

Solenoid valve
VZWP-L-M22C
Operating instructions
Original: de
Solenoid valve VZWP-L-M22C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
Design
4
3
2
1
1
Port 1: Input
2
Valve body
3
Electrical plug connector with seal
and mounting screw
4
Knurled nut
5
O-ring
Fig. 1
2
Function
The solenoid valve VZWP–L–M22C is a servo controlled
2/2-way valve with solenoid coil.
The solenoid valve VZWP–L–M22C is closed when de-ener­
gised (Normally Closed - NC). When power is supplied, the
differential pressure is relieved from the secondary side of
the piston via the servo hole. The effective differential pres­
sure lifts the piston away from the valve seat.
The pilot function of the valve actuator can be used to control high pressures with
large nominal diameters by means of small solenoid coils.
The minimum differential pressure must always be present to ensure smooth func­
tioning of the servo control (è Technical data).
Festo AG & Co. KG
Postfach
73726 Esslingen
Deutschland
+49 711 347-0
www.festo.com
8065870
1611a
[8065872]
English
6
Solenoid coil
7
O-ring
8
Armature guiding tube
9
Port 2: Output
aJ
Arrow for flow direction
aA
Thread for mounting bracket
Fig. 2
3
Application
Solenoid valves of the series VZWP–L–M22C are intended to control the flow of
gaseous and fluid media in rigid piping systems.
• The product may only be used in its original state without unauthorised modific­
ations. Only the mounting and commissioning activities described in these oper­
ating instructions are permissible. Do not open the valve body or dismantle the
armature guiding tube.
• Do not use the product in closed circuits.
• Do not use the VZWP solenoid valve as a safety component.
• Use the product only in perfect technical condition.
• Only use media in accordance with specification. Before using other media,
please contact our customer support.
• Operation with chemically unstable gases, abrasive media and solids is imper­
missible.
• Use the solenoid valve only in the marked flow direction.
Return to Festo
Hazardous substances can endanger the health and safety of personnel and cause
damage to the environment. To prevent hazards, the product should only be re­
turned upon explicit request by Festo.
– Consult your regional Festo contact.
– Complete the declaration of contamination and attach it to the outside of the
packaging.
– Comply with all of the legal requirements for the handling of hazardous sub­
stances and the transport of dangerous goods.
4
Product variants
Features
Type
Valve type
Valve function
Connection to valves and fittings
5
Nominal size (DN)
6
Sealing material
Nominal voltage
7
Electrical connection
Operating pressure
Fig. 3
8
5
Transport and storage
• When shipping used products: Comply with all legal requirements for handling
hazardous substances and transporting dangerous goods.
For return to Festo è Kapitel 3.
9
• Store the product in a cool, dry, UV- and corrosion-protected environment.
aJ
6
Installation
aA
Note
• Installation only by qualified personnel.
• Avoid contamination. In this way you will prevent small holes from becoming
blocked (e.g. servo hole) and restriction or blockage of the function.
• Avoid mechanical stresses especially on the solenoid coil and the armature
guiding tube.
• Ensure sufficient thermal circulation at the installation location.
1. Before installation, check the system requirements:
– The tubing system is unpressurised and does not hold any medium.
– The pipelines are clean.
– The ends of the pipelines are mounted.
– The power supply is switched off.
2. Put the solenoid valve in its mounting position. Please note the flow direction.
The permissible flow direction is marked by an arrow on the valve body.
3. Screw the ends of the pipelines to the valve ports. Observe the permissible
tightening torques.
4. Establish the electrical connection. Use only the specified plug type (è Tech­
nical data).
– Connect the electrical cable to the plug connector.
– Attach the seal to the electrical contacts.
– Plug in the plug connector and secure it in place with the mounting screw
(torque 0.3...0.5 Nm).
5. Connect the power supply.
Type code
Description
VZWP
Solenoid valve, servo controlled
L
In-line valve
M22C
2/2-way valve, normally closed (NC)
G14 to G1
Pipe thread per DIN ISO 228
N14 to N1
NPT pipe thread per ANSI B 1.20.1
130
13 mm
250
25 mm
NBR
V
FPM
1
24 V DC
2A
110 V AC (50-60 Hz)
3A
230 V AC (50-60 Hz)
P4
Plug socket, 3-pin
40
Max. 40 bar

Advertisement

loading
Need help?

Need help?

Do you have a question about the VZWP-L-M22C Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Festo VZWP-L-M22C Series

  • Page 1 Transport and storage • When shipping used products: Comply with all legal requirements for handling hazardous substances and transporting dangerous goods. For return to Festo è Kapitel 3. • Store the product in a cool, dry, UV- and corrosion-protected environment. Installation Note •...
  • Page 2 Commissioning Eliminating malfunctions Malfunction Possible cause Remedy Note Solenoid valve Solenoid valve is defective. • Replace the solenoid valve. not closing • Commissioning only by qualified personnel. Flow direction is incorrect • Install the solenoid valve in accord­ ance with the flow arrow •...