Preparation; Checking The Instrument Code Number - ABB C1900 series User Manual

Circular chart recorder and recorder/controller
Hide thumbs Also See for C1900 series:
Table of Contents

Advertisement

3 PREPARATION

3.1 Checking the Instrument Code Number – Table. 3.1
Part 1 – General Details
1900 Recorder,Recorder/Controller
Dairy/Pasteurization Variants
Safety Thermal Limit Recorder (STLR), Two pens (Red
and Green) plus True Time Event Pen (Violet), Taylor
ER/C charts
Recorders and
Chart Type
Safety Thermal Limit Recorder (STLR), Two pens (Red
and Green) plus True Time Event Pen (Violet),Kent
PX105 charts
High Temperature Short Time (HTST) Recording Controllers
(HTST) One Control Unit, Two Pens (Red and Green),
Plus True Time Event (Violet), Taylor ER/C charts
(HTST) One Control Unit, Two Pens (Red and Green),
Recorder/
Plus True Time Event (Violet), Kent PX105 charts
Controllers
and Chart Type
(HTST) Two Control Units, Three Pens (Red, Green and
Blue), Plus True Time Event (Violet), Taylor ER/C charts
(HTST) Two Control Units, Three Pens (Red, Green and
Blue), Plus True Time Event (Violet), Kent PX105 charts
Standard
Electrical Code
CSA
None
Option Module
Additional Modules – Part 2 below
Options
None
Not Fitted
Door Lock
Fitted
115V AC
Power Supply
230V AC
24V AC
Part 2 – Additional Modules
1952 Enter code 1 for optional cold product module
Module
1951 and 1953 Enter code 0 cold product module
Position 2
always fitted
Module
1952 and 1953 Enter code 0, hot water module always fitted
Position 3
1951 No option permitted
Module
Enter code 1 or 2 for auxiliary input module
Position 4
For other options see key below
Module
Enter option 9 fop FDA dairy applications (115V only)
Position 5
For other options see key below
If option 9 is selected is selected above, no other option
Module
is permitted
Position 6
Company Standard
Special
Customer Setting
Settings
Special
All units are provided with a True Time Event Pen as standard.
Key to Module Types
0 No module fitted
1 Standard Input/Output
2 Analog Input plus Relay
3 Four Relays
4 Eight Digital Inputs
Table 3.1 Code Number Interpretation
5 Eight Digital Outputs
8 MODBUS RS485 Communications
(MODBUS configurator must be set to READ only)
9 Dairy Relay Board (takes module positions 5 and 6), 115V only
Refer to Fig. 4.1 for module positions and identification.
19 XXX
X
X
0
X
X
51J
51K
52R
52S
53R
53S
A
B
0
A
0
1
2
1
2
3
0
1
0
0
1
2
3
4
5
0
2
3
4
0
2
4
5
X
0
X
X
X
XXX
9
8
STD
CUS
SXX
5