L8542910 04/2011 rev. 1 BRAINY UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI...
Page 2
Fig. 1 BRAINY R A D I O SHIELD STOP PHOT (Close) PHOT CLOSE AUX2 OPEN PED. P.P. J2 DAS SWC-M2 (Close) Close DAS 8K2 SWO-M2 (Open) SWC-M1 (Close) SWO-M1 (Open) J2 DAS 24Vac AUX1 Open Lock DAS N.C. 500mA max...
The electrical installation and the operating logic must comply with the regulations in force. TECHNICAL DATA Mains power supply 230 VAC 50/60 Hz (115VAC 50/60 Hz for BRAINY 115) Output, Motor 1/2 motor, 230Vac (1/2 motors 115 Vac for BRAINY 115) Motor maximum power...
Page 5
BRAINY CONTROL UNIT INPUT/OUTPUT FUNCTIONS N° Terminals Function Description 1-2-3 Power supply Input 230Vac 50Hz (1-GND/2-Phase/3-Neutral) 4-5-6 Motor 1 Connection of motor 1: (4-start/5-Com/6-start) 7-8-9 Motor 2 Connection of motor 2: (7-start/8-Com/9-start) 10-11 Blinking light Connection of blinking light 230Vac 40W max.
Page 6
4 - With the <+> or <-> button, select the function you want. 5 - Press the button <PG>, the display shows the value currently set for the function selected. 6 - With the <+> or <-> button, select the value you intend to assign to the function. 7 - Press the button <PG>, the display shows the signal “PRG”...
Page 7
Valori impostabili MENU FUNZIONE MEMO ON-OFF-(Default) The intervention threshold of the anti-crashing device (Encoder) during the phase at SeaU normal speed is adjusted.* 0-99-(0%) 0:Off-1:minimum sensitivity - 99: maximum sensitivity The intervention threshold of the anti-crashing device (Encoder) during braking is SEAR adjusted *.
Page 8
Settable values MENU FUNCTION MEMO ON-OFF-(Default) Enables or disables Man present function. On: Man Present operation. (OFF) The OPEN/CLOSE buttons must be held down during the whole manoeuvre. Off: Automatic operation. The calculation of residual operating time is activated or deactivated in the event of partial operations: On: Calculation of deactivated time.
Page 9
MENU FUNCTION By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the step-by-step function. Press the transmitter key, which is to be assigned to this function. If the code is valid, it will be stored in memory and OK will be displayed. If the code is not valid, the Err message will be displayed.
Page 10
BRAKING With the ENC=OFF logics, braking is given by the TSM1/TSM2 parameter value referred to the TM1/TM2 operating time. For example, if the operation of motor 1 lasts 20 seconds and TM1=24s and TSM1=8 are preset, 4 s braking will result (20-(24-8). With ENC=ON logics, braking is calculated as a percentage on the space covered during the complete operation.
Page 11
DIAGNOSTICS In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, SWO-M1 SWO-M2 control and safety) can be displayed. One segment of the display is linked to each input. SWC-M1 SWC-M2 In the event of failure it switches on according to the following scheme. P.P.