Signal Extraction Pulse Oximeters O P E R A T O R ’ S M A N U A L...
Page 2
The Rad-8 Operating Instructions provide the necessary information for proper operation of all Rad- 8 pulse oximeter models. General knowledge of pulse oximetry and an understanding of the features and functions of the Rad-8 pulse oximeter are prerequisites for its proper use.
Page 3
SAFETY INFORMATION, WARNINGS, CAUTIONS AND NOTES ■ The Rad-8 Compact pulse oximeter is designed to minimize the possibility of hazards from Do not place the pulse oximeter on electrical equipment that may affect the pulse errors in the software program by following sound engineering design processes, risk analysis oximeter, preventing it from working properly.
A WARNING is provided when actions may result in a serious outcome (i.e., injury, The Rad-8 family consists of two models: the vertical Rad-8 and the horizontal Rad-8. serious adverse affect, death) to the patient or user. Look for text in a gray shaded box.
P u l s e O x i m e t r y FUNCTIONAL VS. FRACTIONAL SATURATION The Rad-8 is calibrated to measure and display functional saturation which is the amount of GENERAL DESCRIPTION oxygenated hemoglobin expressed as a percentage of the hemoglobin that can transport Pulse oximetry is a continuous and non-invasive method of measuring the level of arterial oxygen.
All user input is handled by control buttons Pulse Oximetry) Post on the front panel and the sensor cable connection is located on the left side of the Rad-8 Processor horizontal and the bottom of the Rad-8 vertical.
The AC Power Charging indicator is illuminated when Mode / Enter Used to enter the setup menus and to select/activate cer- Charging the Rad-8 is connected to AC line power and the bat- Button tain entries within the menu/setup system. Indicator tery is charging.
SYMBOLS R a d - 8 r e a r p a n e l The following symbols are found on the back of the Rad-8 pulse oximeter or packaging and are defined below: SYMBOLS...
I n t r o d u c t i o n Before the Rad-8 pulse oximeter can be used in a clinical setting, it needs to be inspected and properly U n p a c k i n g a n d i n s p e c t i o n Remove the instrument from the shipping carton and examine it for signs of shipping dam- age.
Connect a patient cable or a direct connect sensor to the Patient Cable Connector The green battery charging LED indicator on the unit will remain illuminated while the battery of the Rad-8 pulse oximeter. Make sure it is a firm connection and the cable is not is charging.
■ The violated alarm limit and reading flash on the display. The following table outlines the default values that the Rad-8 reverts to after a power cycle ■ The Visual Alarm Indicator flashes. if not changed by the user: 12.
S u c c e s s f u l S p O 2 m o n i t o r i n g NUMERIC DISPLAY - PULSE RATE The Pulse Rate displayed on the Rad-8 may differ slightly from the heart rate displayed The following general points will aid in ensuring oximetry monitoring success.
(low perfusion). signal quality indicator displayed on the Rad-8 is called the Signal IQ. The Signal IQ can It has been suggested that at extremely low perfusion levels, pulse oximeters can measure be used to identify the occurrence of a patient’s pulse and the associated signal quality of...
Mode/Enter or Next keys are pressed. During normal operation, the Rad-8 Display shows oxygen saturation (as % SpO ) and NOTE: The Rad-8 will automatically ‘time out’ of the setup menu after 10 seconds with no Pulse Rate (in beats per minute). key presses.
Low Signal IQ Type when Mode Enter or The Rad-8 only stores data in the trend memory while the device is turned on, and the Alarm Next are pressed. trend data remains in memory until the memory fills up or cleared by the user.
Philips/Agilent monitor. Please see the Philips/Agilent VueLink format to the serial port Operator’s manual for complete instructions. The Rad-8 pulse oximeter can be set up to audibly indicate all patient alarms while MENU ITEMS DESCRIPTION communicating with the Philips/ VueLink module.
3 seconds set/selected ation. when Mode A serial cable is required to connect the Rad-8 to a PC. Patient monitoring is not possible Press to toggle to Enter or Next are while trend memory is being transferred to a PC.
ALARM TYPE PRIORITY gathering data on a new patient, it is highly recommended the "clear function" be utilized in order for the results to be separate. Turning the Rad-8 off will not erase the trend data. Low saturation (SpO range 1-100%)
Alarm Suspend Mode. ALARM SILENCED INDICATOR SETTING RANGE The Alarm Silenced Indicator provides visual feedback when illuminated, the Rad-8 audible The SpO high alarm limit can be set anywhere between 2% and 99%, alarms are muted.
T r o u b l e s h o o t i n g The Rad-8 will indicate other data or system errors. The following chart describes what to do if the Rad-8 system does not operate properly Message conditions for the Rad-8 follow: or fails.
41°F to 104°F (5°C to 40°C) Transportation/Storage Temperature: -40°F to 158°F (-40°C to +70°C) Operating/Storage Humidity: 5% to 95%, non-condensing 500 mbar to 1060 mbar pressure, Operating Altitude: -1000 ft to 18,000 ft (-304 m to 5,486 m) Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual...
Continuous No Connection 1 Masimo SET technology with LNOP Adt/ Neo sensors has been validated for no motion accuracy in human blood studies on healthy Signal Ground Reference for COM signals adult male and female volunteers with light to dark skin pigmentation in induced hypoxia studies in the range of 70-100% SpO against a laboratory co-oximeter and ECG monitor.
Directions for Use to ensure skin integrity and correct positioning and adhesion NURSE CALL of the sensor. The nurse call feature on the Rad-8 pulse oximeter is based on the relay closing or open- CAUTIONS: ing depending on alarm, Low Signal IQ events or both. In addition the nurse call polarity ■...
ILIZE ANY MASIMO SENSOR BY IRRADIATION, STEAM, OR ETHYLENE OXIDE. M a s i m o S E T p a t i e n t c a b l e s Reusable patient cables of various lengths are available. Only use appropriate Masimo oximetry patient cables for SpO measurements.
HARSH SOLVENTS, TO CLEAN THE OXIMETER. THESE SUBSTANCES ATTACK THE DEVICE’S MATERIALS AND DEVICE FAILURE CAN RESULT. Refer to Section 8, Cleaning and Reuse of Masimo Sensors for cleaning instructions of the sensor. Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual...
Set the SpO low alarm limit to 90 (see Section 4, Setup Menu Level 1 - Alarm maintenance, follow the procedure outlined in this section. If the Rad-8 fails any of the Limits and Alarm Volume). described tests, discontinue its use and correct the problem before returning the unit back...
W a r r a n t y REPAIR POLICY Masimo warrants to the initial purchaser that each new pulse oximeter will be free from Masimo or an authorized Service Department must perform warranty repair and service. defects in workmanship or materials for a period of one (1) year from the date of purchase.
13260 Rad-8 Operators Manual, Portuguese not be transferred to anyone, except other end-users, without the prior written con- sent of MASIMO. In no event may you transfer, assign, rent, lease, sell, or otherwise 30955 Rad-8 Operators Manual, Chinese dispose of the software/firmware or the products on a temporary basis.